![COMFORT-AIRE A-VFH30QB-1 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/comfort-aire/a-vfh30qb-1/a-vfh30qb-1_service-manual_2641634037.webp)
Service Manual -
VFH-B 30/36/42 Series
37
3RVVLEOH&DXVHV
'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV
7URXEOHVKRRWLQJ
6HWWHPSHUDWXUHLVLPSURSHU
2EVHUYHWKHVHWWHPSHUDWXUHRQUHPRWHFRQWUROOHU$GMXVWWKHVHWWHPSHUDWXUH
5RWDWLRQVSHHGRIWKH,'8IDQ
PRWRULVVHWWRRORZ
6PDOOZLQGEORZ
6HWWKHIDQVSHHGDWKLJKRUPHGLXP
)LOWHURILQGRRUXQLWLVEORFNHG
&KHFNWKH¿OWHUWRVHH
if
EORFNHG
&OHDQWKH¿OWHU
,QVWDOODWLRQSRVLWLRQIRULQGRRUXQLW
DQGRXWGRRUXQLWLVLPSURSHU
&KHFNZKHWKHUWKHLQVWDOODWLRQSRV
i
WLRQLVSURSHU
DFFRUGLQJWRLQVWDOODWLRQUHTXLUHPHQWIRUDLU
FRQGLWLRQHU
$GMXVWWKHLQVWDOODWLRQSRVLWLRQ
5HIULJHUDQWLVOHDNLQJ
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJFRROLQJLV
KLJKHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJKHDWLQJLV
ORZHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
8QLWVSUHVVXUHLVPXFKORZHUWKDQUHJXODWHG
UDQJH
)LQGRXWWKHOHDNDJHFDXVHVDQGGHDOZLWKLW
$GGUHIULJHUDQW
0DOIXQFWLRQRIZD\YDOYH
%ORZFROGZLQGGXULQJKHDWLQJ
5HSODFHWKHZD\YDOYH
0DOIXQFWLRQRIFDSLOODU\
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJFRROLQJLV
KLJKHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
'LVFKDUJHGDLUWHPSHUDWXUHGXULQJKHDWLQJLV
ORZHUWKDQQRUPDOGLVFKDUJHGZLQGWHPSHUDWXUH
8QLW
s
SUHVVXUHLVPXFKORZHUWKDQUHJXODWHG
UDQJH,IUHIULJHUDQWLVQ¶WOHDNLQJSDUWRIFDSLOODU\
LVEORFNHG
5HSODFHWKHFDSLOODU\
)ORZYROXPHRIYDOYHLV
LQVXI¿FLHQW
7KHSUHVVXUHRIYDOYHVLVPXFKORZHUWKDQWKDW
VWDWHGLQWKHVSHFL¿FDWLRQ
2SHQWKHYDOYHFRPSOHWHO\
0DOIXQFWLRQRIKRUL]RQWDORUL]RQWDOORXYHUFDQ¶WVZLQJ
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
GHWDLOV
0DOIXQFWLRQRIWKH,'8IDQPRWRU 7KH,'8IDQPRWRUFDQ¶WRSHUDWH
5HIHUWRWURXEOHVKRRIRUPDLQWHQDQFH
PHWKRGLQGHWDLOV
0DOIXQFWLRQRIWKH2'8IDQPRWRU7KH2'8IDQPRWRUFDQWRSHUDWH
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
GHWDLOV
0DOIXQFWLRQRIFRPSUHVVRU
&RPSUHVVRUFDQWRSHUDWH
5HIHUWRSRLQWRIPDLQWHQDQFHPHWKRGIRU
GHWDLOV
9.3 Maintenance Method for Normal Malfunction
1. Air Conditioner Can't be Started Up
2. Poor Cooling (Heating) for Air Conditioner
3. Horizontal Louver Can't Swing
3RVVLEOH&DXVHV
'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV
7URXEOHVKRRWLQJ
1RSRZHUVXSSO\RUSRRU
FRQQHFWLRQIRUSRZHUSOXJ
$IWHUHQHUJL]DWLRQRSHUDWLRQLQGLFDWRULVQ¶WEULJKW
DQGWKHEX]]HU
does not emit
VRXQG
&RQ¿UPZKHWKHULWVGXHWRSRZHUIDLOXUH,I\HV
ZDLWIRUSRZHUUHFRYHU\,IQRWFKHFNSRZHU
VXSSO\FLUFXLW
:URQJZLUHFRQQHFWLRQEHWZHHQ
LQGRRUXQLWDQGRXWGRRUXQLW
RUSRRUFRQQHFWLRQIRUZLULQJ
WHUPLQDOV
8QGHUQRUPDOSRZHUVXSSO\FLUFXPVWDQFHV
RSHUDWLRQLQGLFDWRULVQWEULJKWDIWHUHQHUJL]DWLRQ
&KHFNWKHFLUFXLWDFFRUGLQJWRFLUFXLWGLDJUDP
DQGFRQQHFWZLUHVFRUUHFWO\0DNHVXUHDOO
ZLULQJWHUPLQDOVDUHFRQQHFWHG¿UPO\
0DNHVXUHWKHDLUFRQGLWLRQHULVJURXQGHG
UHOLDEO\
0DNHVXUHZLUHVRIDLUFRQGLWLRQHU
are
FRQQHFWHG
correctly
&KHFNWKHZLULQJLQVLGHDLUFRQGLWLRQHU&KHFN
ZKHWKHUWKHLQVXODWLRQOD\HURISRZHUFRUGLV
GDPDJHGLI\HVSODFHWKHSRZHUFRUG
0RGHOVHOHFWLRQIRUDLUVZLWFKLV
LPSURSHU
$IWHUHQHUJL]DWLRQDLUVZLWFKWULSVRII
6HOHFWSURSHUDLUVZLWFK
0DOIXQFWLRQRIUHPRWHFRQWUROOHU
$IWHUHQHUJL]DWLRQRSHUDWLRQLQGLFDWRULVEULJKW
ZKLOHQRGLVSOD\RQUHPRWHFRQWUROOHURUEXWWRQV
KDYHQRDFWLRQ
5HSODFHEDWWHULHVIRUUHPRWHFRQWUROOHU
5HSDLURUUHSODFHUHPRWHFRQWUROOHU
3RVVLEOH&DXVHV
'LVFULPLQDWLQJ0HWKRG$LUFRQGLWLRQHU6WDWXV
7URXEOHVKRRWLQJ
:URQJZLUHFRQQHFWLRQRUSRRU
FRQQHFWLRQ
&KHFNWKHZLULQJVWDWXVDFFRUGLQJWRFLUFXLW
GLDJUDP
&RQQHFWZLUHVDFFRUGLQJWRZLULQJGLDJUDPWR
PDNHVXUHDOOZLULQJWHUPLQDOVDUHFRQQHFWHG
¿UPO\
6WHSSLQJPRWRULVGDPDJHG
6WHSSLQJPRWRUFDQWRSHUDWH
5HSDLURUUHSODFHVWHSSLQJPRWRU
0DLQERDUGLVGDPDJHG
2WKHUVDUHDOOQRUPDOZKLOHKRUL]RQWDOORXYHU
FDQWRSHUDWH
5HSODFHWKHPDLQERDUGZLWKWKHVDPHPRGHO
Electric leakage for air
conditioner
After energization, room circuit breaker trips off
at once
Содержание A-VFH30QB-1
Страница 2: ......