Maintenance
Abrasive Containment and Disposal
Empty the abrasive hopper by placing a pail
or plastic bag under either of the hopper
outlets and open the valve.
Empty the container and repeat as needed.
Warning: Excessive abrasive in the hopper may
cause powder to leak through vent holes.
Filter Cleaners
Filter cleaning mallets are located on both
sides of the ProCenter Plus. Before each
shift, with the power turned off, pull and
release the mallets two or three times.
This action will dislodge spent media that
may have collected in the HEPA filter.
Changing the HEPA Filter
Remove any equipment sitting
on top of the filter box.
Disconnect the power cords
on both sides of the filter box.
Remove filter box cover.
Remove and replace filter.
(CTR280‐1 Replacement HEPA
filter assembly)
Air Dryer Maintenance
The desiccant inside the air dryer bowl will gradually turn from bright
orange to dark green as it becomes saturated. Change according to
the instructions included with the
air dryer.
For maintenance instructions on your
air dryer, please see manual “AD5100
Series – Desiccant Air Dryer.”
NEED HELP?
Comco Tech Support: 818‐841‐5500
www.comcoinc.com
8/2021
TS414