Installing The SCbus Interface Board

In The Impact FXS Digital Communications System

Introducing The SCbus Interface Board

The SCbus interface board allows Computer Telephony (CT) applications to connect one or more SCbus
compatible circuit boards in the Impact FXS computer (for example; network, voice, fascimile, speech
recognition, video, and so forth) to the Impact FXS’ digital station or trunk ports through time division
multiplexing (TDM) on the SCbus.

SCbus is a TDM bus for communications within a node of the Signal Computing System Architecture (SCSA).
(The SCSA standard specifies the signal processing system for PC-based voice and call processing, and telecom
switching.)  The SCbus features an architecture that includes a serial message path for signaling and control and a
16-wire parallel Time Division Multiplexing (TDM) data path.

The conversion of a CTI application from traditional loop start ports to digital SCbus ports provides a more
effective and efficient operation than that provided by analog ports, which historically have been used in the CTI
industry.

CTI applications use the Enterprise or wideopen.office

toolkit in order to perform switching operations and call

processing on the Impact FXS SCbus interface board that is plugged into the Impact FXS proprietary telecom
backplane. These toolkits consist of PC software libraries that provide the instructions to the FX system for
performing these functions.

When installing more than one SCbus interface board, install the first one in the 6th (top) universal board slot of
the Impact FXS telephony portion and the next one in the 5th universal board slot, and so forth. Connect the
SCbus interface board’s ribbon cable to the CTI application board that is plugged onto the Impact FXS
computer’s motherboard. The internal cable connection between the SCbus board and the CTI application board
routes the voice-path between the two locations. Attach the PC power cable from the power supply to the SCbus
interface board to the first SCbus interface board you installed. Any subsequent SCbus interface boards you install
do not require the power connection. In addition to these internal cables, the installation requires external cabling
between the Impact FXS system’s computer and telephony portion. The particular external cabling required is
dependent upon the CTI application being operated. For example, when using a voice mail application, a cable is
required to connect the computer’s COM 2 port to the telephony’s COM 2 port. The cabling requirements are
illustrated in the figure on page 7 of this instruction.

An SCbus installation includes the following items:

SCbus Interface Board (product code FXSCBUS)

SCbus Application Board or Boards (as needed)

Enterprise ToolKit Software including all required disks (product code ENTRP-SW)

wideopen.office

is a registered trademark of Comdial Corporation, Charlottesville, VA

R

This manual has been developed by Comdial Corporation (the “Company”) and is intended for the use of its customers and service personnel. The information in this manual is subject to change without notice.
While every effort has been made to eliminate errors, the Company disclaims liability for any difficulties arising from the interpretation of the information contained herein.
The information contained herein does not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation, or
maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, contact Comdial,  Inside Sales Department,
Charlottesville, Virginia 22906.

Printed in U.S.A.

IMI89–313.01

2/99

Содержание SCbus

Страница 1: ... s motherboard The internal cable connection between the SCbus board and the CTI application board routes the voice path between the two locations Attach the PC power cable from the power supply to the SCbus interface board to the first SCbus interface board you installed Any subsequent SCbus interface boards you install do not require the power connection In addition to these internal cables the ...

Страница 2: ...nd and three SCbus interface boards in the Impact FXS telephony portion Considering Related Publications Installing The Impact FXS Common Equipment Cabinet Comdial pub number IMI66 134 The SCSA Hardware Model Specification Version 3 0 11 94 Dialogic pub number 05 0104 007 Dialogic Corporation Parsippy NJ 07054 Complying With Underwriters Laboratories Regulations Per The Underwriters Laboratories r...

Страница 3: ... a circuit board has a pre charge port on its front panel disconnect the AC power cord from the AC service outlet and disconnect the cable between the cabinet and any external battery back up assembly before you remove or install the circuit board However if the board does include a pre charge port you can connect a standard telephone handset cord between the pre charge port on the circuit board a...

Страница 4: ... board slot Most line station and special purpose interface boards use the universal slots When installing the first SCbus board use the 6th top universal slot to insure a proper connection to the PC power cable Any subsequent SCbus boards installed do not require the PC power connection 5 If you are removing or installing the board in an operating system connect the free end of the precharge cord...

Страница 5: ...Removing And Installing Circuit Boards 5 Installing The SCbus Interface Board IMI89 313 screws2 cdr Locating The Board Retaining Hardware remove cdr Removing And Installing Circuit Boards ...

Страница 6: ...stalling The SCbus Interface Board PC Power Connector Transmit Slip LED Receive Slip LED Loss Of Clock Synch Alarm LED SCbus Ribbon Cable Connector Backplane Connector SCbus Ribbon Cable Elastic Buffers optional for SCbus Clock Slave Config uration To PC Board Connector Precharge Jack Status LED Board Reset Button Detailing The SCbus Interface Board CTI Application Board SCbus Interface Board PC P...

Страница 7: ...installation to determine that the board is synchronized with Impact FXS CPU board Once installed the system creates 32 additional station ports that correspond with the 32 telecom ports on the SCbus interface board Future software and hardware revisions will enable installers to program these telecom ports to be either station or line boards Installing The SCbus Interface Board IMI89 313 Connecti...

Страница 8: ...dware considerations You must install a T1 Sync card on the Impact FXS AUX board reset the Impact FXS system after installing the Sync card to cause the system to recognize it You must configure one of the SCbus interface boards as a clock master Install the two elastic buffer ICs on each SCbus interface board NOTE Currently if you have a requirement for this clock configuration you must obtain fr...

Страница 9: ...lled the Dialogic system software in C DLGCDEV CAUTION You must run the FXTSREQ EXE utility before you start the Dialogic service Refer to the Dialogic documentation for start and stop details The Dialogic system software calls the FXTSMAP EXE utility software when it needs to do so Never run FXTSMAP EXE manually It s the Dialogic system software s responsibility to call FXTSMAP EXE with the prope...

Страница 10: ...IMI89 313 Installing The SCbus Interface Board Charlottesville Virginia 22901 2829 R World Wide Web http www comdial com ...

Отзывы: