SAFETy

 WARNING: Improper instal

-

lation,  adjustment,  alteration, 

service  or  maintenance  can 

cause injury or property damage. 

Refer to this manual for correct 

installation  and  operational 

procedures.  For  assistance  or 

additional  information  consult 

a  qualified  installer,  service 

agency or the gas supplier.

 WARNING: This is a gas-fired 

appliance.  It  uses  air  (oxygen) 

from the room in which it is in

-

stalled. Provisions for adequate 

combustion  and  ventilation  air 

must  be  provided.  Refer  to  the 

National  Fuel  Gas  Codes, ANSI 

Z233.1/NFPA 54, Air for Combus-

tion and Ventilation

.

  WARNING:  This  appliance 

is  for  installation  only  in  a 

solid-fuel  burning  masonry  or 

UL127  factory-built  fireplace, 

constructed of noncombustible 

material,  and  connected  to  a 

working  flue.  (See  page  6  for 

minimum flue opening.)

This appliance may be installed 

in an aftermarket*, permanently 

located, manufactured (mobile) 

home, where not prohibited by 

state or local codes.

*Aftermarket:  Completion  of  sale,  not  for  pur

-

pose of resale, from the manufacturer.

State  of  Massachusetts:  The 

installation  must  be  made  by 

a  licensed  plumber  or  gas 

fitter  in  the  Commonwealth  of 

Massachusetts.

 WARNING: This product con-

tains and/or generates chemicals 

known to the State of California 

to cause cancer or birth defects 

or other reproductive harm.

 WARNING: Keep flue open 

when operating unit.

IMPORTANT:  Read  this  owner’s 

manual carefully and completely 

before trying to assemble, operate 

or service this log set. Improper use 

of this log set can cause serious 

injury  or  death  from  burns,  fire, 

explosion,  electrical  shock  and 

carbon monoxide poisoning.

 DANGER: Carbon monoxide 

poisoning may lead to death!

Carbon  Monoxide  Poisoning:

  Early  signs  of 

carbon  monoxide  poisoning  resemble  the 

flu,  with  headaches,  dizziness  or  nausea.  If 
you  have  these  signs,  the  log  set  may  not 
be working properly. 

Get fresh air at once!

 

Have  log  set  serviced.  Some  people  are 

more affected by carbon monoxide than oth-

ers. These include pregnant women, people 
with  heart  or  lung  disease  or  anemia,  those 
under  the  influence  of  alcohol  and  those  at 
high altitudes.

TABLE OF CONTENTS

Safety ..................................................................

2

Local Codes

.........................................................

4

Unpacking............................................................

4

Product Identification ...........................................

5

Optional Product Features...................................

5

Installation ...........................................................

5

Operation

 ...........................................................

14

Cleaning and Maintenance

 ................................

15

Troubleshooting .................................................

16

Service Hints .....................................................

19

Technical Service...............................................

19

Replacement Parts

 ............................................

19

Parts

 ..................................................................

20

Accessories

 .......................................................

26

Warranty

 ..............................................Back Cover

Содержание and CVDR30

Страница 1: ...as supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Ret...

Страница 2: ...made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgenerateschemicals known to the State of California to cause cancer or birth defects or...

Страница 3: ...ng fire place the chimney flue and firebox must be cleaned of soot creosote ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimneyfluefordamage Ifda...

Страница 4: ...ontrol system if using GA9050A 1 or GA9150A and any gas control which has been under water 10 To help prevent breakage new logs must be broken in see Curing Logs page 14 11 Turn log set off and let co...

Страница 5: ...urces to light This system may be connected to a wall switch or hand held wireless remote control See Accessories page 26 Remote Control Accessories There is an optional hand held ON OFF re mote contr...

Страница 6: ...6 27 18 18 Model BFLT18 Front Width Back Width Depth Height 28 16 15 1 2 18 Model BFLT24 Front Width Back Width Depth Height 30 22 15 1 2 18 installation Continued NOTICE Installation service andrepai...

Страница 7: ...st be installed or the damper blade must be cut or removed INSTALLATION Continued Damper Clamp Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Figure 3 Attaching Damper Clamp Damper CONNE...

