background image

Programmer DT05

6

Pairing

When 

Pairing is selected, the DT10 can be set to pairing 

mode by pressing the push-button for two seconds. 

If 

Pairing isn’t selected, pairing mode cannot be enabled 

with the push-button. To override this, (if the Receiver 

DT10 needs to be reconfigured or if new pairing infor-

mation needs to be received), press and hold the push-

button on the Receiver DT10 for 2 seconds within  

10 seconds of it having been connected to a hearing  

instrument or a Programmer DT05. This sets the 

Receiver DT10 to Pairing mode and it is then ready to 

receive new settings from the Programmer DT05.

The Receiver DT10 can receive but not transmit pairing 

information. To pair the Receiver DT10 with your

Comfort Digisystem transmitter the Receiver DT10 must 

be connected either to your hearing instrument

or to the Programmer DT05. 

If you enable 

Always on and at the same time disable 

Pairing, the push-button on the Receiver DT10 becomes 

inoperable. 

Always on

The setting 

Always on, disables the off-function of the 

push-button, leaving the Receiver DT10 always on. The 

Receiver DT10 is turned off when turning off the Hearing 

aid. 

Send all

To configure a Receiver DT10 with all settings in the 

display of the Programmer DT05 select 

Send all. If you 

choose 

Send all, you will receive the warning “All set-

tings in DT10 will be overwritten”. Only select 

Yes if you 

want to overwrite all data in your Receiver DT10.

Settings

 

HA scanner

 

The Frequency scanner is used for detecting how  

 

much interference there is from a hearing aid,  

 

within the frequency band that the Receiver DT10  

 

is operating in. 

 Language

 

For selection of menu language.

 

Factory Reset

 

DT05: Resets the Programmer DT05 to its default  

 settings.

 

DT10: Resets the Receiver DT10 to its default  

 

settings, which means that also all pairing  

 

information is deleted. The Receiver DT10 must be  

 

set to pairing mode in order to be reset. 

 

To prevent eaves-dropping a new code key must be  

 generated.

About

Software information.

Example: 

Make a new eavesdrop secure configuration 

with one Microphone DM10 and two Receiver DT10s 

using the Programmer DT05:

1.  Put one of the Receiver DT10s into the Programmer  

 DT05.

2.  Start the Programmer DT05 and connect head 

 

phones or a neck loop to be able to listen. 

3.  Activate pairing mode for the DT10 by pressing the  

 

push-button for 2 seconds.  

 

In the headphones/neckloop you receive an acoustic  

 

indication:    

 

    

4.  Start the Microphone DM10 and open the menu.  

 Select 

Communication/Pairing/New code key and  

 answer 

Yes if you want to create a new code key and  

 

transmit it. 

5.  The Receiver DT10 confirms success- 

 

ful pairing with an acoustic indication:       

• •

6.  Remove the paired DT10 and connect the other  

 

DT10 into the Programmer DT05.

7.  Activate pairing mode on the DT10 by pressing the  

 

push-button for 2 seconds. 

 

In the headphones/neckloop you receive an acoustic  

 

indication:    

 

    

8.  Open the menu on the DM10 and select 

 

Communication/Pairing/Send info. 

9.  The Receiver DT10 confirms success- 

 

ful pairing with an acoustic indication:      

• • 

Содержание Comfort Digisystem Programmer DT05

Страница 1: ...Comfort Digisystem User manual Comfort Digisystem Programmer DT05 North America English...

Страница 2: ...unctions Programmer DT05 professional tool 4 4 Included accessories 4 5 Programmer DT05 5 6 Menu Programmer DT05 5 7 Instructions HA scanner in Programmer DT05 6 8 Battery maintenance 8 9 Technical da...

Страница 3: ...to CSA Standard for Safety for Audio Video and Similar electronic apparatus Safety Requirements CAN CSA C22 2 No 60065 03 Issued 2003 04 01 Ed 1 Amendment 1 2006 Intertek ETL Control number 4002355 WA...

Страница 4: ...On Off Pairing button Menu control Socket for headphones earphones Charging socket Volume button Volume button Function indicator Socket for neckloop 3 Functions Programmer DT05 optional professional...

Страница 5: ...nable R R M enable R M Tone ind Auto sleep Pairing Always on Send all Settings Language Factory Reset About Back relates to both the main menu and submenus Here you can choose to return to the menu an...

Страница 6: ...our Receiver DT10 Settings HA scanner The Frequency scanner is used for detecting how much interference there is from a hearing aid within the frequency band that the Receiver DT10 is operating in Lan...

Страница 7: ...dicator The white horizental line indicates an average value of RSSI over the whole frequency range Use the graduation bar to the right to determine how strong the interference is If the level of inte...

Страница 8: ...enough time reach a state when the battery deep discharges unless the charger is connected To avoid this we recommend that the battery is charged at least every 6 months 9 Technical data Programmer DT...

Страница 9: ...you purchased your product outside the territory see your retailer for war ranty information Product Registration Please complete sign and mail the Product Registra tion Card packed with your unit It...

Страница 10: ...subject to impact by another object or dropped or the apparatus has been exposed to rain or moisture or does not operate normally 13 Start listening at a low volume 14 Too high a volume can seriously...

Страница 11: ...ox154 SE 301 05 Halmstad Sweden Tel 46 0 35 260 16 00 Fax 46 0 35 260 16 50 Local US office Comfort Audio Inc 350 South Northwest Hwy Ste 300 Park Ridge IL 60068 USA T 847 656 5450 usa comfortaudio co...

Отзывы: