ASB Series
Installation and Operating Instructions
Auto Silent Booster Pump
Din 1810 Form A No.40 68-75
hook wrench
Unscrew the “Locking Ring
(Part No.22-4)” to disassemble
the flow switch.
Discharge Side
Air Evacuation Plug (Part No. 21-2)
Suction Side
Priming Plug (Part No. 21-1)
Flow Switch Disassembly
Pump Trapped-Air Evacuation
21-1
22-4
22-0
22-3
22-2
22-1
21-2
3
The flow switch can be disassembled or replaced by using a “Din 1810 Form A
No.40 68-75 hook wrench” or other similar pipe wrench to unscrew the “Locking
Ring (Part No. 22-4)”
The filling of suction piping and pump chamber must be very carefully to ensure
no any air inside. Trapped-air will cause pump low discharge / pressure, and
resulting abnormal operation. Trapped-Air evacuation can be accomplished by
opening all discharge valves, or unscrewing the discharge side “Priming Plug
(Part No. 21-2)” during pump operation.
PROBLEM – Pumps fail to start when the discharge devices are opened.
Test
Schematic
Status
Voltage
is normal
Go to test “A-2".
A-1
Input
Voltage
Check
No power
Check the controller power source and circuit breaker.
Voltage
is normal
1: Turn the power off, and check if the motor rotate manually.
2: If the motor or pump casing is overheating, the motor
winding or pump casing thermostat might be tripped due to
motor overloading or pump dry running. The motor will
start running automatically, when the motor winding or
pump casing temperature back to normal.
A-2
Output
Voltage
Check
No power
Go to test “A-3”.
Motor still
fails to start
Replace the controller.
A-3
Short
“P”
Socket
Motor starts
running
1: Make sure the discharge device is fully opened, or
discharge piping is blocked.
2: Lower the pressure switch setting.
3: Replace the pressure switch.
PROBLEM – Pumps fail to stop after all the discharge appliances are closed.
Test
Schematic
Status
Motor stops
Go to test “B-2” and “B-3”.
B-1
Remove
“P” & “Q”
Plugs
Motor still
running
Replace the controller.
Motor Stops The flow switch function is normal.
B-2
Remove
“P”
Plug
Motor still
running
1: Make sure if the flow switch is activated due to the leakage
of discharge piping or devices.
2: Clean the inlet check valve to ensure the flow switch can
back to normal position.
3: Replace the flow switch.
Motor Stops The pressure switch function is normal.
B-3
Remove
“Q”
Plug
Motor still
running
1: Make sure the inlet water source is enough.
2: Check the suction piping for air-locked or leakage which
result low pump output pressure.
3: Lower the pressure switch setting.
4: Replace the pressure switch.
PROBLEM – Pumps cycle frequency or unstable under “Power ON”
Test
Schematic
Status
Motor back
to normal
1: Avoid small discharge piping leakage or operation which
will cause unstable flow switch ON/OFF switching.
2: Recharge pressure tank air up to 1~1.2 kg/cm
2
.
3: Replace the flow switch.
C-1
Short
“Q”
Socket
Motor still
unstable
Replace the controller.
CAUTION
PLEASE DO NOT ADJUST PRESSURE SWITCH SETTING UNLESS
Troubleshooting
Causes / Solutions
Causes / Solutions
Causes / Solutions
ALL THE TROUBLESHOOTING PROCESS HAS BEEN DONE.
R
Comfort Home
Limited Warranty:
Products of Comfort Home are warranted to the first user only to be free
of defects in material and workmanship for a period of 12 months from date
of installation, but no more than 24 months from date of manufacture.
Comfort Home's liability under this warranty shall be limited to repairing or
replacing at our election, without charge, FOB Comfort Home's distribution
center or authorized service agent. Comfort Home will not be liable for
any cost of removal, installation, transportation or any other charges that
may arise in connection with warranty claim.
The warranty period commences on the date of original purchase of the
equipment. Proof of purchase and installation date, failure date, and
supporting installation data must be provided when claiming repairs under
warranty.
This warranty is subject to due compliance by the original purchaser with
all directions and conditions set out in the installation and operating
instructions. Failure to comply with these instructions, damage or breakdown
caused by fair wear and tear, negligence, misuse, incorrect installation,
inappropriate chemicals or additives in the water, inadequate protection
against freezing, rain or other adverse weather conditions, corrosive or
abrasive water, lightning or high voltage spikes or through unauthorized
persons attempting repairs are not covered under warranty.
Comfort Home will not be liable for any incidental or consequential damages,
losses, or expenses, arising from installation, use, or any
other causes.
There are no express or implied warranties, including merchantability
or fitness for a particular purpose, which extend beyond those
warranties described or referred to above.
Certain countries do not permit the exclusion or limitation of incidental
or consequential damages or the placing of limitations on the duration
of an implied warranty, therefore, the limitations or exclusions herein
may not apply. This warranty sets forth specific legal rights and
obligations, however, additional rights may exist, which may vary from
countries to countries.