Digital Thermostat Owners Manual 

Model:BLU2801 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES 

Structure of thermostat and explanation for the keypads 
 
 
 
 
 
We are pleased you have selected one of our broad line of wall thermostat. 
Our products are manufactured to high quality standards and are

 

designed 

for years of service.   

Read This Before Installing Thermostat 

OPERATION 

YOUR THERMOSTAT REPLACES 

Description BLU2801 

Heat Pump (No Aux. or Emergency Heat) 

Yes 

Heat Pump (with Aux. or Emergency Heat) 

Yes 

Standard Heat & Cooling Systems 

Yes 

Two Stage Heat & One Stage Cool 

Yes 

Standard Heat Only Systems 

Yes 

Millivolt Heat Only Systems– Floor or Wall 

Furnaces 

Yes 

Standard Central Air Conditioning 

Yes 

Gas or Oil Heat 

Yes 

Electric Furnace 

Yes 

Hydronic (Hot Water) Zone Heat-2 Wires 

Yes 

Hydronic (Hot Water) Zone Heat–3 Wires 

No 

This Thermostat will NOT control 110/220Volt systems. 

IMPORTANT 

2

,

 Read the entire installation section of this Owner’s Manual thoroughly 

before you begin to install or operate your Thermostat.

   

This thermostat can be used for conventional or heat pump 
system,  Please configure the thermostat according to 
Configuration Menu before operation. 

REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW. 

INSTALLATION 

3

All installation is normally performed at your thermostat. 

COMPRESSOR PROTECTION

 

4

The thermostat provides a 4 minutes delay after shutting of the heating or 

cooling system before it can be restarted. This feature will prevent damage 
to your compressor caused by rapid cycling. Note that this delay also applies 
to the heating system control. It does not provide a delay when there are 
power outages.you can select the function on or off at the configuration.

   

TEMPERATURE RANGE 

5,This thermostat can be programmed between 45

˚

F and 95

˚

F (7

˚

C and 

35

˚

C). However, it will display room temperatures from 30

˚

F to 99

˚

F (0

˚

C and 

37

˚

C). “HI” will be displayed if the temperature is higher than 99

˚

F (37

˚

C), 

and “LO” will be displayed if the temperature is lower than 30

˚

F (0

˚

C).This 

thermostat will automatically cutoff in Heat mode if the temperature rises 
above 95

˚

F (35

˚

C), and automatically cutoff in Cool mode if the temperature 

drops below 45

˚

F (7

˚

C). 

NOTE: if the thermostat measure a temperature over 99

˚

F(37

), ”HI” will be 

displayed on the LCD, if the temperature is below 32

˚

F(0

). and ”LO” will be 

displayed on the LCD. 

POWER FAILURE 

6

  Whenever the main power is interrupted or fails, the battery power 

retains and current time. This thermostat has permanent memory, although 
you will have to reset your clock when there are power outages. 

POWER SUPPLY 

7

The thermostat shall be powered by 24 VAC and with batteries as backup. 

BATTERY WARNING

 

8

Fresh alkaline batteries should provide about one year of service. 

However, when the batteries become drained, “BATT” will alternate on the 
display with the current time. When this message occurs, install 2 new AAA 
batteries, You have approximately 1 minute to change the batteries and keep 
thermostat’s clock. Once the batteries have become too low to ensure 
proper operation, your system will be turned off, and the display will be 
cleared except for “BATT” flashing on the LCD display. 

CAUTION: 

Once only the “BATT” only display occurs, the thermostat is shut 

down, and your system will no longer operate. In this condition, 
there is no temperature control of your dwelling.  

NOTE: The 

backlight will not function when the thermostat is in low battery condition. 

NOTE: If you plan to be away from the premises over 30 days, we 

recommend that you replace the old batteries with new alkaline 

batteries prior to leaving. 

INSTALLATION 

What You Need 
This thermostat includes two #8 slotted screws and two wall anchors for 
mounting. To install your thermostat, you should have the following tools and 
materials. 

 

 Slotted Screwdriver(s)         

 Small Philips screwdriver           

 Hammer 

 Electric drill and 3/16” bit   

 Two1.5V (AAA) size alkaline batteries 

(included) 

CAUTION: 

To prevent electrical shock and/or equipment damage, disconnect 

electric power to system at main fuse or circuit breaker box until 

installation is complete. 

Before removing wires from old thermostat's switching sub base, label each 
wire with the terminal designation it was removed from. 
1. Shut off electricity at the main fuse box until installation is complete. 
Ensure that electrical power is disconnected. 
2. Remove Old Thermostat: A standard heat/cool thermostat consists of 
three basic parts: 
a. The cover, which may be either a snap-on or hinge type. 
b. The base, which is removed by loosening all captive screws. 
c. The switching sub base, which is removed by unscrewing the mounting 
screws that hold it on the wall or adaptor plate.   
3. Remove the front cover of the old thermostat. With wires still attached, 
remove wall plate from the wall. If the old thermostat has a wall mounting 
plate, remove the thermostat and the wall mounting plate as an assembly. 
4. Identify each wire attached to the old thermostat. 
5. Disconnect the wires from the old thermostat one at a time. DO NOT LET 
WIRES FALL BACK INTO THE WALL. 
6. Install new thermostat using the following procedures. 

WARNING 

Do not use it on circuits exceeding specified voltage. Higher voltage 

will damage control and could cause shock or fire hazard. Do not short 

out terminals on gas valve or primary control to test. Short or incorrect 

wiring will damage thermostat and could cause personal injury and/or 

property damage.   

Selector Switches

 

Electric/Gas Switch (Fan Option) 

 

 

 

 

 

 

 

 

 

 

Figure 1. Electric/Gas Switch (Fan Option) 

This thermostat is configured from the factory to operate a heat/ cool, fossil 
fuel (gas, oil, etc.), forced air system. It is configured correctly for any system 
that DOES NOT require the thermostat to energize the fan on a call for heat. 
If you system is an electric heat or heat-pump system that requires the 
thermostat to turn on the fan on a call for heat, locate the ELEC/GAS switch 
on the back of the thermostat (see fig. 1) and switch it to the ELEC position. 
This will allow the thermostat to energize the fan immediately on a call for 
heat. If you are unsure if the heating/ cooling system requires the thermostat 
to control the fan, contact a qualified heating and air conditioning service 
person. When the thermostat is configured for Heat Pump, the thermostat 
will always power the circulatory fan on a call for heat in the HEAT mode. 
The ELEC/GAS switch must be set to match the type of Auxiliary heat your 
system uses for proper operation in the EMER mode. 
All wiring diagrams are for typical systems only. Refer to equipment 
manufacturers’ instructions for specific system wiring information. 

Attach Thermostat Base to Wall

 

1. Remove the packing material from the thermostat. Gently pull the cover 
straight off the base. Forcing or prying on the thermostat will cause damage 
to the unit. 
2. Connect wires beneath terminal screws on base using appropriate wiring 
schematic (see figs. 2 through 4). 
3. Place base over hole in wall and mark mounting hole locations on wall 
using base as a template. 
4. Move base out of the way. Drill mounting holes. 
5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. 
Place a level against bottom of base, adjust until level, and then tighten 
screws. (Leveling is for appearance only and will not affect thermostat 
operation.) If you are using existing mounting holes, or if holes drilled are too 
large and do not allow you to tighten base snugly, use plastic screw anchors 
to secure sub base. 
6. Push excess wire into wall and plug hole with a fireresistant material (such 
as fiberglass insulation) to prevent drafts from affecting thermostat operation. 
 
 
 
 
 
 
 
 
 
 

Figure 2. Thermostat base

 

 

 
 
 
 
 

Figure 3 Typical wiring diagram for single transformer heat pump 

systems 

 

 
 
 

 

 

Figure 4. Typical wiring diagram for two transformer heat pump 

systems with NO safety circuits 

 

 

 

 

 

 

Figure 5. Typical wiring diagram for two transformer heat pump 

systems with safety circuits in BOTH systems 

Heat Pump Terminal Outputs 

Refer to equipment manufacturers' instructions for specific system wiring 
information. You can configure the thermostat for use with the following heat 
pump system types: HEAT PUMP TYPE 1 1. Single stage compressor 
system; gas or electric backup. This thermostat is designed to operate a 
single-transformer system. If you have a two-transformer system, cut and 
tape off one transformer. If transformer safety circuits are in only one of the 
systems, remove the transformer of the system with NO safety circuits. If 
required, replace remaining transformer with a 75VA Class II transformer. 
After disconnecting one transformer, the two commons must be jumped 
together. 
Use the terminal output information below to help you wire the thermostat 
properly for your heat pump system. After wiring, see CONFIGURATION 
section for proper thermostat configuration. 

