Sensors Wx7xx with WiFi interface

  

QUICK START MANUAL

 

 

 

PRODUCT DESCRIPTION 

 

Sensors Wx7xx with WiFi interface

 are designed to measure temperature, relative humidity, barometric pressure, CO

2

 concentration 

of the air in the non-aggressive environment. Communication with the sensor is done via wireless WiFi network. Sensor is designed to send 
measured values to online portal COMET Cloud. It can provide values via www pages and by the Modbus TCP protocol as well. Sensors 
continuously evaluate measured values, in case of limits are exceeded, alarm e-mail is sent and set acoustic or optical signalisation. 

Measured values and alarm states are shown at the LCD display. 

 

Device type  Measured values 

Construction 

 

 

 

W0710

 

T

 

With connected temperature sensor 

 

W0711

 

T

 

Connector for external Pt1000/C probe

 

W0741

 

T

 

Connectors for up to four external Pt1000/C probes 

W3710

 

T + RH + CV

 

With connected temperature and relative humidity sensors 

W3711 

T + RH + CV

 

Connector for external Digi/E probe 

W3721

 

T + RH + CV

 

Connectors for two external Digi/E probes 

W4710 

T + RH + P + CO

2

 + CV 

With  connected  temperature,  relative  humidity  sensor,  internal  sensors  for  barometric  pressure 
and CO

2

 concentration 

W5714 

CO

2

 

Internal sensor CO

2

 

W7710 

T + RH + P + CV 

With connected temperature, relative humidity sensors and internal barometric pressure sensors 

 

 

 

 

   

T…temperature, RH…relative humidity, P…barometric pressure, CO

… concentration of CO

2

 in the air 

CV…computed values

 (dew point, absolute and specific humidity, mixing ratio, specific enthalpy, humidex)  

 

INSTALLATION AND CONNECTION

 

 

Fasten 

the sensor directly to the wall using two screws or insert it into the lockable holder LP100 (optional accessories). The sensor 

is designed for a fixed installation. Keep the probes and device away from sources of electromagnetic interferences. 

 

always install the devices vertically with the antenna upwards in places with sufficient quality of the WiFi signal (check e.g. via 

a WiFi-enabled cell phone). Please make sure that the environmental characteristics correspond to the operating conditions 

 

connect the probes. The maximum cable length of the Digi/E probe is 15 m. Recommended cable length of the Pt1000/C probes 

is up to 15 m (max. 30 m) 

 

connect supplied power source into plug socket (use supplied cable to connect device into USB-C connector) 

 

DEVICE SETUP 

 

To be able use all features of the device, it is mandatory to setup device. This task can be done by wireless connection via integrated 
access point or via USB cable. Setup via USB cable can be done from software which is free for download at 

www.cometsystem.com

Setup procedure via integrated access point: 

 

newly purchased device is set into access point mode. This is signalised by symbol 

AP

 at the LCD display. In case of this symbol 

is not shown or there is symbol 

CL

 shown, please switch device mode manually by the buttons (see chapter 

“B

uttons control

). 

 

enable WiFi inside your laptop or cell phone and connect to access point with name 

WiFiSensor_xxxxxxxx

. In case of cell 

phone is used, it is recommended to switch off mobile data connection. 

 

open web browser and insert address 

http://192.168.3.1

 or 

www.wifisensor.net

 

 

press setup button 

at the main page to start device configuration. At the first step select 

Network

 

-

 

Wifi client

 

-

 

Scan 

and insert SSID a password for your WiFi network.

 

 

activate connection into COMET Cloud at the menu item 

Cloud - Cloud mode 

and select COMET Cloud mode. Registration 

card for adding device into your account under COMET Cloud is a part of shipment. 

 

at the menu 

Channels

 it is possible to set alarm limits 

 

to be all changes applied it is mandatory to 

save settings

. After setup of SSID and saving settings is symbol 

CL

 shown. 

 

BUTTONS CONTROL 

 

 

switching between client (CL) / access point mode (AP):

 

-

 

press button MODE for longer than 3 seconds and after that confirm by button SET 

 

 

showing current IP address of the WiFi sensor:

 

-

 

short press of the MODE button 

 

The  sensors  do  not  require  any  special  operation  and  maintenance.

  We  recommend  doing  regular  verification  of  the  accuracy 

of calibration measurements. 

 

SAFETY INSTRUCTIONS 

 

 

 

-   read the 

Safety Instructions

 for Wx7xx series sensors carefully before using and follow them during device operation 

 

-  the devices contain electronic parts and must be disposed of according to local and currently valid legal conditions 

 

-  to  complete  the  information  provided  in  this  manual,  use  the  detailed  manuals  and  other  documents  available 

in the 

“Download” section of the specific 

device a

www.cometsystem.com