LIGHTING 

INSTRUCTIONS

 WARNING

•  If  fireplace  has  glass  doors, 

never operate this heater with 

glass doors closed. If you op

-

erate heater with doors closed, 

heat  buildup  inside  fireplace 

will cause glass to burst. Also 

if fireplace opening has vents 

at the bottom, you must open 

the  vents  before  operating 

heater.

•  You must operate this heater 

with  a  fireplace  screen  in 

place.  Make  sure  fireplace 

screen  is  closed  before  run

-

ning heater.

NOTICE: During initial operation 

of new heater, burning logs will 

give off a paper-burning smell. 

Orange flame will also be pres

-

ent. Open damper or window to 

vent smell. This will only last a 

few hours.

Note:

 Home owners generally prefer to op-

erate their heater with the chimney damper 

closed. This will put all the heat into the room. 

However, there may be times you will desire 

the full flames of the HI heat setting but will 

find the heat output excessive. You can open 

the chimney damper (if you have one) fully or 

partially to release some of the heat.

  WARNING:  Damper  handle 

will  be  hot  if  heater  has  been 

running.

1.  STOP!  Read  the  safety  information, 

page 15.

2.  Make sure equipment shutoff valve is fully 

open.

3.  Set switch in the OFF position.

4.  Press in and turn control knob clockwise 

 to the OFF position (see Figure 18).

  WARNING:  Burners  will 

come  on  automatically  within 

one  minute  when  the  switch 

is  in  the  ON  position  after  the 

pilot is lit.

5.  Wait five (5) minutes to clear out any gas. 

Then smell for gas, including near the floor. 

If you smell gas, STOP! Follow “B” in the 

safety information on page 15. If you don’t 

smell gas, go to the next step.

6.  Press in and turn control knob counter-

clockwise 

 to the PILOT position. 

Press in control knob for five (5) seconds 

(see Figure 18).

 

Note:

 You may be running this heater for 

the first time after hooking up to gas sup

-

ply. If so, the control knob may need to be 

pressed in for 30 seconds or more. This will 

allow air to bleed from the gas system.

7.  With control knob pressed in, press and 

release ignitor button. This will light pilot. 

The pilot is attached to the front burner. If 

needed, keep pressing ignitor button until 

pilot lights.

 

Note:

 If pilot does not stay lit, contact a 

qualified service person or gas supplier for 

repairs. Until repairs are made, light pilot 

with match. To light pilot with match, see 

Manual Lighting Procedure

, page 18.

8.  Keep control knob pressed in for 30 seconds 

after lighting pilot. After 30 seconds, release 

control knob.

• If control knob does not pop out when 

released, contact a qualified service person 

or gas supplier for repairs.

 

Note:

 If pilot goes out, repeat steps 4 

through 8.

9.  Slightly push in and turn control knob coun-

terclockwise 

 to the ON position.

Figure 18 - Control Knob and Ignitor 

Button Location, Manual Controlled

Piezo Ignitor

Switch 

Control Knob

Flame Adjustment Knob

OPERATING HEATER

Continued

Содержание CSM2618NR

Страница 1: ...al switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departmen...

Страница 2: ...ce with ANSIZ21 11 2 Exception Donot install this appliance in a fac tory builtfireplacethatincludes instructions stating it has not been tested or should not be used with unvented gas logs WARNING Th...

Страница 3: ...ns toblowdirectlyintothefireplace Avoidanydraftsthatalterburner flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting WARNING Do not...

Страница 4: ...these products may create a white powder residue within the burner box or on adjacent walls and furniture 9 This heater needs fresh outside air ventilation to run properly this heater has an Oxygen De...

Страница 5: ...in the Commonwealth of Massachusetts Product Features OPERATION This heater is clean burning It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both r...

Страница 6: ...l Gas Code ANSI Z223 1 NFPA 54 defines a confined space as a space whose vol ume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances install...

Страница 7: ...hodsdescribed in the National Fuel Gas Code ANSIZ223 1 NFPA54Section5 3 or applicable local codes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining un co...

Страница 8: ...NING Seal any fresh air vents or ash clean out doors located on floor or wall of fire place If not drafting may cause pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damp...

Страница 9: ...IREPLACE CLEARANCE TO COMBUSTIBLE MATERIALS SIDE WALL 16 CEILING 42 FLOOR 5 LOG SIZING REQUIREMENTS MINIMUM FIREBOX SIZE LOG SIZE HEIGHT DEPTH FRONT WIDTH REAR WIDTH 18 18 14 30 20 5 24 18 14 35 24 5...

Страница 10: ...Figure 6 are not met you must have a hood When using a hood there are still certain minimum mantel clearances required Follow minimum clearances shown in Figure 7 when using hood Figure 6 Minimum Mant...

Страница 11: ...ON Note When used as a vented decorative appliance must be installed only in a solid fuel burning fireplace with a working flue and constructed of noncombustible material For Massachusetts Residents O...

Страница 12: ...s needed You must raise the fireplace floor to allow access to heater control panel This will insure adequate air flow and guard against sooting Raise fireplacefloorwithnoncombus tiblematerial Makesur...

Страница 13: ...Tank External Regulator Figure 13 External Regulator With Vent Pointing Down Vent Pointing Down For propane LP units the installer must supply an external regulator The external regulator will reduce...

Страница 14: ...pply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reco...

Страница 15: ...ints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater page 16 Check all other internal joints for leaks 7 Turn off heater Equipment Shutoff Valve Open Closed...

Страница 16: ...lly within one minute when the switch is in the ON position after the pilot is lit 5 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B...

Страница 17: ...Figure 15 page 15 MANUAL LIGHTING PROCEDURE 1 Follow steps 1 through 6 under Lighting Instructions page 16 2 Depress control knob and light pilot with match 3 Keep control knob pressed in for30 second...

Страница 18: ...ime or as a child safety feature to prevent accidental ignition of the fireplace the receiver ON OFF REMOTE switch should be in the OFF position Auto Shutoff Feature 1 If the average room temperature...

Страница 19: ...yellow color yellow decorative flames are visible as the flames exit the log set The base of the log set and the underside of the top logs glow red Natural gas models will burn with more blue flame wh...

Страница 20: ...can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least t...

Страница 21: ...pe Propane LP Only Ignition Piezo Manifold Pressure 10 6 3 W C Inlet Gas Pressure in of water Maximum 14 W C Minimum 11 W C For purpose of input adjustment Manufactured by DESA 1769 E Lawrence St Russ...

Страница 22: ...ne LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tightennuthold...

Страница 23: ...rol knob pressed in 30 seconds 3 Wait one minute for safety in terlock system to reset Repeat ignition operation 4 Fully open equipment shutoff valve 5 A Contact local natural or propane LP gas compan...

Страница 24: ...2 Operate burners until air is removed from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum instal lation clearances see pages 9 through 12 4 Clean burners see...

Страница 25: ...logged 1 Gas leak See warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between con trol valve and burner 2 Gas leak See warning statement at top of page 1 Han...

Страница 26: ...eater the replacement part number EQUIPMENT SHUTOFF VALVE GA5010 For all models Equipment shutoff valve with 1 8 NPT tap Fits 1 2 NPT pipe FIREPLACE HOOD Black GA6050 Brass GA6052 Antique Brass GA6053...

Страница 27: ...r log pieces Control Cover Media Kit cc100 For all models This kit is used as an addition to or instead of the Floor Media Kit FM100 It includes 6 fiber log chunks to be placed on the fireplace floor...

Страница 28: ...www desatech com 120163 01A 28 Illustrated Parts Breakdown Models CSM2618NR CSM2618PR CSM3624NR and CSM3624PR 1 4 5 3a 3b 6 9 11 2 12 13 16 18 8 19 22 7 10 20 17 14 15...

Страница 29: ...pter 1 9 111804 01 Burner 1 111804 03 Burner 1 10 111819 04 Orifice 1 111819 05 Orifice 1 111819 14 Orifice 1 111819 15 Orifice 1 11 111807 01 Valve 1 111807 02 Valve 1 12 111796 01 Valve Bracket 1 13...

Страница 30: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 31: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 32: ...odes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result...

Отзывы: