Wiring diagram

Instruction
•  Sensitivity level setting: 

0~7 level can be set, the higher the level, the lower the sensitivity. 

the setting level is equal to the sum of the corresponding numbers of the jumper caps that are 

shorted. For example: 1 and 4 jumper caps are shorted, 1+4=5, then the level is 5. When all 

jumpers are not inserted, it is level 0. Level 0 and Level 1 do not detect piezoelectric vibration 

sensor, only detect mechanical vibration sensor.

•  Tamper port:

 Normally closed by default when the cover is installed, and disconnected when 

the cover is opened.

•  Relay output port:

 Normally closed by default when power on, and disconnected when alarm.

•  Power input terminal:

 DC 9~24V power supply.

LED working status

•  It enters the self-checking status when it is turned on, the green light fl ashes for 20 seconds
•  Under normal working conditions, the green light is on
•  Under alarm conditions, the red light is on
Note: During the power-on self-test, do not have vibration interference in abnormal use environment.

Disassembly and assembly installation

1.  Remove the cover, insert a screwdriver into the gap beside the screw cover, gently pry up the 

screw cover, loosen the screws, and then separate the cover and bottom base.

2.  Wiring: DC9~24V power supply; TAMPER-tamper ; ALARM-signal line. 
3.  Remove the bottom base of the detector and fi x it with screws to the position where the holes 

need to be installed, or fi x it with AB glue. The detection radius of the installation surface is as 

follows:

Installation surface

Concrete

Brick wall

Steel plate

Wood board

Glass

Detection radius

1.5m

2.5m

3m

3.5m

3.5m

Note: The above detection radius is for reference only, and it depends on the actual use environment.