Technical Specifications -
GDD92C
REV CODE
REVISION
NOM. CFM X 100
2 TON ADD ON COOLING
3 TON ADD ON COOLING
4 TON ADD ON COOLING
5 TON ADD ON COOLING
CABINET WIDTH
A = 14.5” WIDTH
B = 17.5” WIDTH
C = 21.0” WIDTH
D = 24.5” WIDTH
BTUH INPUT
HEATING INPUT X 1000
GAS
G = GAS FURNACE
CONFIGURATION
DD = DOWNFLOW
AFUE
80 = 80% EFFICENCY
92 = 92% EFFICENCY
95 = 95% EFFICENCY
96 = 96% EFFICENCY
STAGES/MOTOR
G DD 92 C
G DD 92 C 00 44 55 BB 33 M
M
A =SINGLE STAGE PSC
C =SINGLE STAGE CONSTANT TORQUE
T = TWO STAGE VARIABLE SPEED ECM
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output *
(Btuh)
AFUE
(ICS)
Nominal*
Cooling
Capacity
(tons)
Gas
Inlet
(in.)
Volts/
Hertz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
DOWNFL
OW
GDD92C045B3M
44,000
42,000
92.1%
1.5-3
1/2
120-60-1
15
6.8
40
123.5
GDD92C070B3M
66,000
63,000
92.1%
1.5-3
1/2
120-60-1
15
6.8
40
129.5
GDD92C090C4M
88,000
84,000
92.1%
2.5-4
1/2
120-60-1
15
8.4
40
152.0
Note: For vent length and clearances to combustibles, please reference installation instructions.