THERMOSTAT TERMINALS (HEAT PUMP) 

SYSTEM 

Heat Pump 1 

L Malfunction 

C* 24 

Volt(Common) 

24 Volt Emergency (hot) 

E/W1 

Emergency Mode 1st stage 

W2 

HP 1 and Emergency 2nd stage 

Y1 

Heat and Cool mode 1st stage 

(compressor) 

 

Blower/Fan Energized on call for Heat and 

Cool 

Set GAS/ELEC switch for Emergency 

mode 

Energized in Cool Mode 

Energized in Heat Emergency mode 

 
 
 
 
 
 

Figure 6. Typical wiring diagram for single transformer multi-stage 

systems 

CHECK THERMOSTAT OPERATION

 

Note: 

To prevent static discharge problems, touch side of thermostat to 

release static build-up before touching any keys. 

If at any time during testing your system does not operate properly, 

contact a qualified service person.

 

Fan Operation 

If your system does not have a G terminal connection, skip to Heating 
System System. 
1. Turn on power to system. 
2. Move FAN switch to ON position. The blower should begin to operate. 
3. Move FAN switch to AUTO position. The blower should stop immediately 

Heating System

 

1. Move system switch to heat mode. If the auxiliary heating system has a 
standing pilot, be sure to light it. 
2. Press to adjust thermostat setting to 1

 above room  temperature. The 

heating system should begin to operate. The display should show “STG1”. 
However, if the setpoint temperature display is flashing, the compressor 
lockout feature is operating (see Configuration menu, item 5). 
3. Adjust temperature setting to 3° above room temperature. If your system 
configuration is set at MS2or HP1, the auxiliary heat system should begin to 
operate and the display should show “STG1+2”. 
4. Press it to adjust the thermostat below room temperature. The heating 
system should stop operating. 

Emergency System

 

EMER by passing the Heat Pump to use the heat source wired to terminal E 
on the thermostat. EMER is typically used when compressor operation is not 
desired, or you prefer back-up heat only. 
1. Press SYSTEM switch to select Heat mode. then press EMER key.. 
“EMER” will show on the display. 
2. Press it to adjust thermostat setting above room temperature. The Aux. 
heating system will begin to operate. The display will show “STG1” “EMER” 
to indicate that the Aux. system is operating. 
3. Adjust temperature setting to 2°C above room temperature. The auxiliary 
heat system should begin to operate and the display should show “STG1+2”. 
4. Press to adjust the thermostat below room temperature. The Aux. heating 
system should stop operating. 

Cooling System

 

1. Move SYSTEM switch to select the Cool mode. 

Hot
120 VAC
Neutral

 

    

  

TRANSFORMER

(Class    Current 

Limited)

24 VAC

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Hot
120 VAC
Neutral

    TRANSFORMER
(Class 

 Current Lim

24 VAC

      

Limit or Safety
 Switches

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Limit or
 Safety
 Switches

Limit or
 Safety
 Switches

HOT

120 VAC

   Heat Pump Transformer
(Class     Current Limited)

24 VAC

Limit or Safety
 Switches

COMMON

HOT

120VAC

Auxiliary
 Heating 
Transformer
(Class 
Current Limited)

24VAC

Limit or
 Safety
 Switches

      NEUTRAL

      NEUTRAL

COMMON

     

The accessory relay scheme 
is required when safety
circuits ezist in both systems

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 

  Valve 

Energized in

 Heat, 

Emergency 

  Mode

Fan
Relay

Heat
Relay
Stage 1

Compressor
Contactor
Stage 1

Heat
Relay
Stage 2

    

Ⅱ 

GAS
  
  
EL
EC

Elec-Gas
Switch

M o u n t i n g
H o l e

M o u n t i n g
H o l e

Fan switch:     Fan switch for
Automatic or Continuous fan
operation

System switch:Selector switch
for cool,heat or off.

logo

LCD Display shows Time,Day,
Temperature,Program Number,
and other feature information
as required

Temperature Keys:Keys for raising
or lowering temperature setting

Soft touch programming
buttons(see below)

Front Door:
Covers keys
Open with
One finger
up and down

TIME

ENER

EMER

RUN

Measures and displays

heating and cooling system

operating time for Today,

Yesterday,This Week,Last

Week,or Total.By monitoring

your energy usage,you can

program the thermostat to
optimize energy savings.

For entering Time

Returns display to current time and temperature.

EMER Mode