1. This unit is designed for installation in standard double hung windows

with actual opening widths of 22  to 36  . The upper and lower sash

must open sufficiently to allow a clear vertical opening of 14  from the

bottom of the sash to the window sill.

2. If storm window presents interference, fasten a 2  wide wood strip(not

included) (OUTER SILL) to the inner window sill across the full width of

the sill. The wood strip should be thick enough to raise the height of

the window sill so that the unit can be installed without interference by

the storm window frame (STORM WINDOW FRAME) or wood strip

(OUTDOORS) to help condensation to drain properly to the outside.

3. Install a second wood strip (approximately 6  long by 1-1/2  wide

and same thickness as first strip) in the center of the outer sill flush

against the back off the inner sill. This will raise basepan angle .

4. If the distance between STORM WINDOW FRAME and WOOD STRIP

MOUNTED ON TOP OF INNER SILL is more than 1  , two of wood

strip are not necessary.

INNER

SILL

OUTER

SILL

I

N

D

O

O

R

S

O

U

T

D

O

O

R

S

WOOD STRIP

MOUNTED ON

TOP OF INNER SILL

WOOD STRIP

FOR BASEPAN

ANGLE

STORM

WINDOW FRAME

1  MAX.

3/4  CLEARANCE

I

N

D

O

O

R

S

O

U

T

D

O

O

R

S

INNER

SILL

OUTER

SILL

LOCATING UNIT IN

WINDOW

Open the window and mark center line on the

center of the inner sill.

CENTER LINE

INNER SILL

INDOOR SIDE

ATTACH BASEPAN

ANGLE

CENTER LINE

SHORT SCREW13/32"

INNER SILL

OUTER SILL

SHORT SIDE

BASEPAN ANGLE

8

8

OUTSIDE

INSIDE

Install the basepan angle behind the inner window sill, with

the short side of basepan angle as shown. Use the 2 short

screws13/32" provided.

The basepan angle helps to hold unit securely in place.

Be sure to place basepan angle edge flush against back

of inner sill.

2

Содержание COMFORT AIRE RAD-61B

Страница 1: ...C M Y CM MY CY CMY K 0010562911 TEMPERATURE 1 2 3 4 10 9 8 7 6 5 FAN ONLY MIN COOL MAX COOL SPEED LOW HI OFF ON Wait 3 Minutes Before Restarting POWER RG 61A ...

Страница 2: ...C M Y CM MY CY CMY K ...

Страница 3: ...C M Y CM MY CY CMY K 1 ...

Страница 4: ...C M Y CM MY CY CMY K ...

Страница 5: ...C M Y CM MY CY CMY K 1 1 2 4 4 5 5 6 7 8 13 8 8 13 14 18 15 15 16 18 19 20 20 21 ...

Страница 6: ... use 1 Press reset button 2 Press test button unit should trip 3 Press reset button again for use Do not use if above test fail In the event this device trips the cause of the malfunction is to be corrected before further use of the device Important ...

Страница 7: ...C M Y CM MY CY CMY K 5 5 ...

Страница 8: ... 6 2 way airflow control panel easy access filters MODEL RG 61A TEMPERATURE 1 2 3 4 10 9 8 7 6 5 FAN ONLY MIN COOL MAX COOL SPEED LOW HI OFF ON Wait 3 Minutes Before Restarting POWER 2 MODE Set Switch 5 How The Unit Drains ...

Страница 9: ...C M Y CM MY CY CMY K 7 Fig 1 TEMPERATURE 1 2 3 4 10 9 8 7 6 5 FAN ONLY MIN COOL MAX COOL SPEED LOW HI OFF ON POWER ...

Страница 10: ... the HI or the LOW setting 2 Set the thermostat control to the temperature mark FAN ONLY Normal cooling 1 Turn the SPEED mode switch to the HI or the LOW setting 2 Set the thermostat control to the desire temperature the mid point is a good starting position If the room temperature is not satisfactory after a reasonable time adjust the control to a warmer or cooler setting as appropriate Maximum c...

Страница 11: ...C M Y CM MY CY CMY K 9 ...

Страница 12: ...C M Y CM MY CY CMY K 10 window seal gasket short screws 13 32 wood screws 31 32 Model RG 61A top rail ...

Страница 13: ...sten the curtains to the unit with 8 short screws 13 32 Install top rail with 3 short screws13 32 ASSEMBLE CURTAINS TOP RAIL TEMPERATURE 1 2 3 4 10 9 8 7 6 5 FAN ONLY MIN COOL MAX COOL SPEED LOW HI OFF ON Wait 3 Minutes Before Restarting POWER RG 61A 12 3 5 13 3 8 36 22 12 7 16 18 9 16 1411 16 5 3 25 1 2 ...

Страница 14: ...strip in the center of the outer sill flush against the back off the inner sill This will raise basepan angle 4 If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1 two of wood strip are not necessary INNER SILL OUTER SILL I N D O O R S O U T D O O R S WOOD STRIP MOUNTED ON TOP OF INNER SILL WOOD STRIP FOR BASEPAN ANGLE STORM WINDOW FRAME 1 MAX 3 4 ...

Страница 15: ... behind the upper guide of the air conditioner WINDOW FRAME UPPER GUIDE BOTTOM GUIDE BASEPAN ANGLE ABOUT 1 4 INSTALL THE SEAL GASKET AND SASH LOCK Extend the side curtains to fill the window opening using 4 wood screws 31 32 to secure them Cut the seal gasket to the window width Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room Fasten the ba...

Страница 16: ... below 40 o C 104 o F 4 Rinse and gently shake the water from the filter and let it dry before replacing it Always use a soft cloth dampened with water or mild soap and water solution to wipe the front of the cabinet To clean the front panels or the cabinet DO NOT use harsh chemicals abrasives ammonia chlorine bleach concentrated detergents solvents or metal scouring pads DO NOT use your air condi...

Страница 17: ...C M Y CM MY CY CMY K 15 ...

Страница 18: ...C M Y CM MY CY CMY K 16 see page 8 see page 18 ...

Отзывы: