6. Permissible piping for recommended combinations.
6.1.
Limit the number of bends in piping to less than 3.
6.2.
Table 2
– Maximal distance of pipeline
Table 2
Model
FCA24-1A
FCA36-1A
FCA54-1A
Max length (ft/m)
39/12
49/15
49/15
Max height (ft/m)
26/8
26/8
26/8
Max elbow (pcs)
10
10
10
6.3.
Use vacuum pump to exhaust air in pipeline.
6.4.
When the piping is longer than 26in/8m, add refrigerant as shown in Table 3.
Table 3
Liquid line diameter (in or mm) Charged weight (oz/in or g/m)
Ф0.3 / Ф6.3
0.34 or 30.0
Ф0.4 / Ф9.5
0.70 or 65.0
Ф0.5 / Ф12.7
1.28 or 120.0
CONDENSATE DRAIN
1. Be sure the unit is reasonably level and pitched toward the drain to ensure proper drainage.
2. Connect the condensate drain pipe to the coupling, see Fig.9.
3. The indoor unit uses gravity to drain; therefore the piping outside the unit should slope
downward.
4.
“Important”, avoid draining as shown in Fig.10, A, B, C. Follow proper draining as shown in
Fig.10D.
Fig.9