Program Levels
9
Programming (Levels L2 and L3)
♦
Enter from Basic level
by pressing and holding
.
♦
To access and adjust the parameters
from level L2, release the key
while
PAr
is displayed.
To enter level L3, release the key
when
conF
appears on the display.
♦
Choose a parameter using
or
.
♦
To enter parameter value adjustment
mode, press
.
♦
If no key has been pressed
for a while, the device automatically
returns to Basic level, storing all
confirmed changes.
♦
For quick exiting and saving,
use key combination
+
.
Output Control
Alarm output operation
♦
The alarm outputs operate according
to the control algorithm parameters.
♦
The outputs deactivate
with the value change
of one of the following configuration
parameters -
Point Position
,
Input Low
,
Input High
, and
Input Correction
-
and remain inactive till Basic level
is entered.
♦
The outputs deactivate also
when an error has been detected
(see
'
Error messaging
')
and remain inactive until all
discrepancies are resolved
and programming exited.
♦
An input failure
deactivates the outputs too.