15
UP
L
L
UP
L
L
V+
V-
J4
Module connection
On systems with Art. UT2010 and power supply unit Art. 1210/1210A, the maximum current available for the
outdoor entrance panel modules is 100 mA.
Calculate the total power consumption of the modules in your system configuration using the Consumption
table.
If the total power consumption exceeds 100 mA, connect a supplementary power supply unit (Art. 1595)
to the V+ and V- contacts of the outdoor entrance panel, as shown in the figure below (see
connections with separate power supply”
). In any case, the total absorption must be lower than 500 mA.
Outdoor entrance panel module consumption table
Code
Consumption (mA)
UT9200
Call button modules
12.5
UT9240
Information module
12.5
UT9240M
Metal information module
12.5
UT9279M
Number keypad module
40
Relays disabled and audio or audio/
video module SE output used
75
With 1 bistable relay active
100
With 2 bistable relays active at the same
time
UT9310M
Magnetic induction module
245
Always needs to be powered by
additional power supply unit Art. 1595
UT9270
Touchscreen module
100
In systems with an outdoor entrance
panel consisting of 1 audio or audio/
video module, Touch module art.
UT9270 and up to 80 users, it is not
necessary to provide any additional
power supply.
For all other combinations, provide an
additional power supply unit art. 1595
powered by Art. 1210/1210A
A
B
powered by additional power supply unit Art. 1595
Содержание Simplebus2 Ultra UT2010
Страница 1: ...Passion Technology Design EN Simplebus2 Ultra audio module Art UT2010 TECHNICAL MANUAL...
Страница 8: ...8 2 1 2 UP 5 3 4 165 cm 130 cm 1 Flush mounted installation BLACK RED Optional Optional...
Страница 10: ...10 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...
Страница 11: ...11 165 cm 130 cm 2 UP 5 3 4 UP 1 2 3 1 Wall mounted installation Optional BLACK RED Optional...
Страница 13: ...13 Installation with side by side boxes...