10
Sync DY10
When the
Active
box is ticked, DY10 sends out pairing information for the
Main Channel continuously. In order for pairing information for the Con-
necting Channel to be transferred to a Comfort Digisystem product, the
Main Channel must be set and activated.
Setting the Connecting Channel
The Connecting Channel is used in a dual channel system. The Main
Channel and Connecting Channel cannot be tuned to the same or ad-
jacent frequency bands. You can opt to set the Main Channel to a high
frequency and the Connecting Channel to a low frequency, or vice versa.
Check which frequencies the Comfort Digisystem products that are to be
used in the premises are designed for.
If the Comfort Digisystem products are synchronised incorrectly or chan-
nel and frequency settings are incompatablewith the relevant channel
setting are not designed for these frequencies or frequency combina-
tions, the product displays an error message the system will display an
error message.
When the
Active
box is ticked, DY10 sends out pairing information for the
Connecting Channel continuously. If the Connecting Channel is not to be
used, the
Active
box should not be ticked.