A new parameter is entered by scrolling through the possible values using the number keys.
 

1. 

Press the number corresponding to the desired value (in the example 0 = Italian).

 

» after 2 sec. the parameter corresponding to the entered number appears on screen.

 

2. 

Press 

 to confirm the parameter. 

 

f

Press another number to change your selection.

 

f

Press   to return to the menu level above.

EXAMPLE: “italiano” selected as language

LANGUAGE   

DEFAULT

LANGUAGE

_ _ _ 0

LANGUAGE

ITALIANO

PARAMETER

CHANGED

0

2 sec

Self-testing

Call mode testing

When the device is switched on, it performs a test to check the type of system configured on the speaker (Simplebus, 

Simplebus Top or VIP).

If the digital call module is new (or if the parameters have been restored to the default values):

•  if the module is connected to a VIP system

 

» the module aligns with the speaker, self-configuring in “VIP call mode”, and receives all the information and data stored 

on the speaker;

•  if the module is connected to an SB TOP system

 

» he first call mode display screen shows the string ERROR  .

•  if the module is connected to an SB system

 

» the first call mode display screen shows the string SIMPLEBUS.

If the digital call module has a directory already containing data:

•  if the directory and speaker are configured differently:

 

» he first call mode display screen shows the string ERROR  .

•  if the directory and speaker are aligned:

 

» the first checking screen will show the system type SB / SB TOP / VIP.

   Follow the procedure described in “1.1.3. CALL MODE” if you want to align the directory module with the type of 

system configured on the speaker.

INITIAL CONDITION

Module powered up

CALL MODE

PLEASE WAIT

The message PLEASE WAIT indicates self-

testing in progress.

CALL MODE

SIMPLEBUS

At the end of self-testing the type of system 

set is displayed (SIMPLEBUS by default).

or:

CALL MODE

ERROR

If the directory and speaker are configured 

differently. 

   Follow the procedure described in “1.1.3. CALL MODE” if you want to align the directory module with the type of 

system configured on the speaker.

Содержание 3070S

Страница 1: ...EN TECHNICAL MANUAL Digital call module Art 3070S Passion Technology Design...

Страница 2: ...vities connected to the installation of Comelit products must be carried out by qualified technical personnel with careful observation of the indications provided in the Manuals Instruction sheets sup...

Страница 3: ...an electronic key code device with a possible 1000 different 6 digit codes For use in Building kit SBTOP SB1 audio SB2 audio and ViP systems 1 2 MR1 MR2 1 LCD screen 2 Alphanumeric keys Terminal block...

Страница 4: ...ONS No user codes 1000 FUNCTIONS Key button function Yes HARDWARE SPECIFICATIONS Total buttons 12 COMPATIBILITY Simplebus Top audio video system Yes Building Kit audio video system Yes Simplebus 2 aud...

Страница 5: ...m It is possible to use up to 5 terminals Art 3070S 3072S Maximum distance between l Art 20022618 and furthest terminal Art 3070S 3072S 100m 1195 0 2 3 0 2 4 1 2 0 120E 1 4W D D X T R X R P 12 12 3070...

Страница 6: ...O D E T R SE SE NC O V V G N D NO 1595 Local lock release button Use the cable 2E7T000696 supplied with Art 3070S and Art 3072S 3070S X T R X R P D S S YELLOW V BLUE S D 3072S 12 12 P R X R T X 12 12...

Страница 7: ...232 line or over an RS485 line by means of the interface card Art 20022618 see Connection to computer Reading Upload the list of users stored on the directory module via connection to PC equipped with...

Страница 8: ...data stored on the speaker if the module is connected to an SB TOP system he first call mode display screen shows the string ERROR if the module is connected to an SB system the first call mode displ...

Страница 9: ...o DEFAULT you will be asked to set the language again at the next startup Press the key to confirm the value of the parameter Press to exit the selected language PARAMETER CHANGED If entry is successf...

Страница 10: ...URE DISPLAY INFO DESCRIPTION Press the key PASSWORD _ _ _ _ _ _ CONFIRM WITH To cancel the procedure press the key Enter the password code min 4 characters PASSWORD _ _ CONFIRM WITH If the password is...

Страница 11: ...s exited programming mode Or PROCEDURE DISPLAY INFO DISPLAY INFO In standby Press PASSWORD _ _ _ _ _ _ CONFIRM WITH Login screen Enter the supercode default 778899 PASSWORD CONFIRM WITH If the superco...

Страница 12: ...ng the conversation time The minimum not current value of the parameter appears on screen To change the parameter enter a new value ENTER t AUDIO _ _ 20 Choose a value that falls within the following...

Страница 13: ...igured value appears on screen Select the download type by entering the corresponding number 0 RS232 1 RS485 DOWNLOAD TYPE _ _ _ 1 DOWNLOAD TYPE RS485 2 sec EXAMPLE Changing the download type Press th...

Страница 14: ...rt Code field a zone field with up to 3 digits between 1 and 500 and a user field which must have 3 digits between 1 and 240 The call is made as follows 1 On the keypad enter the code 25 015 2 press t...

Страница 15: ...he key to confirm the value of the parameter PLEASE WAIT If the change was successful the speaker will emit a confirmation tone CALL MODE STANDARD The current value of the parameter appears on screen...

Страница 16: ...s parameter is used to set the language in which messages are displayed PROCEDURE DISPLAY INFO DESCRIPTION Access configuration see Accessing exiting the configuration stage Select the menu SETTINGS L...

Страница 17: ...f directory entries 0 Number of password entries 0 This procedure resets the directory and password database PROCEDURE DISPLAY INFO DESCRIPTION Access configuration see Accessing exiting the configura...

Страница 18: ...the parameter PARAMETER CHANGED If entry is successful or PASSWORD ALREADY IN MEMORY If the password has already been entered Exit configuration see Accessing exiting the configuration stage PROCEDURE...

Страница 19: ...to confirm the value of the parameter To exit the menu press PARAMETER CHANGED If entry is successful Up to 1000 password codes can be entered or PASSWORD ALREADY IN MEMORY If the password has alread...

Страница 20: ...LEASE WAIT PARAMETER CHANGED Exit configuration see Accessing exiting the configuration stage 3 Info This procedure can be used to view the firmware version the number of users stored NO VIP the numbe...

Страница 21: ...Indirect Code entries in software Art 1249B or load an existing list ENTER USER CODE Press the Download button in software Art 1249B DOWNLOADING COMPLETED If the download was completed successfully Or...

Страница 22: ..._ _ _ 0 INDIRECT CODE NO VIP NO VIP STANDARD _ _ _ 1 _ _ _ 0 INDIRECT CODE NO VIP NO VIP CALL MODE ADDRESS RS485 _ 250 RANGE SB SBTOP 0 255 NO VIP LANGUAGE DEFAULT SETTINGS SUPERCODICE LANGUAGE _ _ _...

Страница 23: ...requirements Building Kit audio video system for the creation of audio video systems for small apartment blocks SBTOP audio video system for the creation of audio video systems for residential comple...

Страница 24: ...w w w c o m e l i t g r o u p c o m Via Don Arrigoni 5 24020 Rovetta BG Italy 1 edizione 07 2018 cod 2G40002105 C E R T I F I E D M A N A G E M E N T S Y S T E M S...

Отзывы: