REPLACEMENT PARTS LIST

For replacement parts, call our customer service department at 1-814-643-1775

,

 

8:30 a.m. –  4:30

 

p.m., 

CST, Monday – Friday

.

 WARNING

: Only use genuine replacement parts from the World Marketing of America, Inc. Using 

     any parts other than the original replacement parts may result in property damage, personal injury 

     or even death.

11

1

8

2

13

5

12

6

3-1

3-2

3

7

14

18

19

4

9

10

Item 

No.

Description

Qty

Part Number

KWD216

KWD326

KWDB322

KWD526

KWDB542

1

Front Panel Assembly

1

AQ000258

AQ000257

AQ000256

2

Burner Assembly

1

AQ000137

AQ000065

AQ000022

3

ODS Assembly (Complete)

3-1

ODS -(NG) Natural Gas Pilot

1

IR30K-22(NG)

IR30K-22(NG)

IR30K-22(NG)

3-2

ODS - (LP) Propane Gas Pilot

1

IR30K-22(LP)

IR30K-22(LP)

IR30K-22(LP)

4

ODS Connector Harness

1

IR30K-22-01(L=700) IR30K-22-01(L=700)

IR30K-22-01(L=700)

5

Thermostatic Gas Valve, SIT 630

1

0630560

0630560

0630560

6

Manual Gas Valve

1

N/A

N/A

N/A

7

Gas Selector Valve

1

GH01

GH01

GH01

8

Regulator Bracket

1

AQ000015

AQ000015

AQ000015

9

Regulator, (LP) Propane 10" WC

1

GR-130A(12K)

GR-130A(18K)

GR-130A(30K)

10

Regulator, (NG) Natural Gas 5" WC

1

GR-130(12K)

GR-130(18K)

GR-130(30K)

11

Front Grille

1

AQ000264

AQ000263

AQ000250

12

Wall Mounting Bracket

1

AQ000108

AQ000006

AQ000006

13

Piezo

1

AQ000247

AQ000247

AQ000247

14

Knob, Selector Valve

1

AQ000251

AQ000251

AQ000251

15

Support Legs (Select Models)

2

AQ000351*

AQ000351*

AQ000351*

16

Fan Assembly (Select Models)

1

AQ000232*

AQ000232*

AQ000232*

17

Hardware Pack

1

AQ000367*

AQ000367*

AQ000367*

18

Nozzle - LP

1

IR12K-LP

IR18K-LP

IR30K-LP

19

Nozzle - NG

1

IR12K-NG

IR18K-NG

IR30K-NG

* Item/version not shown in exploded parts diagram

Содержание KWD216

Страница 1: ...n and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 8 of this manual This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with propane or natural gas This appliance is equipped with a simple means to switch between propane and natural gas Field...

Страница 2: ......

Страница 3: ...Gas Propane Ignition Manifold Pressure 5 in W C 10 in W C Inlet Gas Pressure Maximum 14 in W C 14 in W C Minimum For purposes of input adjustment 6 in W C 11 in W C Dimensions in H x W x D Fan Ratings Select Models Piezo Ignitor KWD526 KWDB542 120V 60Hz 18W 0 15A 20 5 in x 28 in x 10 25 in SERIES MAX BTU 12 000 12 000 18 000 18 000 Fuel Type Natural Gas Propane Natural Gas Propane Ignition Manifol...

Страница 4: ...objects on the heater WARNING Due to high temperatures locate this appliance out of traffic and away from furniture and draperies This appliance is intended for supplemental heating This appliance can be used with propane or natural gas It is shipped from the factory adjusted for use with propane CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning resemble the flu with headaches diz...

Страница 5: ...s turn heater and pilot off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 8 Do not use heater if any part has been under water Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water 9 Turn off and unplug he...

Страница 6: ...med air into the space more rapidly NOTE This is an optional accessory and is not required for operation of the heater State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In th...

Страница 7: ...oduces approximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 Kw of gas input per hour An unvented room heater is intended as a supplemental heater rather than a primary heat source In most supplemental heat applications the water vapor does not create a problem In most applications the water vapor enhances the low humidity atmosphere experienced during cold weather The following steps wi...

Страница 8: ...e unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining rooms are connecting only if there are doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combusti...

Страница 9: ...BTU hr Example Gas heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum BTU hr the space can support with the actual amount of BTU hr used _______ BTU h...

Страница 10: ...ational Fuel Gas Code NFPA 54 ANS Z223 1 Air for Combustion and Ventilation for required size of ventilation grills or ducts Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or duct You must provide two permanent openings one within 12 in of the ceiling and one within 12 in of the floor Connect these items directly to the outdoors or spaces open to the outdoors The...

Страница 11: ...upport legs Select models WARNING Maintain the minimum clearances shown in See Fig 2 If you can provide greater clearances from floor ceiling and joining wall Fig 2 Mounting clearances as viewed from front of heater inches LEFT RIGHT TOP BOTTOM FRONT REAR 8 in 36 in 3 in 36 in 0 in to spacer Bottom clearance is from bottom of heater to surface of carpet tile or other combustible material Minimum C...

Страница 12: ...heater between the locked positions 3 Remove plug from the inlet of the NG regulator 4 If the LP plug was removed previously apply thread sealant to ensure that there are no leaks and install the NG plug into the inlet of the LP regulator and tighten firmly See Fig 5 5 Replace selector valve access panel NG TO LP CONVERSION 1 Before gas conversion remove screws and access panel for selector valve ...

Страница 13: ... corner See Fig 10 3 This fan is equipped with manual MAN and automatic AUTO settings See Fig 11 on page 13 Set the rocker switch to MAN for manual mode allowing the fan to continuously run until the rocker switch is returned to the OFF O position Set the rocker switch to AUTO for the automatic mode which will turn the fan on and off based on ambient room temperature It may take 5 to 10 minutes fo...

Страница 14: ... Screws M4 15 1 Set down a blanket onto the table where the heater will be placed for leg installation to prevent scratch ing of the table and or the heater 2 Set back of heater on table with the bottom of heater extending outside the table edge 3 Fasten Support Legs to heater using Support Leg Screws Fig 13 Note If the heater is to be installed directly on carpet ing tile or other combustible mat...

Страница 15: ...ape mounting bracket to wall where heater will be located Make sure mounting bracket is level 2 Mark screw locations on wall See Fig 16 Note Mark only last hole on each end of mounting bracket Insert 2 wood screws ST 8 45 16 total through these holes only 3 Remove tape and mounting bracket from wall Attaching Mounting Bracket To Wall Note Expansion bracket wood screws ST 8 45 16 and wall hanging s...

Страница 16: ...ith expansion bracket 6 Insert expansion bracket screws ST4 8 15 16 through wall mounting bracket and into expansion brackets 7 Tighten expansion bracket screws ST4 8 15 16 until mounting bracket is firmly fastened to wall 8 Check that the bracket is secure before mounting heater Attaching Wall Hanging Spacers to Heater WARNING Failure to properly install the wall hanging spacers may result in pro...

Страница 17: ...must be a minimum 6 WC for NG 11 WC for LP with a max pressure of 14 WC for NG 14 WC for LP If gas line pressure is higher regulator damage could occur CAUTION Never connect heater directly to an LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when con...

Страница 18: ...G 3 5kPa The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa Pressure Testing Gas Supply Equal To or less than 1 2 PSIG 3 5kPa The appliance must be isolated from the gas supply piping system by closing its equipment shut off valve during any pressure testing of t...

Страница 19: ...chnician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS MANUAL GAS CONTROL 1 STOP Read the safety information above on this page 2 Turn off all electric power to the appliance 3 Push in gas control knob slightly and turn clockwise to OFF position See Fig 22a NOTE Knob cannot be turned from PILOT to OFF unl...

Страница 20: ...depressed for 30 seconds after pilot lights Release control knob Note If pilot goes out repeat steps 3 through 7 Wait 1 min ute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call your service technician or gas supplier If the control knob does not pop up when released stop and immediately and call ...

Страница 21: ... between HIGH 5 and LOW 1 See Fig 25 MANUAL CONTROL OPERATION Manual valves remain burning in the HIGH setting until manually turned to OFF See Fig 25 Fig 25 Control Knob Position Manual Thermostatic OPERATION 1 2 3 4 5 O F F P I L O T TO TURN OFF GAS TO APPLIANCE 1 Turn off all electric power to the appliance if service is to be performed 2 Push in gas control knob slightly and turn clockwise to ...

Страница 22: ... 28 shows a correct burner flame pattern Fig 29 shows an incorrect burner flame pattern with lifting and excessive flame height If burner flame is incorrect turn heater off see To Turn Off Gas to Appliance page 20 see Troubleshooting pages 23 through 26 WARNING If yellow tipping occurs your heater could produce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow...

Страница 23: ...nd using compressed air no greater than 30 PSI You can use a vacuum cleaner in the blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly CAUTION Never use a wire needle or similar object to clean ODS pilot This can damage ODS pilot unit 1 Shut off the unit including the pilot Allow the un...

Страница 24: ...ctrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad ignitor module or ignition module 1 Replace ODS 2 Replace ODS 3 Replace ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace ignitor module or ignition module Unit shuts off after running a few minutes 1 Gas supply is turn...

Страница 25: ...ition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 22 or contact customer service Burner backfiring during combustion 1 Burner orifice is clogged or damaged 2 Burner is damaged 3 Gas regulator is damaged 1 Clean burner orifice see Care and Maintenance page 22 or contact customer service 2 Contact dea...

Страница 26: ...er 3 Clean ODS pilot see Care and Maintenance page 22 Gas odor exists even when control knob is in OFF posi tion 1 Gas leak See Warning Statement at top of page 22 2 Control valve is defective 1 Locate and correct all leaks see Checking Gas Connections page 17 2 Contact customer service Moisture conden sation noticed on windows 1 Not enough combustion ventilation air 1 Refer to Air for Combustion ...

Страница 27: ...LE CAUSE PROBLEM QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories and repair and servicing of equipment The term qualified agency means any individual firm corporation or company that either in person or through a representative is engaged in and is responsible for a Installing testing or replacin...

Страница 28: ...K 22 LP IR30K 22 LP 4 ODS Connector Harness 1 IR30K 22 01 L 700 IR30K 22 01 L 700 IR30K 22 01 L 700 5 Thermostatic Gas Valve SIT 630 1 0630560 0630560 0630560 6 Manual Gas Valve 1 N A N A N A 7 Gas Selector Valve 1 GH01 GH01 GH01 8 Regulator Bracket 1 AQ000015 AQ000015 AQ000015 9 Regulator LP Propane 10 WC 1 GR 130A 12K GR 130A 18K GR 130A 30K 10 Regulator NG Natural Gas 5 WC 1 GR 130 12K GR 130 1...

Страница 29: ...ANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL WORLD MARKETING OF AMERICA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow lim...

Страница 30: ...ably due for a good cleaning Replacement of the thermocouple or pilot assembly is generally not needed Review Heater Maintenance in the owners manual While we want everyone to be completely satisfied with their purchase it is impossible to warranty problems occurring from improper use or installation or a lack of maintenance Warranty Registration Appliance Model _______________________ Serial ____...

Отзывы: