background image

Passion.Technology.Design.

EN

TECHNICAL 

MANUAL

Audio/video module for Simplebus1 Ultra 

Art. UT1020

Simplebus1 Ultra remote camera audio module 

Art. UT1010VC

Содержание Simplebus1 UT1010VC

Страница 1: ...Passion Technology Design EN TECHNICAL MANUAL Audio video module for Simplebus1 Ultra Art UT1020 Simplebus1 Ultra remote camera audio module Art UT1010VC...

Страница 2: ...wer cables 230V or higher Safe usage To ensure Comelit products are used safely carefully observe the indications provided in the Manuals Instruction sheets make sure the system created using Comelit...

Страница 3: ...modules Art UT9200 18 Connection of Touch screen module Art UT9270 18 Connection of numeric keypad module Art UT9279M 19 Programming 20 Configure button type single dual 20 Address button modules 20...

Страница 4: ...tomatic nameplate backlighting switch off during daylight hours Omnidirectional digital microphone and double loudspeaker for high fidelity audio Audio visual indications for disabled individuals assi...

Страница 5: ...rmation button 12 Digital microphone Use screwdriver supplied 13 Terminal block for connection RTE programmable RTE local lock release input or DO input door open indication GND RTE or DO input refere...

Страница 6: ...cm 175 cm 120 Installation notes Art UT1020 The camera must not be installed in front of light sources or in places where the filmed subject is against the light In dim environments we recommend addi...

Страница 7: ...supply Power supply voltage 33 VDC Absorption in standby W 1 5 Maximum absorption W 6 HARDWARE CHARACTERISTICS Call type Buttons Type of buttons Mechanical Number of buttons no 2 Backlighting colour W...

Страница 8: ...HARDWARE CHARACTERISTICS Call type Buttons Type of buttons Mechanical Number of buttons no 2 Backlighting colour White Off Terminals L L V V COM NC NO SE GND RTE TX TX RX RX Number of inputs no 1 Numb...

Страница 9: ...dule holder finishing frame UT9161 UT9162 UT9163 UT9164 A Rain shield B Surface mounted housing with frame Rain shield UT9191 UT9192 UT9193 UT9196 UT9199 UT9194 UT9198 Housing frame UT9171 UT9172 UT91...

Страница 10: ...10 2 1 2 UP 5 3 4 165 cm 130 cm 1 Flush mounted installation Optional BLACK Optional RED...

Страница 11: ...module 2B CLOSE The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness of the nameplate adhesive label must not exceed 0 2 mm You can...

Страница 12: ...12 Installation with side by side boxes Before installing the boxes in the wall fit the spacers...

Страница 13: ...13 165 cm 130 cm 2 UP 5 3 4 UP 1 2 3 1 Wall mounted installation Optional BLACK RED Optional...

Страница 14: ...module 2B The button has a nameplate which can be written on A alternatively an adhesive label can be applied B The total thickness of the nameplate adhesive label must not exceed 0 2 mm You can visit...

Страница 15: ...15 Installation with side by side boxes...

Страница 16: ...GND SE NO NC C O M L L V V 230 V 10A MAX AC DC 12V 24V 120 230 V 1595 4888C Connections Connections for UT1020 UT1010VC Max 20 m Local door opener button C NC NO relay activation on actuator command 2...

Страница 17: ...17 4888C UP RED BLACK V S E T R GND SE NO NC C O M L L V V 120 230 V 1595 S V S V RED BLACK UT1010VC Remote camera connection Art UT1010VC only Max 20 m Local door opener button...

Страница 18: ...L L V V 120 230 V 1595 4888C UT1020 UT1010VC E T R GND SE NO NC C O M L L V V 120 230 V 1595 UT9270 Module connection Connection of button modules Art UT9200 Connection of Touch screen module Art UT92...

Страница 19: ...19 4888C UT1020 UT1010VC E T R GND SE NO NC C O M L L V V 120 230 V 1595 UT9279M Connection of numeric keypad module Art UT9279M Max 20 m Local door opener button...

Страница 20: ...1 1 2 4 22 2 3 5 TAB A Configure button type single dual DIP 6 configuring button type Single button DIP6 ON Dual button DIP6 OFF default I Address button modules DIP 1 5 addressing call button module...

Страница 21: ...is complete make sure the button configuration is correct single dual see Configure button type single dual Take note of the DIP switch settings example code 1 Set the address of the apartment you wi...

Страница 22: ...lete make sure the button configuration is correct single dual see Configure button type single dual Take note of the DIP switch settings example code 25 example code 37 example code 70 example code 5...

Страница 23: ...tch settings 1 Set the dip switches in accordance with the function you wish to program see table 2 Press the confirm button Reset the configuration of the DIP switches When programming is complete ma...

Страница 24: ...C NC NO relay activation on actuator command 8 sec Door lock 223 1 2 3 4 5 7 8 Door lock command on SE in AC default 224 6 7 8 Door lock command on SE in enhanced AC 225 1 6 7 8 Door lock command on S...

Страница 25: ...8 Light me OFF default 163 1 2 6 8 Light me ON the button LEDs for the audio video module are always on and when the button is pressed all button LEDs light up see Light me function behaviour on the...

Страница 26: ...In AUTO mode the twilight sensor checks the ambient light level every 9 minutes if the measured values exceed the specified minimum maximum thresholds it is activated deactivated accordingly When pro...

Страница 27: ...If it is daytime and you want to check AUTO mode operation for the twilight sensor you can proceed as follows 1 Enter programming mode 2 Block the twilight sensor for 5 seconds If AUTO mode has been s...

Страница 28: ...DIP switch settings Enable brightness control A for the camera code 171 or B for the buttons code 161 Set the desired function code 171 161 and press the confirm programming button Press a button repe...

Страница 29: ...ight me function behaviour on the basis of the LED backlighting mode Thanks to this function button backlighting is only enabled on the user s request by pressing the LIGHT ME button on the audio vide...

Страница 30: ...mming mode by moving S2 DIP switch upwards the red system busy LED flashes for the duration of the procedure 2 Set special programming 114 to import all the programming settings 3 Press the confirm pr...

Страница 31: ...ble to download free of charge from pro comelitgroup com You will need a USB micro USB cable Errors and indications INDICATION SOLUTION RED LED LIT STEADILY DISSUASION TONE Line short circuit Check co...

Страница 32: ...2 7 8 224 6 7 8 15 1 2 3 4 45 1 3 4 6 75 1 2 4 7 105 1 4 6 7 135 1 2 3 8 165 1 3 6 8 195 1 2 7 8 225 1 6 7 8 16 5 46 2 3 4 6 76 3 4 7 106 2 4 6 7 136 4 8 166 2 3 6 8 196 3 7 8 226 2 6 7 8 17 1 5 47 1...

Страница 33: ...1st edition 09 2020 code 2G40002537 w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: