background image

21

1

ON

2 3 4

6

5

ON

1 2 3 4 6

5

ON

1 2 3 4 6

5

ON

1 2 3 4 6

5

ON

1 2 3 4 6

5

ON

1 2 3 4 6

5

1

2

4

3

5

Programming

code

DIP ON

1

1

12

3.4

23

1,2,3,5

2

2

13

1,3,4

24

4.5

3

1.2

14

2,3,4

25

1,4,5

4

3

15

1,2,3,4

26

2,4,5

5

1.3

16

5

27

1,2,4,5

6

2.3

17

1.5

28

3,4,5

7

1,2,3

18

2.5

29

1,3,4,5

8

4

19

1,2,5

30

2,3,4,5

9

1.4

20

3.5

31

1,2,3,4,5

10

2.4

21

1,3,5

11

1,2,4

22

2,3,5

TAB. A

Address button modules

First startup or restarting

DIP 1-5:

 addressing call button module

 (see TAB. A) 

Addressing call button modules means that, in the event they are replaced, it is not necessary to reprogram the button 

addresses. All you need to do is assign the same address as before to the new module. 

When starting up the module (30 sec. approx.): 

 

f

the button backlighting comes on

 

f

the red LED flashes

 

» At the end of the startup process the red LED switches off and the backlighting behaves according to its configuration.

To perform programming correctly, proceed as follows:

  I.

 

Address the button modules (see 

“Address button modules”

)

 II. 

Configure the ViP address for the UT8010 module via ViP Manager (see

“Programming via ViP Manager”

)

III. 

Program the ViP call addresses via ViP Manager (see

“Programming via ViP Manager”

)

Содержание UT8010

Страница 1: ...Passion Technology Design EN TECHNICAL MANUAL Ultra audio module IP ViP system Art UT8010...

Страница 2: ...power cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using Comeli...

Страница 3: ...separate power supply and non POE switch 16 Variant for using the external entrance panel relay 17 Variant with safety door lock 17 Module connection 18 Outdoor entrance panel module consumption tabl...

Страница 4: ...programming Facility for 2 call buttons To be finished with cap single button or dual button made using aluminium or professional grade plastic treated to prevent yellowing and dulling Adjustment and...

Страница 5: ...ction RTE programmable input RTE local lock release input DO door open indication Activate output Priority call or Call user GND SE RTE and door lock input reference negative SE electric door lock con...

Страница 6: ...ype Buttons Type of buttons Mechanical Number of buttons no 2 Backlighting colour White Off Terminals TX TX RX RX V V RTE GND SE SE COM NC NO Removable terminals Yes Number of inputs no 1 Number of ou...

Страница 7: ...3110 1 3110 1A 3110 2 3110 2A 3110 3 3110 3A 3110 4 3110 4A Rain shield UT9181 UT9182 UT9184H UT9183 UT9186 UT9189 UT9184 UT9188 Module holder finishing frame UT9161 UT9162 UT9163 UT9164 Optional The...

Страница 8: ...e mounted housing with frame Rain shield UT9191 UT9192 UT9194H UT9193 UT9196 UT9199 UT9194 UT9198 Housing frame UT9171 UT9172 UT9174H UT9173 UT9176 UT9179 UT9174 UT9178 Optional Surface mounted instal...

Страница 9: ...9 2 1 2 5 3 4 165 cm 130 cm 1 Flush mounted installation Optional BLACK Optional RED...

Страница 10: ...PDF to print the entrance panel name cards using the pre cut sheets C available in our catalogue Art UT9110 Custom engraved Full Metal Ultra nameplates are available on request Find out how https pro...

Страница 11: ...11 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...

Страница 12: ...12 165 cm 130 cm 2 5 3 4 UP 1 2 3 1 Wall mounted installation Optional BLACK RED Optional...

Страница 13: ...PDF to print the entrance panel name cards using the pre cut sheets C available in our catalogue Art UT9110 Custom engraved Full Metal Ultra nameplates are available on request Find out how https pro...

Страница 14: ...14 Installation with side by side boxes...

Страница 15: ...X UT8010 UT9200 MAX 10 ORANGE BLUE WHITE BLUE BROWN WHITE BROWN WHITE ORANGE GREEN WHITE GREEN TX GND SE SE NO NC C O M R T E V V TX TX RXRX UT8010 UT9200 POE STANDARD SWITCH Connections Connection wi...

Страница 16: ...00 MAX 15 120 240 V 1596B NC C O M V V TX TX RXRX UT8010 UT9200 MAX 30 N L ORANGE WHITE ORANGE GREEN WHITE GREEN TX 120 230 V 1595 GND SE SE NO NC C O M R T E V V TX TX RXRX UT8010 UT9200 NON POE ETHE...

Страница 17: ...NC C O M R T E V V TX TX RXRX UT8010 UT9200 4A MAX AC DC 12V 24V GND SE SE NO NC C O M R T E V V TX TX RXRX UT8010 UT9200 12 24V AC DC Variant for using the external entrance panel relay Variant with...

Страница 18: ...15 Outdoor entrance panel module consumption table Code Absorption W UT9200 Call button modules 0 5 UT9240 Information module 0 5 UT9240M Metal information module 0 5 UT9279M Number keypad module 4 5...

Страница 19: ...WHITE BLUE BROWN WHITE BROWN WHITE ORANGE GREEN WHITE GREEN TX 1440 L N V V 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN OUT GND SE SE NO NC C O M R T E V V TX TX RXRX UT9270 UT8010 Connection of button modules...

Страница 20: ...V V TX TX RXRX UT8010 UT8010 ORANGE BLUE WHITE BLUE BROWN WHITE BROWN WHITE ORANGE GREEN WHITE GREEN TX 1440 L N V V 1441 OUT 4 3 OUT OUT 2 1 IN 2 1 IN OUT GND SE SE NO NC C O M R T E V V TX TX RXRX U...

Страница 21: ...tton modules means that in the event they are replaced it is not necessary to reprogram the button addresses All you need to do is assign the same address as before to the new module When starting up...

Страница 22: ...was completed successfully you will hear a confirmation tone the red LED flashes and the button backlighting comes on if there is a device error you will hear an error tone 2 Press a button repeatedl...

Страница 23: ...ds you will hear a second beep 2 Release the reset button if the procedure was completed successfully you will hear a confirmation tone the red LED flashes and the button backlighting comes on for the...

Страница 24: ...o comelitgroup com For example programming call addresses for the buttons activating audiovisual indications adjusting the backlighting and twilight sensor threshold adjusting volumes speaker micropho...

Страница 25: ...1st edition 05 2021 code 2G40002707 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: