OFF
ON
Extension Cord
Use extension cord if needed. The cord must have a
three-prong, grounding plug and a three-hole receptacle.
Make sure cord is in good shape. It must be heavy
enough to carry the current needed. An undersized cord
will cause a drop in line voltage. This will result in loss
of power and overheating. Use a No. 16 AWG cord for
lengths less than 50 feet.
104079-01
REV. B
8/97
Red
Red
Fan Switch
(Auto/Off/On)
Blue
Blue
Thermostat
Switch
(N.O.)
Green
White
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
3
Auto
Figure 7 - Wiring Diagram For Fan Accessory Standard Installation
Operating Fan
This blower has three settings: ON, OFF, and AUTO.
In the ON position, the blower will operate con-
stantly. In the OFF position, the blower will not
operate. In the AUTO position, the blower will start
when the thermostat senses a sufficient increase in
firebox temperature.
Note:
Your fireplace and thermostat blower will not
turn on and off at the same time. The fireplace may
run for several minutes before the blower turns on.
After the heater modulates to the pilot position, the
blower will continue to run. The blower will shut off
after the firebox temperature decreases.
Note:
It is safe to operate fireplace with blower
turned off. However, the blower helps distribute
heated air from the fireplace.
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
Technical Service Department 1-800-323-5190
Parts Department 1-800-972-7879
Figure 8 - Auto/Off/On Switch
Auto/Off/On Switch