4.9.2.4 Alarm group
In the navigation bar select
“SNMP>Rmon Config>Alarm Group”
, define alarm group.
As the following picture
【
Parameter Description
】
Parameter
Description
index
The index number for alarm list items, value range is 1 ~ 65535
Static table
Statistical type values :3:DropEvents; 4:Octets; 5:Pkts;
6:BroadcastPkts;
7:MulticastPkts;
8:CRCAlignErrors;
9:UndersizePkts; 10:OversizePkts; 11:Fragments; 12:Jabbers;
12:Collisions;
14:Pkts64Octets;
15:Pkts65to127Octets;
16:Pkts128to255Octets;
17:Pkts256to511Octets;
18:Pkts512to1023Octets; 19:Pkts1024to1518Octets
statistical index
Set up the corresponding statistics statistical index number,
decided to statistics to monitor the port number
Sampling interval
Sampling time interval, the scope for 5 ~ 65535, the unit for
seconds
The sampling type
Sample types for the absolute value of sampling, the sampling
time arrived directly extracting the value of a variable
The
latest
sampling
Sampling type for change value sampling, extraction of the
arrival of the sampling time is variable in the change of the
sampling interval value
The
alarm
threshold
upper
limit
Set the upper limit the parameter values
The
alarm
threshold
lower
limit
Set the lower limit parameter values