Страница 8: ...check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PS...

Страница 9: ...t to the ac tion of propane LP gas on larger end of fitting screw burner inlet fitting through hole and into burner manifold see Fig ure 6 Tighten using a wrench If using propane LP gas see Propane LP...

Страница 10: ...tural Gas Installation 1 Thread gas control valve onto burner inlet fitting see Figure 8 Use thread sealant on male threads of burner inlet fitting Hold burner inlet fitting with a wrench to prevent o...

Страница 11: ...upplied with orifice installed for a 24 log set If you have an 18 or 30 set you must change this orifice also See Figure 1 page 5 for product identification Burner Inlet Fitting 1 Remove burner inlet...

Страница 12: ...ystem is leak free 4 When burner is tested and leak free observe individual tongues of flame on burner Note Burner design includes more ports on the outside of the bar Make sure that all ports are cle...

Страница 13: ...and Back Logs Number and style may vary 5 Place smaller top logs onto bottom logs see Figure 17 Leave as much open space between logs as possible to mini mize flame impingement and sooting Note Logs m...

Страница 14: ...Codes ANSI Z233 1 NFPA 54 Air for Combustion and Ventilation If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position and press in Keep control knob press...

Страница 15: ...7 page 14 8 Turn control knob counterclockwise to the ON position Burner should light If burner does not light call a quali fied service person 9 To leave pilot lit and shut off burners only turn cont...

Страница 16: ...ned and checked 3 Separate the logs to allow more flame passage 4 Remove any foreign items from the flame pattern and or check for proper orifice sizing 5 Preheat flue in very cold weather 1 Relieve a...

Страница 17: ...shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat ignit ing operation until air is removed 5 Adjust pilot...

Страница 18: ...ning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top of page...

Страница 19: ...FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready You can also visit our web site at www fmiproducts com Replacement Parts Note Use only or...

Страница 20: ...w fmiproducts com 901265 U 20 Parts Models CVSR18 CVSR24 CPVSR18 and CPVSR24 3 1 8 6 4 2 10 11 12 13 14 15 16 23 17 22 21 20 19 18 7 5 9 9 Oxford Round Oak Logs Amherst Round Oak Logs CPVSR Models Onl...

Страница 21: ...2 1 901243 02 Log Grate 1 2 1 901246 01 Log Grate 5 8 1 901246 02 Log Grate 5 8 1 11 901459 01 Bottom Front Log CPR 18 1 901459 01 Bottom Front Log CPR 24 1 12 901458 01 Bottom Rear Log CR 16 1 90145...

Страница 22: ...www fmiproducts com 901265 U 22 3 13 1 8 6 4 2 10 7 5 9 9 11 12 14a 14a 15b 16b 17f 17e 17a 15d 15f 14b 15c 15a 15e Berkshire Oak Log Set Coventry Oa PARTS Models CVDR18 CVDR24 and cvdr30...

Страница 23: ...sembly 1 8 101628 01 Gas Line 10 Flex 1 9 901431 01 Grate Steps 2 10 901246 01 Log Grate 1 901246 02 Log Grate 1 901246 03 Log Grate 1 11 901681 01 Burner Strap 1 12 901078 01 Nut 8 32 1 13 901076 01...

Страница 24: ...www fmiproducts com 901265 U 24 3 10 1 8 9 4 2 7 15 13 6 5 14 14 22 20 16 17 18 19 21 12 11 Mendocino Oak Log Set PARTS Models BFLT18 and BFLT24...

Страница 25: ...er Pan 1 10 901076 01 Screw 8 32 x 3 8 1 11 901078 01 Nut 8 32 1 12 901681 01 Burner Strap 1 13 901242 01 Damper Clamp Std Assembly 1 14 901431 01 Grate Steps 2 15 901246 01 Log Grate 1 901246 02 Log...

Страница 26: ...ol Ready on off safety Valve Pilot Kit GA9150A For all models Required for remote control operation Contains components for propane LP conversion Purchase these accessories from your local dealer If t...

Страница 27: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 28: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...

Отзывы: