background image

ProCenter Plus

Manual

Maintenance

Abrasive Containment and Disposal

Empty the abrasive hopper by placing a pail 
or plastic bag under either of the hopper 
outlets and open the valve.
Empty the container and repeat as needed.

Warning: Excessive abrasive in the hopper may 
cause powder to leak through vent holes.

Filter Cleaners

Filter cleaning mallets are located on both 
sides of the ProCenter Plus.  Before each 
shift, with the power turned off, pull and 
release the mallets two or three times.  
This action will dislodge spent media that 
may have collected in the HEPA filter.

Changing the HEPA Filter

Remove any equipment sitting 
on top of the filter box.  
Disconnect the power cords 
on both sides of the filter box.  
Remove filter box cover.  
Remove and replace filter. 

(CTR280‐1 Replacement HEPA 
filter assembly)

Air Dryer Maintenance

The desiccant inside the air dryer bowl will gradually turn from bright 
orange to dark green as it becomes saturated.  Change according to 
the instructions included with the 
air dryer.

For maintenance instructions on your 
air dryer, please see manual “AD5100 
Series – Desiccant Air Dryer.”

NEED HELP?

Comco Tech Support: 818‐841‐5500

[email protected]

www.comcoinc.com

8/2021

TS414

Отзывы: