Comfort Glow CHDV32NR Скачать руководство пользователя страница 1

For more information, visit www.fmiproducts.com

DIRECT-VENT FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

NATURAL GAS

CHDV32NR

 WARNING: If the information in this manual is not 

followed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
—  Do  not  store  or  use  gasoline  or  other   flammable 

vapors and liquids in the  vicinity of this or any other 

appliance.

—  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

—  Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

INSTALLER: Leave this manual with the appliance
CONSUMER: Retain this manual for future reference.

PFS

®

US

Содержание CHDV32NR

Страница 1: ...uids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelyca...

Страница 2: ...ce must be performed by a qualified installer service agency or the gas supplier WARNING This product contains and or generates chemicals known to the State of California to cause cancer or birthdefec...

Страница 3: ...an be dangerous Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace WARNING This appliance is only for use with the type of...

Страница 4: ...ational Electrical Code ANSI NFPA 70 9 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 10 Do not...

Страница 5: ...gh temperatures do not locate this fireplace in high traffic areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your fireplace is to be installed direct...

Страница 6: ...terials 0 clear ance to combustible materials are for framing purpose only NOTICE This fireplace is in tended for use as supplemental heat Use this fireplace along with your primary heating sys tem Do...

Страница 7: ...0 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canad...

Страница 8: ...pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning ap...

Страница 9: ...ht into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Hori...

Страница 10: ...ews provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Combustible Exterior Wall Only Slide wall firestop over vent pipe before con necting horizontal run to vent...

Страница 11: ...ion cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly...

Страница 12: ...1 2 min None 30 max 51 1 2 min 1 ft 48 max 63 1 2 min 2 ft 60 max 75 1 2 min 3 ft 84 max 87 1 2 min 4 ft 20 max Ground Floor Corner Venting Not to Exceed H Limits SNORKEL TERMINATION INSTALLATION Rec...

Страница 13: ...iguration for Venting Using Two 90 Elbows 45 Elbow HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sys tem...

Страница 14: ...ould be framed to 10 x 10 inside dimensions as shown in Figure 9 on page 9 using framing lumber the same size as the ceiling joists If the area above the ceiling is an insulated ceiling or attic space...

Страница 15: ...H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizontal Runs Vertical Round High Wind Termination Shown Note In...

Страница 16: ...wn 45 Elbow High Altitude Installation Your FMI PRODUCTS LLC direct vent fire place has been tested and approved for eleva tions from 0 2 000 feet USA and elevations from 0 4 500 feet Canada When inst...

Страница 17: ...ipe Wall Firestop Storm Collar Roof Flashing 0 12 6 12 26 Screws VKC 47 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws...

Страница 18: ...The blower will fit inside backopeningandbeheldinpositionagainst back wall by magnets see Figure 25 4 Be certain that all wire terminals are securely attached to terminals on blower motor and screw r...

Страница 19: ...o sense temperature and properly operate Blower will be held in position against back wall by magnets incorporated onto blower housing see Figure 28 4 Be certain that all wire terminals are securely a...

Страница 20: ...have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint...

Страница 21: ...ine as shown in Figure 31 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped ma...

Страница 22: ...ce or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 3 Check all joints from propane LP supply tank or gas meter to equipment shutoff valve see F...

Страница 23: ...als are in positions on unit as pictured in Figure 36 If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient...

Страница 24: ...ire assembly glass and frame must be replaced If glass is broken wear gloves and tape the remaining fragments onto the frame 1 Remove screen assembly by pushing the rod either left or right and then d...

Страница 25: ...el 7 Install the right brick panel using the same method described 8 Replace deflector shield using screws removed in step 4 9 Install logs lava rock and ember material see Installing Logs Lava Rock a...

Страница 26: ...and grate prongs see Figure 49 This will create glowing ember appear ance as flame touches ember material Do not block air slots by using too much ember material in one area It is not necessary to us...

Страница 27: ...igure 50 5 Slide other end of adjusting plate shim in slot on mitered edge of side trim see Figure 50 Side Trim Mitered Edge Shim Adjusting Plate Set Screws Top Trim Slot Slot Figure 50 Assembling Tri...

Страница 28: ...pped with an igni tion device which automatically lights the pilot Do not try to light by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because...

Страница 29: ...ssory Gas Control Knob in ON Position Variable Control Knob Figure 54 On Off Hand Held Remote Control Unit HRC100 Control Button Indicator Light IMPORTANT Do not leave the selector switch in the REMOT...

Страница 30: ...et wall thermostat to desired temperature This thermostat has been electronically cali brated at the factory and requires no adjust ment or leveling Upon installation the thermostat must be al lowed t...

Страница 31: ...Figure 57 Typical Flame Pattern Thermocouple Thermopile 1 8 Pilot Burner Piezo Ignitor Figure 56 Pilot Assembly 3 8 to 1 2 Cleaning and Maintenance WARNING Turn off fireplace and let cool before clea...

Страница 32: ...to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint Cleaning and Maintenance Continued logs If you remove logs for cleaning refer to Insta...

Страница 33: ...uipment shutoff valve closed 2 Gas control knob not in PILOT position 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP mod...

Страница 34: ...d pressure is too low 2 Burner porting or orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective 1 Residues from manufac turing processes and logs curing REM...

Страница 35: ...installa tion REMEDY 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP or natural gas compan...

Страница 36: ...above 2 Control valve defective 1 Gas leak See Warning statement above 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 4 Improper venting or exces sive blocka...

Страница 37: ...and serial numbers of your heater ready You can also visit our web site at www fmiproducts com Specifications CHDV32NR Rating 12 000 18 000 Btu Hr Gas Type Natural Ignition Piezo Manifold Pressure 3 5...

Страница 38: ...nted on off switch gwms2 Allows burner system to be turned on and off with a wall switch Accessories Continued Thermostatically controlled blower kit BKT Provides better heat distribution Blower turns...

Страница 39: ...www fmiproducts com 111986 01G 39 Parts Model CHDV32NR 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9 11 17 15 4 5 16 3...

Страница 40: ...108897 01 Rear Refractory Brick Panel Not Included 1 12 109082 03 Heat Shield 1 13 108901 01 Right Refractory Brick Panel Not Included 1 14 108901 02 Left Refractory Brick Panel Not Included 1 15 1141...

Страница 41: ...www fmiproducts com 111986 01G 41 Parts BURNER ASSEMBLY Model CHDV32NR 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 11 17 19...

Страница 42: ...m 1 5 14389 Millivolt Valve Natural Gas 1 6 14492 Piezo Ignitor 1 7 14500 Brass Fitting 2 8 14253 Flexible Connector 1 9 14511 Ignitor Bracket 1 10 14528 Brass Elbow Fitting 1 11 104506 25 Orifice Nat...

Страница 43: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____...

Страница 44: ...product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic mat...