COMFORT-AIRE CD-101Q Скачать руководство пользователя страница 15

OWNER’S MANUAL  -  

CD-81Q, 101Q

14

AIR CONDITIONER FEATURES

TO ADJUST FAN SPEEDS:

Press     to select the Fan Speed in four steps-Auto, 

Low, Med or High. Each time the button is pressed, 

the fan speed mode is shifted.

TO SELECT THE OPERATING MODE:

To choose operating mode, press      Mode button.Each 

time you press the button, a mode is selected in a 

sequence that goes from Auto, Cool, Dry and Fan. The 

indicator light beside will be illuminated and remain on 

once the mode is selected.  

The unit will initiate automatically the Energy Saver 

function under Cool, Dry, Auto(only Auto-Cooling and 

Auto-Fan) modes.

To operate on Auto feature:

When you set the air conditioner in AUTO mode, it will 

automatically select cooling, heating(cooling only models 

without), or fan only operation depending on what 

temperature you have selected and the room temperature.

 

The air conditioner will control room temperature 

automatically round the temperature point set by you.

In this mode, the fan speed cannot be adjusted, it starts 

automatically at a speed according to the room 

temperature. 

To operate on Fan Only:

Use this function only when cooling is not desired,such 

as for room air circulation or to exhaust stale air(on 

some models). (Remember to open the vent during this 

function, but keep it closed during cooling for maximum 

cooling efficiency.) You can choose any fan speed you 

prefer.

During this function, the display will show the actual

 

room temperature, not the set temperature as in the

 

cooling mode.

In Fan only mode ,the temperature is not adjusted.

To operate on Dry mode:

In this mode, the air conditioner will generally operate 

in the form of a dehumidifier. Since the conditioned 

space is a closed or sealed area, some degree of 

cooling will continue.

SLEEP FEATURE:

Press      Sleep button to initiate the sleep mode. In 

this mode the selected temperature will increase by 

O

O

2 F/1(or 2) C 30 minutes after the mode is selected. 

O

The temperature will then increase by another 2 F/

O

1(or 2) C after an additional 30 minutes. T his n ew

t emperature w ill be maintained for 6  hours  before  it

 returns  to  the  originally selected temperature. This 

ends the Sleep mode and  the u nit w ill c ontinue t o

o perate  as originally programmed. The Sleep mode

program can be cancelled at any time during 

operation by pressing the Sleep button again.

 Press      Check filter button to initiate this feature.

 

 

This feature is a reminder to clean the Air Filter for

 

 

more efficient operation. The LED(light) will illumi-

 nate after 250 hours of operation. To reset after 

 cleaning the filter, press the Check Filter button and

 the light will go off.

CHECK FILTER FEATURE:

ENERGY SAVER FEATURE:

Press     Energy saver button to initiate this function.

This function is available on COOL, DRY, AUTO 

(only AUTO-COOLING and AUTO-FAN) modes.The 

fan will continue to run for 3 minutes after the 

compressor shuts off.The fan then cycles on for 2 

minutes at 10 minute intervals until the room 

temperature is above the set temperature, at which 

time the compressor turns back on and Cooling 

Starts.

FOLLOW ME FEATURE:

(on some models)

Light flashing

Follow

   Me

This feature can be activated from the remote 

control ONLY. The remote control serves as 

a remote thermostat allowing for the precise 

temperature control at its location.

To activate the Follow Me feature, point the remote 

control towards the unit and press the Follow Me 

button. The remote display is actual temperature at 

its location. The remote control will send this signal 

to the air conditioner every 3 minutes interval until 

press

ing

 the Follow Me button again.

 

If the unit 

does not receive the Follow Me signal during any 7 

minute interval, the unit will beep to indicate the 

Follow Me mode has ended. 

     When the unit is on or off, first press       Timer button, the 

     TIMER ON indicator light illuminates. It indicates the Auto 

     Start program is initiated. 

     When the time of TIMER ON is displayed 

     Press or hold the UP or DOWN button to change the Auto 

     time by 0.5 hour increments, up to 10 hours,then at 1 hour 

     increments up to 24 hours.The control will count down the 

     time remaining until start. 

     The selected time will register in 5 seconds, and the system 

     will automatically revert back to display the previous 

     temperature setting or room temperature when the unit is 

     on.(when the unit is off,there is no display.)

     Turning the unit ON or OFF at any time or adjusting the 

     timer setting to 0.0 will cancel the Auto Start/Stop timed 

     program.

,press the Timer 

     button again, the TIMER OFF indicator light illuminates. 

     It indicates the Auto Stop program is initiated. 

TIMER: AUTO START/STOP FEATURE:

14

Содержание CD-101Q

Страница 1: ...ers com OWNER S MANUAL Room Air Conditioner with R 410A CD 81M CD 101M Heat Controller 1900 Wellworth Ave Jackson MI 49203 517 787 2100 www heatcontroller com OWNER S MANUAL Room Air Conditioner with R 410A CD 81M CD 101M OWNER S MANUAL Room Air Conditioner with R 410A CD 81Q CD 101Q ...

Страница 2: ...re due to excess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and electric sh...

Страница 3: ...er of fire or electric shock Operation without filters may cause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure Hold the plug by the head of the power plug w...

Страница 4: ...t If the window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this unit When handling the air conditioner be careful to avoid cuts from sharp metal fi...

Страница 5: ...cian if you are in doubt as to whether the appliance is pro perly grounded DO NOT modify power supply cord plug If it does not fit outlet have a proper outlet installed by a qualified electrician DO NOT have a fuse in the neutral or grounding circuit A fuse in the neutral or grounding circuit could result in an electrical shock DO NOT use an extension cord with this appliance Failure to follow the...

Страница 6: ...n right 15 1 2 inches minimum width 16 1 4 inches maximum width for casement windows 21 1 4 inches minimum height with window panel retainer 20 5 16 inches minimum height window panel retainer removed 39 7 16 inches maximum height NOTE Height measurement must be of a clear opening above mounting platform In some cases due to a variety of stop and track arrangements the above dimensions may vary sl...

Страница 7: ...OWNER S MANUAL CD 81Q 101Q 6 INSTALLATION INSTRUCTIONS 1 4 11 16 Window track Window seal Platform tab Alternate screw location depending on the stool depth 6 ...

Страница 8: ...OWNER S MANUAL CD 81Q 101Q 7 INSTALLATION INSTRUCTIONS 7 ...

Страница 9: ...OWNER S MANUAL CD 81Q 101Q INSTALLATION INSTRUCTIONS 1 8 8 ...

Страница 10: ...nergy star models In order to minimize air leaks and ensure optimal insulation it is necessary to install the included R1 hardware to the plastic window panel Follow the instructions below Step 1 After the unit is installed to the window measure the inner height of the panel frame to the top of the unit Step 2 Remark a line on the provided R1 hardware according to the measure height in step 1 then...

Страница 11: ...OWNER S MANUAL CD 81Q 101Q INSTALLATION INSTRUCTIONS 3 4 or 1 3 4 or 1 or 10 10 ...

Страница 12: ...Q 101Q 11 INSTALLATION INSTRUCTIONS 11 6 Securely attach a siding protection board to the side of the house where the platform assembly hits the house The siding protection board should be long enough to span 2 wall studs ...

Страница 13: ...ont First reconnect the coupler plugs make the exhause control positioned through the front in the proper location Then replace the retaining screws that hold the panel in place Do not push or pull the fron panel louvers 17 Install the R1 hardware Only applicable to Energy star models ...

Страница 14: ...ELECTRONIC CONTROL OPERATING INSTRUCTIONS 13 TO TURN UNIT ON OR OFF Press ON OFFbutton toturn unito n or off NOTE The uni t wi ll ini tia te automatically the Energy Saver function under Cool Dry Auto only Auto Cooling and Auto Fan modes CLEAN AIR FEATURE on some models Press Clean Air button the ion generator is energized and will help to removepollen andimpurities from the air and trap them in t...

Страница 15: ...y programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again Press Check filter button to initiate this feature This feature is a reminder to clean the Air Filter for more efficient operation The LED light will illumi nate after 250 hours of operation To reset after cleaning the filter press the Check Filter button and the light will go off C...

Страница 16: ...n during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other press and hold the Left and Right Temp Timer buttons at the same time for 3 seconds CARE AND CLEANING CAUTION Clean your air conditioner occasionally to keep it looking new Be sure to unplug the unit before cleaning to prevent shock or fire hazards Air Filte...

Страница 17: ... breaker Plug Current Device Tripped Press the RESET button Problem Air from unit does not feel cold enough Set to a Lower temperature O O Room temperature below 62 F 17 C Cooling may not occur until room temperature O O rises above 62 F 17 C Thermostat set too cold for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a Higher setting Temperature sensing behind a...

Страница 18: ...en unit is cooling Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty air filter air restricted Clean air filter Air movement sound This is normal If too loud set to a slower FAN setting Outside temperature extremely hot Set FAN speed to a Higher setting ...

Страница 19: ...ss warranty begins on the date of shipment from the factory REMEDY PROVIDED BY THE LIMITED EXPRESS WARRANTY The sole remedy under the Limited Warranty is replacement of the defective unit Labor to diagnose and replace the defective unit is not covered by this Limited Express Warranty If for any reason the replacement product is no longer available during the warranty period Comfort Aire shall have...

Страница 20: ...H LQVWDOOHU LV UHVSRQVLEOH IRU YHULI LQJ GLPHQVLRQDO GDWD RQ WKH DFWXDO SURGXFW SULRU WR EHJLQQLQJ DQ LQVWDOODWLRQ SUHSDUDWLRQV QFHQWLYH DQG UHEDWH SURJUDPV KDYH SUHFLVH UHTXLUHPHQWV DV WR SURGXFW SHUIRUPDQFH DQG FHUWLILFDWLRQ OO SURGXFWV PHHW DSSOLFDEOH UHJXODWLRQV LQ HIIHFW RQ GDWH RI PDQXIDFWXUH KRZHYHU FHUWLILFDWLRQV DUH QRW QHFHVVDULO JUDQWHG IRU WKH OLIH RI D SURGXFW 7KHUHIRUH LW LV WKH UHVS...