Appendix A - Options
Flange DIN 45962 connection
The minimum thickness flange has to be 15 mm.
CAUTION
The rotation range shall be completely covered adjusting
the position of eSDB and fixing the locknut.
Figure 4
Figure 5
Fault monitoring
The device has a self-monitoring function to detect inter-
nal faults, which are displayed by
and failure contacts.
The following table lists the individual faults.
Fault
Indication
Error-relay
(Standard
configuration)
Error-relay
(Special
configuration)
Note
Failure of the
supply voltage
All
off
POWER FAILURE:
terminal 22-24-21
POWER FAILURE:
terminal 22-24-21
Check if the supply voltage is connected correctly
Electronic control
defective
Red - Fixed
POWER FAILURE:
terminal 22-24-21
POWER FAILURE:
terminal 22-24-21
Try to switch off and switch on the power supply. Reset the
device following instructions in Appendix C.
If the error remains, please contact us.
Heater 1
defective
Red - Fixed
SYSTEM FAILURE:
terminal 12-14-11
POWER FAILURE:
terminal 22-24-21
Reset the device following instructions in Appendix C.
If the error remains, please contact us.
Heater 2
defective
Red - Blinking
SYSTEM FAILURE:
terminal 12-14-11
POWER FAILURE:
terminal 22-24-21
Reset the device following instructions in Appendix C.
If the error remains, the dehydrating breather continues to work
because the main tank is not damage. In this condition, the
device may work for a long time. Please contact us to replace it.
WEIGHING CELL
defect/out of
range
Red - Fixed
SYSTEM FAILURE:
terminal 12-14-11
POWER FAILURE:
terminal 22-24-21
Reset the device following instructions in Appendix C. If error
remains it means that the weighing cell is damaged. Control of
the weight is no longer available, but the device works because
of the sensors redundancy (Humidity sensor). If the error
remains, please contact us.
HUMIDITY
SENSOR
defect
Red - Blinking
SYSTEM FAILURE:
terminal 12-14-11
POWER FAILURE:
terminal 22-24-21
Reset the device following instructions in Appendix C. If error
remains it means that the Humidity sensor is damaged. Control
of the humidity is no longer possible, but the device works
because of the sensors redundancy (Weight cell – eSDB M/L)
or the backup time control (eSDB XS/S). If the error remains the
dehydrating breather should be replaced. Please contact us.
EV Fail
defect
Red - Fixed
SYSTEM FAILURE:
terminal 12-14-11
POWER FAILURE:
terminal 22-24-21
Reset the device following instructions in Appendix C. If error
remains it means that the solenoid valve is damaged, and the
dehydrating breather should be replaced. Please contact us.
Table 9
SELF-DEHYDRATING BREATHERS eSDB XS/S/M/L