Comfort Stat BLU2801 Скачать руководство пользователя страница 2

Mon

HEAT

AM

1

2. Press it to adjust thermostat setting below room temperature. The blower 
should come on immediately on high speed, followed by cold air circulation. 
The display should show “STG1”.   
3. Press it to adjust the temperature setting above room temperature. The 
cooling system should stop operating. 

CONFIGURATION MENU 

INSTALLER/CONFIGURATION MENU 

Step 

 

Press 

Button 

Displayed 

(Factory 

Default) 

Press up or 

down key 

to select 

Comments 

 

ENER 

MS 2 

SS1, HP1 

Selects Single stage, 

Multi-stage, or Heat Pump 

System Configuration 

2 ENER  (SPAN)2 

1,3 

Span(one 

stage) 

3 ENER  (BLIT)on 

off 

BackLight 

4 ENER  (SP2)2 

1,3 

Span(Two 

Stage) 

5 ENER (TEMP)F 

Selects 

temperature 

display °F or °C 

ENER 

HOUR(12) 

24 

Selects time format display 

12hours or 24hours 

7 ENER 

COMP(OFF)  ON 

Selects 

Compressor 

Lockout OFF or ON 

ENER 

COOL(1) 

This model must select 1 

ENER 

FACT(0) 

Select 1,all the setting will 
go back to factory default 

The configuration menu allows you to set certain thermostat operating 
characteristics to your system or personal requirements. Set SYSTEM 
switch to OFF, then simultaneously press up and down keys 3s to enter 
configuration menu. The display will show the first item in the configuration 
menu. The configuration menu table summarizes the configuration options. 
An explanation of each option follows. Press ENER key to change to the 
next menu item. To exit the menu and return to the normal operation, press 
Run Key. If no keys are pressed within fifteen Seconds, the thermostat will 
revert to normal operation. 
1)Single Stage, Multi-stage or Heat Pump System Configuration   
This control can be configured for Heat Pump or two stage heat/one stage 
cool Multi-stage operation. The display indicates “MS 2” (default for 
Multi-stage mode) in the display. The Multi-stage configuration can be 
toggled to “SS1”, or “HP1” by pressing the up or down key. In Multi-stage 
configuration, EMER mode is useless. 
2)Fast or Slow Cycle Selection(one stage) 
3)Select Backlight function OFF or ON 
4) Fast or Slow Cycle Selection(two stage) 
5)Select F° or C° Readout.   
Changes the display readout to Centigrade or Fahrenheit as required 
6) Selects time format display 12hours or 24hours 
7)Select Compressor Lockout COMP OFF or ON 
Selecting COMP ON will cause the thermostat to wait 4 minutes before 
turning on the compressor if the heating and cooling system loses power. It 
will also wait 4 minutes minimum between cooling and heating cycles. This is 
intended to help protect the compressor from short cycling. Some newer 
compressors already have a time delay built in and do not require this 
feature. Your compressor manufacturer can tell you if the lockout feature is 
already present in their system. When the thermostat compressor time delay 
occurs it will flash the setpoint for about four minutes. 
8) This model must select 1 
9)This model must select 1 to back factory Default 

Setting Day and Time                                                                                           

 

y

 The LCD will show this information when batteries 

are first installed. The temperature will update after a 
few seconds. 

y

 During time and day setting mode, the temperature 

displays will go blank. 

y

 Examples: Set the Thermostat to the current time of 9:43 am on 

Saturday.  
Refer to the Steps below. 

STEP 1:                                                                                                                                           

y

 Press to enter time and day setting mode. The 

current hour will be flashing. 

y

 Press up or down to change the Hour up or down 

to the current hour. 
Note the AM/PM indicator, as the display will 
change at 12AM and 12PM. 

STEP 2:                                                                                                                                         

y

 Press again to change from hour setting to minute 

setting. The current minute will be flashing. 

y

 Press up or down to change the Minute up or 

down to the current minute. 

STEP 3:                                                                                                                                                                             

 

y

 Press again to change from minute setting to day 

setting. The current days will be flashing. 

y

 Press up or down to change the Day up or down to 

the current day. 

 

STEP 4:                                                                                                                                         

y

 Press again to change back to the normal display. 

 

Reviewing the Current Temperature Setting     

Current time and temperature. 

 

 Press less than 1 second . 

 Set Temperature is shown above current room temperature. 

OPERATION 

System Selector Switch   

The System Selector Switch on the front of the thermostat 
determines the Operating mode of the thermostat. You may 
select COOL , OFF , HEAT, In order to take full advantage of 
this thermostat’s

 

feature. 

NOTE

: Anytime you install or remove the thermostat form the wallplate, slide 

the System Selector to the OFF position to prevent the possibility of a rapid 
system On-Off. 

Fan Switch 

The Fan switch should normally be located in the AUTO 
position. The Fan will be turned on along with normal 
operation of your system. In a normal gas or oil furnace, the 
Fan will be turned on by your furnace after its warm-up   
delay. For electric heat, air conditioning, and heat pump operation, the Fan 
will turn on with the system. To run the Fan on continuously, slide the Fan 
switch to the ON position.   

Energy Monitor

 

 The Energy monitor feature measures and stores the 

amount of time the heating and air conditioning system 
operates. Usage can be display for Today (since 12 
am), Yesterday, This Week (since Monday), Last Week 
(last Monday through Sunday), and Total (up to 999 
Hrs). By monitoring your energy usage, you see how much the 
set-back periods are saving. To review energy usage, press to cycle 
through Today, Yesterday, this Week, Last Week, and Total. Press 
again to return to normal mode, or wait 15 seconds for the display to 
return to normal mode .You can also return to normal mode at any 
time by pressing RUN. 

 For example: This LCD display shows Today’s usage to be 10 Hours, 

26 minutes. 

 Press and hold for 3 seconds to reset the Energy Monitor’s 

counters. 

The display will blink, and counters will be cleared to zero. 

NOTE: 

Clearing the Energy Monitor counter will also clear the Filter Monitor 

counter , as Filter usage and Total Energy usage are the same. Also, 
clearing the filter Monitor counter will clear ALL Energy Monitor counters as 
well. 

Filter Monitor 

Your thermostat also keeps a record of the number of hours 
your filter has been in use. To maximize your system’s 
performance and energy efficiency, change or clear your 
filter regularly. 

 When the total system run time for heat and cool reaches 

400 hours, you need clean or change your system’s filter, “FILT” will continue 
to flash until the counter is set back to zero. 

The Filter Monitor will display up to 999 hours and 59 

minutes of usage. In this example, the counter is at 410 
Hours, 26 minutes. 

 To reset the Filter Monitor counter, depress ENER

 

for 3 

seconds. The display will blink, and the counter will be reset 
to zero. 

NOTE: 

Clearing the Filter Monitor counter will also clear ALL Energy Monitor 

counters, as Filter usage and Total Energy usage are the same. Also, 
clearing the Energy Monitor counters will clear the Filter Monitor counter as 
well.

 

Keyboard lock   

The keyboard can be locked to prevent unauthorized 
changes to the thermostat. 
To lock or unlock the keyboard, press and HOLD/RUN Key 
for 3 seconds. The keyboard is locked when LOCK appears 
on the display. 

 All keys are locked, Any time a key is pressed, LOCK will appear on the 

display for 1 second. 

Backlighting  

Your thermostat has an electroluminescent lamp that lights the display for 
easy viewing in the dark. 
When any key is pressed the display is illuminated. 
The display will remain illuminated for 8 seconds after the last key is pressed. 
This allows the light to stay on if you need to operate several keys. 

NOTE: 

If the thermostat is in Low Battery warning condition, the backlight 

will not operate. Replace with 2 new AAA alkaline batteries to restore the 
Backlight function. 

Low Battery Warning 

Your thermostat has a two-stage lower battery warning system. When the 
batteries are first detected to be weak, the first stage low battery warning is 
indicated by “BATT” flashing on the LCD display. At your 
earliest convenience, you need to replace the batteries with 
2 new AAA alkaline batteries. 
When the batteries become too weak for normal operation, 
the thermostat enters the second stage low battery warning 
which shuts down the thermostat. In this condition, “BATT” 
flashes alone on the display, and the thermostat will turn your 
system Off. Your system will remain shut-off until the 
batteries are replaced. 

NOTE: 

The thermostat will still keep the current Set Temperature and Filter 

run time in memory until new batteries are installed. After confirming that 
new batteries have been inserted, the thermostat will return to normal 
operation. 
 
 
 
 
 
 

Error Mode

 

If the thermostat is unable to control your system due to an 
unexpected battery problem, the thermostat will enter Error 
Mode. In this condition, the thermostat flashes 
“E1”,“E2”,”E3”or”E4”on the LCD display, and shuts off your 
system. To correct this problem, replace the batteries with 2 
new AAA alkaline batteries, even if you have recently replaced 
them. Move the battery out, and then hold any key to release 
the rest energy. Then place the battery again. You will need 
confirm normal operation. 
If Error Mode returns, please call us for further information. 

LCD display 

Information 

E1 Sensor 

Error 

E2 

System switch Error 

E3 No 

use 

E4 

E2 memory Error 

Warning Mode 

If the SYSTEM MONITOR SWITCH is close show the 
system have wrong.the thermostat flash “E5”on the LCD 
display. 

Auto Cut Off 

Your thermostat will automatically cutoff in Heat mode if the room 
temperature rises above 95

˚

F (35

˚

C). It will cut off in Cool mode if the room 

temperature drops below 40

˚

F (4

˚

C). Note that if your system has 

malfunctioned and no longer responds to thermostat controls, the Auto 
Cut-Off will have no effect.

 

TROUBLESHOOTING  

Problem

     

Solution

 

SCRAMBLED OR 
 DOUBLE 
DISPLAY 
(numbers over   
numbers) 

1. Remove clear mylar sticker.     

NO DISPLAY 

1.  Check battery connections and batteries 
2. Move the battery out

and then hold any key to 

release the rest energy. Then place the battery 
again. 

ENTIRE DISPLAY 
DIMS 

1. Replace Batteries 

AUTO/FAN DOES 
NOT TURN

 

ON  

1. Move Elec/Gas selector to opposite position is in

 

the correct position. 
2. There may be as much as 4 minute delay before 
the Heat or Cool system turns On-wait and check.   
(Compressor protection delay). 
3

Check your circuit breaks and switches to 

ensure there is power to the system. 
4. Replace batteries. 
5. Make sure your furnace blower door is closed 
properly. 
6. Check the position of the Furnace or Heat Pump 
selector switches: Normal/O/B. 

ERRATIC 
DISPLAY               

1. Move the battery out, and then hold any key to 
release the rest energy. Then place the battery 
again. 

IF UNIT 
CONTINUES 
TO OPERATE IN 
THE OFF 
POSITION      

1. Replace unit 
 

THERMOSTAT 
PERMANENTLY 
READS 
“E1”,”E2”,”E3”, 
“E4”. 

1. Replace unit. 
 

 

on

auto

fan

heat 

off

cool

system

TIME

TIME

TIME

TIME

TIME

ENER

ENER