background image

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900203-00, Rev. A  10/2015

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Comfort Flame™ Brand Gas Log Set

Limited One Year Warranty

THE WARRANTY

Innovative Hearth Products Limited One Year Warranty ("IHP") warrants your Comfort Flame brand Gas Log Set ("Product") to be free from defects in materials and work-
manship at the time of manufacture. The logs and grate carry the Limited One Year Warranty. After installation, if covered components manufactured by IHP are found to 
be defective in materials or workmanship during the Limited One Year Warranty period and while the Product remains at the site of the original installation, IHP will, at 
its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale 
price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such 
components. THERE ARE EXCLUSIONS AND LIMITATIONS to this Limited Three Year Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of 
product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Three Year Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be  purchased through a listed supplier of IHP and proof of purchase must be 
provided. The following do not carry the Limited Three Year Warranty but are warranted as follows:

Gas components 

– Repair or replacement for one year from the date of installation.

Remote control 

– Repair or replacement for one year from the date of installation.

Labor coverage 

– Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

This Limited One Year Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 
after replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 
particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited One Year Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this Limited One Year Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 
One Year Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited One Year Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this Limited One Year Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.COMFORTFLAME.US.COM.

Содержание Biltmore18LTN

Страница 1: ...or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage INSTALLER Leave this manual with the appliance CO...

Страница 2: ...ting plate This appliance is not convertible for use with other gases WARNING Do not allow fans to blow directly intotheappliance Avoidanydraftsthatalterburner flame patterns Ceiling fans can create d...

Страница 3: ...upplier s instructions if you cannot reach your gas supplier call the fire department 5 This gas log set may not be installed as a vented appliance in a bedroom or bathroom 6 Before installing in a so...

Страница 4: ...mmonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas product...

Страница 5: ...m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with...

Страница 6: ...Example 2 560 cu ft volume of space x 20 51 200 maximum Btu Hr the space can support 3 Add the Btu Hr of all fuel burning appliances in the space Vent free fireplace _________Btu Hr Gas water heater _...

Страница 7: ...ce in a vented configuration Check your state or local codes WARNING Aqualifiedservicepersonmustinstall heater Follow all local codes WARNING Beforeinstallinginasolidfuel burning fireplace the chimney...

Страница 8: ...WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining wall WARNING This appliance is equipped for either naturalgasorpropane LPgasbutnotboth Ga...

Страница 9: ...accessory to deflect heat away fromyourmantelshelf SeeFigures5 6and7forminimumclearances Heat Resistant Material Figure 6 Minimum Mantel Clearances Without Using Hood Minimum Non Combustible Material...

Страница 10: ...er to fire place floor If not heater will move when you adjust controls Moving heater may cause a gas leak or log misplacement CAUTION Do not pick up heater base assembly bytheburner Thiscoulddamagehe...

Страница 11: ...logs front to back and side to side in fireplace 6 Carefully remove logs without moving heater base 7 Mark screw locations through holes in mounting brackets see Figure 11 If installing in a brick bo...

Страница 12: ...diment trap in supply line as shown in Figure 14 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and heater Locate sedi ment trap where trapped...

Страница 13: ...all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valv...

Страница 14: ...in middle log 2 and front log 1 See Figure 23 for Biltmore24LTN LTP See Figure 22 for Biltmore18LTN LTP 7 Add volcanic stone around base of heater if desired Do not place any volcanic stone on logs o...

Страница 15: ...g 4 Figure 21 Installing Crossover Log 5 Biltmore24LTN LTP Shown Crossover Log 4 Front Log 1 Crossover Log 5 Figure 22 Installing Crossover Log 5 and Log 6 Biltmore18LTN LTP Only Crossover Log 4 Front...

Страница 16: ...age personal injury or loss of life WARNING If fireplace has glass doors never operate this heater with glass doors closed If you operateheaterwithdoorsclosed heatbuildupinside fireplace will cause gl...

Страница 17: ...ot MAIN BURNER Periodically inspect all burner flame holes with the heater running All slotted burner flame holes should be open with yellow flame present All round burner flame holes should be open w...

Страница 18: ...2 Inspect burner pilot and primary air inlet holes on injector holder for dust and dirt see Figure 28 3 Blow air through the ports slots and holes in the burner 4 Check the injector holder located at...

Страница 19: ...heat for propane LP units propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local propane LP or natural gas supplier 4 The description of the part 5 The qua...

Страница 20: ...Control knob not in PILOT position 3 Control knob not pressed in while in PILOT position 4 Air in gas lines when installed 5 Depleted gas supply propane LP only 6 ODS pilot is clogged 7 Gas regulator...

Страница 21: ...or replace burner orifice White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture polish wax carpet cleaners etc may turn into white powder...

Страница 22: ...alve assembly This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications If positioning the thermostat sensing bulb elsewhere follow the...

Страница 23: ...iable Gas Type Natural Ignition Piezo Manifold Pressure 3 5 W C Inlet Gas Pressure in of water Maximum 10 5 W C Minimum 5 W C For the purpose of input adjustment Biltmore18LTP 16 000 30 000 Btu hr Var...

Страница 24: ...IT OAK MODELS BILTMORE18LTN BILTMORE18LTP BILTMORE24LTN AND BILTMORE24LTP 9 23 23 23 10 8 13 14 15 4 5 1 2 Peg positions vary according to model 11 12 19 21 21 24 22 20 6 7 25 18 23 17 16 7 Cat No Mod...

Страница 25: ...Burner Orifice Injector 1 J3605 Burner Orifice Injector 1 J3607 Burner Orifice Injector 1 J3612 Burner Orifice Injector 1 14 J8089 Burner Retainer Spring 1 15 J3763 Burner 1 J3784 Burner 1 16 J3697 Th...

Страница 26: ...allation of this appliance Use of non approved accessory part kit can result in poor performance and safety hazards FIREPLACE HOOD BLACK Cat No F1764 Model GA6050 For all models Helps deflect heat awa...

Страница 27: ...e to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provide...

Страница 28: ...nce uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local d...

Отзывы: