- 4 -
BATTERY REPLACEMENT
If it is necessary to replace the batteries in the
Batteries holder directly at the installation site, first
unscrew the transducer from the holder posts (2
M4 screws) and move it to the right of the Batteries
holder. Temporarily attach the transducer with only
one screw to the right post of the Batteries holder
as shown. Do not let the transducer hang by the
power cord. Remove the four screws at the corners
of case the Batteries holder and remove the cover.
Replace the batteries with new ones and
reassemble all the assembly in reverse.
TECHNICAL PARAMETERS
recommended batteries: Tadiran SL2770/S, lithium, 3.6 V, size "C"
output voltage:
3.6 V DC
continuous output current: max. 200 mA
short circuit protection of output: no
(recommended batteries are not dangerous in the event of a short circuit)
power output:
connection adapter for transducers Wx8xx
working position:
vertically, cable gland down
IP class:
IP65 (after mounting the connection adapter to the Wx8xx sensor)
operating temperature: -30 to +60 °C
weight without batteries: 200 g (including connection adapter)
maximum dimensions:
120 x 93 x 43 mm
DEVICE DIMENSIONS