Comfort Stat BLU2810 Скачать руководство пользователя страница 2

heat 

off

cool

system

auto

Mon

HEAT

AM

1

efficiency. Note that it is easier to modify these programs

 

than to programs than to 

program the thermostat manually. 

 

 Press once. During Auto Programming, the display 

will change as shown.   

 The thermostat will be programmed for all 7 days of 

the week as shown below. 

 Temperature 

in 

˚

F/

 

Program Number 

Time 

Heat 

Standard 

1 6:00am 

68 

˚

F  (20

) 78 

˚

F  (26

2 8:00am 

60 

˚

F  (16

) 85 

˚

F  (29

3 4:00pm 

68 

˚

F  (20

) 78 

˚

F  (26

4 10:00pm 

60 

˚

F  (16

) 85 

˚

F  (28

    Refer to Manual Programming entering or changing the programs. 

 
PROGRAMMING  

Before programming or changing program, use this Personal 
Program Schedule to determine which time and temperature 
Settings will best satisfy both your comfort and energy saving requirements. Use a pencil 
so you can revise yours records each time you change your temperature settings.                     

Heating 

DAY Program1 Program2  Program3 

Program4 

Mon. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Tue

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Wed. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Thu

Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Fri. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sat. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sun. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Cooling 

DAY Program1 Program2  Program3 

Program4 

Mon. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Tue. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Wed. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Thu. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Fri. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sat. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Sun. Time 

Temp 

Time 

Temp 

Time 

Temp 

Time 

Temp 

Manual Programming   

 Your thermostat can be programmed for weekdays and weekends, or have unique 

programs for all 7 days. Use Weekday /Weekend Programs or 7-day Programming to 
enter or revise programs to match your Personal Program Schedule. The same steps 
are used when entering programs for the first time, or revising programs entered during 
Auto Programming. 

 Familiarize yourself with Manual Programming, so that you can easily modify your 

programs as your comfort needs change. The example below demonstrates the Manual 
Programming method. 

NOTE:  

1

The program time can be set in 15-minute increments, and remains the same for both 

Heat and Cool programs.   
2

The program temperature can be set in increments of 1

˚

F (1

˚

C). 

3

The Heat setpoint can not be set higher than the Cool set point, and the Cool 

set point can not be set lower than the Heat set point. 
4

If the system selector is in AUTO mode, the current operating mode will be used for 

programming. 
5

After 15 seconds without a key press, the thermostat will return to normal display 

mode. 
6

When setting the program time, note the AM/PM indicator. 

7

With the Auto Recovery feature enabled, you do not need to set your comfort program 

times early. Auto Recovery will determine how early Recovery will determine how early 
to turn your system on, so that the room is comfortable at the program time. 
8 .”PROG”,”PROG DAY” keys do not work with non-program mode. 

Weekday/Weekend Programming 

 

Step 1     

Slide System Selector Switch to HEAT or   

COOL to program the corresponding system. 
NOTE: If the system selector is in the OFF position, no 
programming is permitted. The LCD display will show only dashes 
when the program key is pressed. 

Step 2               

 

Press it to enter program mode, 

Display shows weekday programs and Program   
hour are flashing . 

 

Display for HEAT mode shown. 

 

Step 3 

.Use        and      to change the hour. 

Step 4   

Press PROG again to change to the minute position the   
current minute will be flashing. 
 

Step 5 

. Use        and      to change the minute. 

 

Step6  

Press PROG again to change to the program temperature, 

the current program temperature will be flashing. 

 

Step 7

  Use        and      to change the temperature. 

 

Step 8               

Press it to change the weekend program.   

Repeat Step 3 and 6 to complete the 

weekend programs.   

 

Step 9        

Press to to normal mode after 15 seconds, the thermostat will return to 
normal mode automatically. 

 

Step 10                         

 Change the System Selector Switch to the other system. And 

repeat Step2 through 9 above. 

 

7-DAY Programming   

 

Step 1                           

 Slide System Selector Switch to HEAT or 

     COOL to program the corresponding system. 

 
Step 2                       

 Press to enter program mode, display shows 

Monday programs and 

Program

 

hour are flashing . 

 

Step 3 

.Use        and      to change the hour. 

Step 4   

Press PROG again to change the minute position the   
current minute will be flashing. 
 

Step 5 

.Use        and      to change the minute. 

 

Step6  

Press PROG again to change to the program temperature 

 

Step 7 

.Use        and      to change the temperature. 

 

Step 8               

Press it to change the next program number.   

Repeat Step 3 and 6 to complete the remaining Weekday and 

 Weekend programs.  

 

Step 9        

Press it to normal mode or after 15 seconds, the thermostat will return 
to normal mode automatically. 

 

Step 10                         

 Change the System Selector Switch to the other system. And 

repeat Step2 through 9 above. 

                                                                                                                                                                 
Reviewing Programs 

You may want to review the programs to confirm that the settings are compatible with 
your lifestyle. 
 
Use        and         to review the programs. 
 

NOTE

: Programs affect as soon as the thermostat returns to normal mode. 

If you are armchair programming the thermostat, slide the system selector   
to the OFF position before mounting the thermostat to the wall plate. 

Reviewing the Current Temperature Setting     

Current time and temperature. 

 

Press it for 1 second or less. 

Set Temperature is shown above current room temperature. 

 
 

OPERATION 
System Selector Switch   

The System Selector Switch on the front of the thermostat determines   
the Operating mode of the thermostat. You may select COOL ,OFF ,     
HEAT, AUTO. In order to take full advantage of this thermostat’s 
feature, we recommend using the AUTO mode. Refer to the Auto Season Changeover 
information on Auto Season Changeover. 

NOTE

: Anytime you install or remove the thermostat form the wall plate, slide the 

System Selector to the OFF position to prevent the possibility of a rapid system On-Off. 

Fan Switch 

The Fan switch should normally be located in the AUTO position. The Fan 
will be turned on along with normal operation of your system. In a normal   
gas or oil furnace, the Fan will be turned on by your furnace after its warm-up   
delay. For electric heat, air conditioning, and heat pump operation, the Fan will turn on 
with the system. To run the Fan on continuously, slide the Fan switch to the ON position.   

Temporary Manual Override   

To temporarily change the current set temperature without affecting your program:   
 

 Press and hold      or       for less than 1 second to enter Manual Override 

mode.. 
   

 Press       and       to change to your desired new temperature. 

 

 Press to RUN to normal mode or wait 15 seconds for it to return automatically. 

 The current program number will flash to signify the Temporary Override. 

At the next program change, the Temporary Override is canceled, and the next 
program temperature becomes the setpoint temperature.   

To end the Temporary Manual Override:   

 Press and wait for HOLD to display on the lcd.

 

 Press HOLD key twice. This will return the set temperature to the current 

program set temperature.   

Permanent Override or a Designated Day Override                                                                           

 

To hold your Manual Override for vacation or Until a Designated Day. 

 Press to make the current program temperature the HOLD 

temperature. HOLD will be displayed on the LCD, and the 
Program number will disappear. 
 

 Follow the Temporary Manual Override instructions above 

to change the Permanent Manual Override temperature. 
 

 

 You can confirm the held set temperature by pressing for less than 1 second. 

 

 Press again. Hold day will be displayed on the lcd and the 

clock will disappear 

Press TIME key to add override days. Press PROG key to 

reduce override days 

 Follow the Temporary a Designated Day Override 

instructions above to change the Permanent Manual Override 
temperature.

 

To end Override:   

Under Permanent Override Press HOLD/RUN key twice. Under a Designated Day 
Override press the hold once. The thermostat will return to the current program, and the 
HOLD display will be canceled. 

Auto Season Changeover 

When the System Selector is in AUTO position , the thermostat will automatically change 
between Heating and Cooling systems, depending on your program. We recommend 
keeping your programmed heating and cooling temperature at least 4

˚

F (2

˚

C) apart to 

allow the Auto Season Changeover to occur when the appropriate temperature span has 
been reached. However, if your heating and cooling programs set temperatures are 
close, there is a built-in program to prevent the thermostat is in Temporary, a Designated 
Day Override or Permanent Override, as these overrides are energy saving settings. 
Auto Season Changeover will still function in Home Today mode, as this is a comfort 
setting. 
For example, you may have the following temperatures programmed at a given time: 
Heat Set Temp=68

˚

F, Cool Set Temp=78

˚

If the room temperature rises above 78

˚

F, then the thermostat will automatically change 

to cool mode and turn on the air conditioner. 
Likewise, the thermostat will automatically change to heart mode and turn on heat when 
the room temperature falls below 68

˚

F. 

HOME TODAY     

This patent pending feature allows you to quickly and Temporarily Override your energy 
saving program setting on days when you are normally away from home with one key 
press. 

 Press and hold 3s to enter the Home Today override .The highest program 

temperature for today will be selected from your programs in 
Heat mode and become the set temperature.(In Cool 
mode ,Home Today will select the lowest program 
temperature for today to be the set temperature.) 

 The display will alternate between “HOME” and the current 

time. 

 When pressed during the day, the thermostat will remain in 

Home Today mode until the first program of the next day. 

If the system is changed between Heat and Cool modes (either manually or by 

Auto Season Changeover) during the “Home Today” override period, the setpoint 
temperature will be automatically update. It will automatically change from the lowest 
cool program setpoint to the highest heat program setpoint.

 

 Press it to exit Home Today mode before the schedule ending time. ”HOME” is 

no longer displayed on the LCD screen, and the thermostat returns to the current 
program. 

 You can manually change the setpoint temperature while in Home Today mode. 

Refer to the Temporary Manual Override instructions .Manually changing the set 
temperature while in Home Today mode will not affect the Home Today ending 
time, However, the set temperature will not change automatically with a manual 
or Automatic change between heating and cooling. 

Energy Monitor

 

 The Energy monitor feature measures and stores the amount 

of time the heating and air conditioning system operates. 
Usage can be display for Today (since 12 am), Yesterday, This 
Week (since Monday), Last Week (last Monday through 
Sunday), and Total (up to 999 Hrs). By monitoring your energy 
usage, you see how much the set-back periods are saving, and 
you can test program adjustment to save even more. To review energy usage, 
press to cycle through Today, Yesterday, this Week, Last Week, and Total. Press 
again to return to normal mode, or wait 15 seconds for the display to return to 
normal mode .You can also return to normal mode at any time by pressing 
HOLD/RUN. 

 For example: This LCD display shows Today’s usage to be 10 Hours, 26 

 minutes. 

 Press and hold for 3 seconds to reset the Energy Monitor’s counters. 

The display will blink, and counters will be cleared to zero. 

NOTE: 

Clearing the Energy Monitor counter will also clear the Filter Monitor counter , as 

Filter usage and Total Energy usage are the same. Also, clearing the filter Monitor 

counter will clear ALL Energy Monitor counters as well. 

Filter Monitor 

Your thermostat also keeps a record of the number of hours your 
filter has been in use. To maximize your system’s performance and 
energy efficiency,change or clear your filter regularly. 

 When the total system run time for heat and cool reaches 400 

hours, you need clean or change your system’s filter, “FILT” will 
continue to flash until the counter is set back to zero. 

 Press ENER key to review total filter usage.   

  In this example, the counter is at 410 Hours, 26 minutes. 

 To reset the Filter Monitor counter, depress ENER for 3 seconds. 

The display will blink, and the counter will be reset to zero. 

NOTE: 

Clearing the Filter Monitor counter will also clear ALL 

Energy Monitor counters, as Filter usage and Total Energy usage 
are the same. Also, clearing the Energy Monitor counters will clear 
the Filter Monitor counter as well.

 

Auto Recovery 

Auto Recovery calculates how early to turn

 

your

 

system back on, so that the room 

temperature is already comfortable by the start of the comfort 
temperature program period. Auto Recovery work’s in both Heat 
and Cool modes.

 

 

When the thermostat is in Auto Recovery mode, the display will 

alternate “RECO” with time, and the program indicator will flash. 

Auto Recovery can be disabled by sliding the Recovery switch on 

the circuit board to disable. 

Auto Recovery will not operate if Permanent hold or Temporary 

hold is in operation. 

Auto Recovery can be canceled manually if

 

HOLD

 

is pressed during the recovery 

process. 

Auto Recovery will be canceled and change to next period. 

Details of Auto Recovery Operation: 

 Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to 

the DISABLE position. 

 Today is in operation. 

 Auto Recovery can be canceled manually if HOLD is pressed during the recovery 

process. If a recovery process is canceled manually then the recovery process will not 
start again until the next program period starts (an exception is that if time or program is 
changed then the thermostat will check Auto Recovery conditions immediately). 

 Auto Recovery will be canceled and change to Home Today mode if HOME TODAY is 

pressed during the recovery process. 

Keyboard lock   

The keyboard can be locked to prevent unauthorized changes to 
the thermostat. 
To lock or unlock the keyboard, press and hold hold/run Key for 3 
seconds.The keyboard is locked.when LOCK appears on the 
display. 

 All keys are locked, Any time a key is pressed, LOCK will appear 

on the display for 1 second. 

Backlighting  

Your thermostat has an electroluminescent lamp that lights the display for easy viewing 
in the dark. 
When any key is pressed the display is illuminated. 
The display will remain illuminated for 8 seconds after the last key is pressed. This 
allows the light to stay on if you need to operate several keys. 

NOTE: 

If the thermostat is in Low Battery warning condition, the backlight will not 

operate. Replace with 2 new AAA alkaline batteries to restore the Backlight function. 

Low Battery Warning 

Your thermostat has a two-stage lower battery warning system. When 
the batteries are first detected to be weak, the first stage low battery 
warning is indicated by “BATT” flashing on the LCD display. At your 
earliest convenience, you need to replace the batteries with 2 new AAA 
alkaline batteries. 
When the batteries become too weak for normal operation, the 
thermostat enters the second stage low battery warning which shuts 
down the thermostat. In this condition, “BATT” flashes alone on the 
display, and the thermostat will turn your system Off. Your system will 
remain shut-off until the batteries are replaced. 

NOTE: 

The thermostat will still keep the current Set Temperature and 

Filter run time in memory until new batteries are installed. After 
confirming that new batteries have been inserted, the thermostat will 
return to normal operation. 

Error Mode

 

If the thermostat is unable to control your system due to an unexpected 
battery problem, the thermostat will enter Error Mode. In this condition, 
the thermostat flashes “E1”,“E2”,”E3”or”E4”on the LCD display, and 
shuts off your system. To correct this problem, replace the batteries with 
2 new AAA alkaline batteries, even if you have recently replaced them. 
Move the battery out, and then hold any key to release the rest energy. 
Then place the battery again. You will need to reprogram your thermostat 
and confirm normal operation. 
If Error Mode returns, please call us for further information. 

LCD display 

Information 

LCD display

Information 

E1

Sensor Error

E3

No use 

E2

System switch 

E4

E2 memory 

Warning Mode 

If the SYSTEM MONITOR SWITCH is close show the system wrong. 
the thermostat flashes “E5”on the LCD display 

Auto Cut Off 

Your thermostat will automatically cutoff in Heat mode if the room 
temperature rises above 95

˚

F (35

˚

C). It will cut off in Cool mode if the 

room temperature drops below 40

˚

F (4

˚

C). 

Note that if your system has malfunctioned and no longer responds 
to thermostat controls, the Auto Cut-Off will have no effect. 

TROUBLESHOOTING  

Problem

     

Solution

 

SCRAMBLED OR 
 DOUBLE DISPLAY 
(numbers over numbers)

1. Remove clear mylar sticker.     

NO DISPLAY 

1.  Check battery connections and batteries 
2. Move the battery out

and then hold any key to 

release the rest energy. Then place the battery again. 

ENTIRE DISPLAY DIMS 

1. Replace Batteries 

PROGRAM DOES   
NOT CHANGE AT   
YOUR DESIRE   
SETTING   

1. Check that the time is set properly to “AM” or “PM”   
2. Check that the thermostat is not in “HOLD” o r “ Home 

 Today” mode. 

3. Check for the correct day settings. 

AUTO/FAN DOES 
NOT TURN

 

ON  

1. Move ELEC/Gas selector to opposite position is in

 

the 

correct position (“HEAT,”COOL” or “AUTO”) 
2. The thermostat may be in the AUTO Mode. Look 
for ”AUTO” on the LCD display. If the Heat and Cool 
program temperature are close, then the thermostat 
requires a larger room temperature change before 
changing from Heat or Cool.   
3. There may be as much as 4 minute delay before the 
Heat or Cool system turns On-wait and check.  
(Compressor protection delay). 
4

Check your circuit breaks and switches to ensure 

there is power to the system. 
5. Replace batteries. 
6. Make sure your furnace blower door is closed   
7. Check the position of the Furnace or Heat Pump 
selector switches: Normal/O/B. 

ERRATIC DISPLAY        1. Move the battery out, and then hold any key to 

release the rest energy. Then place the battery again. 

IF UNIT CONTINUES 
TO OPERATE IN THE 
OFF POSITION      

1. Replace unit 
 

THERMOSTAT 
PERMANENTLY 
READS “E1”,”E2”,”E3”, 
“E4”.. 

1. Replace unit. 
 

 

heat 

off

cool

system

auto

on

auto

fan

EMER

HOLD

RUN

HOLD

RUN

HOLD

RUN

HOLD

RUN

HOLD

RUN

HOLD

RUN

ENER

PROG

DAY

heat 

off

cool

system

auto

heat 

off

cool

system

auto

HOLD

RUN

PROG

PROG

DAY

PROG

HOLD

RUN

PROG

DAY

heat 

off

cool

system

auto

PROG

PROG

DAY

EMER

Отзывы: