Comelit 4893M Скачать руководство пользователя страница 7

7

DIP-SWITCH

FUNCTION

DIP 1

The lock-release relay and the second relay are controlled by 2 separate buttons (e.g. lock-

release button and actuator button) 

 *

The lock-release relay and the second relay are controlled by a single button (e.g. lock-release 

button) 

DIP 2

lock-release activation time: 8 sec

 *

lock-release activation time: 2 sec

DIP 3

relay activation time: 8 sec

 *

relay activation time: 2 sec 

DIP 4

reset wait time: 1 sec

 *

reset wait time: 10 sec

DIP 5

Call transmission: triple

 *

Call transmission: single

DIP 6

confirmation tones (call, lock-release, relay, audio enabled): disabled

 *

confirmation tones (call, lock-release, relay, audio enabled): enabled 

DIP 7

Camera lighting LED: disabled

 *

Camera lighting LED: enabled

DIP 8

LED lighting of name-holder front panels: OFF

 *

LED lighting of name-holder front panels: ON

* default

Settings

Set the DIP-switches of S1 corresponding to the function that you want to programme as shown in the table below.

Содержание 4893M

Страница 1: ...Passion Technology Design EN TECHNICAL MANUAL Quadra audio video entrance panel Art 4893M...

Страница 2: ...ion sheets supplied with those products Wires Cut off the power supply before carrying out any maintenance procedures Use wires with a cross section suited to the distances involved observing the inst...

Страница 3: ...programming confirmation switch 11 Loudspeaker volume control 12 Audio balance 13 Terminal block M2 SE SE connection for electric door lock NCrelay normally closed contact NOrelay normally open contac...

Страница 4: ...250 Clamps LL RTE COM DO SE SE C NC NO Buttons to call Yes Total buttons 4 Microphone volume control Yes Loudspeaker volume control Yes Operating temperature C 25 55 IP protection rating IP54 Vandal...

Страница 5: ...m environments we recommend additional lighting is provided 4 2 3 1 163 cm 130 cm COM L LRTE 4 5 1 3 J O H N D O E 2 1 2 1 2 3 4 1 Settings Microphone Loudspeaker 6 1 2 1 2 1 2 3 You can download the...

Страница 6: ...t make sure that the fixing procedure is carried out correctly Before securing the screw make sure that you do not need to program the external unit and make sure that the metal front panel does not r...

Страница 7: ...ec relay activation time 2 sec DIP 4 reset wait time 1 sec reset wait time 10 sec DIP 5 Call transmission triple Call transmission single DIP 6 confirmation tones call lock release relay audio enabled...

Страница 8: ...ce art 1404 default condition 16 5 Secondary Quadra with digital switching device art 1405 32 6 Main Quadra with digital switching device art 1405 254 2 3 4 5 6 7 8 Restore default Programming Call ad...

Страница 9: ...al units activating alternately the main external unit and the secondary external unit For the diagrams please refer to the Audio Video kit system section in the system manual Operation with additiona...

Страница 10: ...a generic call address Take note of the DIP switch settings Enter programming mode Set the user code using the DIP switches in accordance with the addressing table 1 3 2 4 Reset the configuration of t...

Страница 11: ...nter programming mode Set the DIP switches to position 206 ON 2 3 4 7 8 in accordance with the addressing table 1 Reset the configuration of the DIP switches Disabling the COM RTE contact 3 2 4 To re...

Страница 12: ...use variant Variant for using a safety door lock and additional power supply Using the RC network for door lock filter on relay contacts On NO C contacts On NC C contacts Excluded clean contact JP1 J...

Страница 13: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 1 ed Rev 1 10 2018 cod 2G40002095 C E R T I F I E D M A N A G E M E N T S Y S T E M S...