7. Common Failure Analysis and Troubleshooting 

 

Failure phenomenon 

Failure cause 

Solution 

Power  on,  the  front 
panel  display  screen 
and power indicator are 
both off 

Switching power supply 
couldn't 

start; 

equipment;  internal  DC 
power  supply  is  not 
working. 

Check  if  the  power 
supply is normal (should 
be  AC:  110V-250V).  If 
the  supply  voltage  is 
normal,  it  could  be  a 
failure 

of 

switching 

power  supply  module. 
Please 

contact 

the 

dealer or our company. 

Power  on;  the  display 
screen  is  off,  only  the 
power indicator is on 

The 

internal 

microprocessor  is  not 
working. 

Please 

contact 

the 

dealer or our company. 

Power  on;  the  optical 
output power displayed 
on  the  front  panel 
display screen and laser 
status  indicator  are 
both  normal,  but  the 
actual measured optical 
output power is low 

1.  The  poor  quality  of 
the test jumper. 
 2.  The  active  fiber 
connector  or  adapter 
may be contaminated.  
3.  The  ceramic  tube  in 
the  adapter  may  have 
been broken 

1.  Replace  with  good 
quality test jumper. 
 2. 

Clean 

the 

contaminated 

active 

fiber 

connector 

or 

adapter. 

Specific 

operation  methods  see 

“The 

clean 

and 

maintenance method of 
optical 

fiber 

connector”.

 

 3. 

Replace 

the 

damaged adapter. 

After initial startup, the 
image  of  the  optical 
contact 

point 

has 

obvious netlike curve or 
large 

particles 

highlights. 

1.  The  received  optical 
power  of  the  optical 
contact  point  is  too 
high; the output level of 
the  optical  receiver 
module  is  too  high  and 
intermodulation  index 

 
 
1.  Check  the  received 
optical  power  of  the 
optical  contact  point 
and  make  appropriate 
adjustments.   

Содержание 1310nm TX

Страница 1: ...1310nm TX www comcast sa com 1310nm Transmitter ...

Страница 2: ...tical link carrier to noise ratio degradation table 8 5 External Function Description 9 5 1 Front Panel Description 9 5 2 Rear Panel Description 10 5 3 Displayed Parameter description 11 6 Installation debugging 15 6 1 Unpack and Check 15 6 2 Instruments and tools 15 6 3 Installation steps 15 7 Common Failure Analysis and Troubleshooting 17 The Clean and Maintenance Method of Optical Fiber Connect...

Страница 3: ...t operation or accident harm to the operator While the optical transmitter is working there is an invisible laser beam from the optical output adapter on the front panel Avoiding permanent harm to the body and eye the optical output should not aim at the human body and human should not look directly at the optical output with the naked eye Please make sure that the ground terminal of the case and ...

Страница 4: ...pectral lines good linearity and high output power The RF drive part adopts the RF power digital automatic processing technology Automatic processing the drive level power according to the RF input signal level and the number of channels 15 84 channels make the CSO CTB and C N index always at the optimal value to ensure the overall performance Advanced multi frequency RF pre distortion technology ...

Страница 5: ...1U standard rack mount equipped standard IEEE802 3 10Base T Ethernet interface and RS232 interface can expediently realize network management monitoring Fully support GB T 20030 2005 HFC Network device management system specification ...

Страница 6: ...tions and methods of measurement on AM optical transmitter and receiver used in CATV systems and tested under the specified test conditions Test condition With standard optical fiber and standard optical receiver composed the test link Set 84 PAL D analog TV channel signal at 750MHz frequency range under the specified link loss When the optical input power of optical receiver is 1dBm measure the C...

Страница 7: ...1310nm TX www comcast sa com 4 2 Technique Parameters Table ...

Страница 8: ...1310nm TX www comcast sa com 4 3 Optical link carrier to noise ratio degradation table ...

Страница 9: ...normal flashing red light means the machine has broken down related fault reason see the alarm menu of the display menu green light means the laser is working normal 4 RF status indicator Flashing red light means the RF input signal is warned green light means RF input signal is normal 5 160 32 dot matrix LCD screen used to display all the parameters of the machine 6 Display the exit or cancel key...

Страница 10: ...232 interface Console Used for configuring the network management parameters 3 LAN interface correspond with IEEE802 3 10Base T used for network management 4 Optical signal output This interface is the optical signal output port of the device The connector type is FC APC There is an invisible laser beam from this port while working normal So the port should not be aligned to human body or naked ey...

Страница 11: ...duct s Logo and model 2 Turn the key to the on position shows the turn on delay Delay countdown 3 After entering the system RF input signal level and optical output power at present 4 Press Enter key into the menu index 1 Parameter menu 2 Set parameters 3 Alarm menu 5 Sub menu of parameters Press Enter key into the menu ...

Страница 12: ...1310nm TX www comcast sa com ...

Страница 13: ...1310nm TX www comcast sa com ...

Страница 14: ...1310nm TX www comcast sa com 6 Setting menu Press Enter key into the menu ...

Страница 15: ...act local agency or our company in time 6 2 Instruments and tools 1 An optical power meter 2 A digital multimeter 3 A standard optical fiber test jumper FC APC or SC APC 4 Some absolute alcohol and medical cotton wool 6 3 Installation steps 1 Before installing the equipment please read the User s manual carefully and install the equipment according to the User s manual Note For the man made damage...

Страница 16: ...en press the menu button on the front panel to check the working parameters 5 Connect the optical power meter to the optical signal output end by the standard optical fiber test jumper then measure the optical output power Affirm the measured optical output power and the displayed power are the same and have reached the nominal value Affirm the optical power meter is on 1310nm wavelength test posi...

Страница 17: ...e front panel display screen and laser status indicator are both normal but the actual measured optical output power is low 1 The poor quality of the test jumper 2 The active fiber connector or adapter may be contaminated 3 The ceramic tube in the adapter may have been broken 1 Replace with good quality test jumper 2 Clean the contaminated active fiber connector or adapter Specific operation metho...

Страница 18: ...of the optical contact point has obvious noises 1 The received optical power of the optical contact point is not high enough results in decrease of C N 2 The RF signal level input of the optical transmitter is too low make modulation degree of the laser is not enough 3 The C N index of system link signal is too low 1 Recover received optical power of the optical contact point by cleaning the activ...

Страница 19: ...e RF connector shielding effect is not good 3 Close the equipment enclosure tightly to ensure the shielding effect if possible add shielding cover to the optical contact point and reliable grounding After initial startup at optical contact points the image of several channels have obvious noises The C N indexes of these channels are too low Check the C N of these channels signal and make appropria...

Страница 20: ...tor types do not match maybe the APC type connect to PC type make the optical signal cannot normal transmission The active fiber connector or adapter may be contaminated seriously or the adapter has been broken 1 1 Check the fiber connector type adopt the APC type fiber connector to ensure the normal transmission of optical signal 2 Clean the contaminated active fiber connector or adapter Specific...

Страница 21: ...1310nm TX www comcast sa com ...

Страница 22: ...bent alcohol cotton If use the medical absorbent alcohol cotton still need to wait 1 2 minutes after wash let the connector surface dry in the air 3 Cleaned optical connector should be connected to optical power meter to measure optical output power to affirm whether it has been cleaned up 4 When the cleaned optical connector screwed back to adapter should notice to make force appropriate to avoid...

Страница 23: ...gy to install the active optical connector or the ceramic tape in the adaptor will lead to break Once the ceramic tape is broken the optical output power will decrease rapidly And turn the active optical fiber connector slightly the optical output power changes obviously c Please operate the optical fiber under the condition of shut off the pump laser Or the high output power will lead to burn the...

Отзывы: