![Comelit HFX-700R KIT Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/comelit/hfx-700r-kit/hfx-700r-kit_installation-and-operation-manual_2640140012.webp)
10
STAGE 3:
Wiring and settings
PT1
PT2
DG1
DG2
OUT+
OUT-
DR2
DR1
POWER
<+>
<->
JP1
JP2
1
2
3
4
Main monitor
Wiring terminal
Red
Black
1
2
4
5
door camera
Wiring terminal
To expansion monitor
3
6
Terminals for magnetic switch (optional)
Terminals for external chime (optional)
Terminals for expansion monitor (w/polarity)
Terminals for the 2nd door camera (no polarity)
Terminals for the 1st door camera (no polarity)
Terminals for power adapter
Terminals to main monitor (no polarity)
Terminals for door strike
Electric Lock
1
2
3
4
5
6
7
8
9
7
8
External chime(optional)
To the 2nd door camera
Magnetic switch(optional)
9
A. Wire the system from door camera terminals to monitor terminals
accordingly.
B. Select and plug JP2 to its RIGHT( ) to disable LED illumination of the
doorbell camera when it's activated. Factory setting is LEFT( ) which
enables automatic LED illumination.
C. Select and plug JP1 to its RIGHT( ) for direct current output control
(12VDC 300mA) directly for a strike. Factory setting has JP1 to its LEFT
( ) for dry contact bridge control.(Refer to 3.3 Door Release Options)
D. External chime wiring diagram refer to figure 1.
DG1
DG2
Figure 1: External chime wiring diagram (DC or AC power supply)
POWER
External chime
NOTE: External chime(DG1,DG2) provide as a normal open dry contact
with no polarity, allowing maximum by-pass current of AC24V or
DC24V 1A.
AC24V or
DC24V 1A