14
www.combisteel.com
7.4
OVEN CONTROL SETTINGS AND ADJUSTMENTS
Test Point Pressure
The oven burner pressure test point is located also on the manifold test point on the top section. The test point
pressure is shown in the Nominal Gas Consumption Table.
7.5
CONVERSION INSTRUCTIONS
TO BE COMPLETED BY AN AUTHORISED PERSON
ENSURE GAS IS ISOLATED WHILE PERFORMING CONVERSION WORK.
PERFORM A LEAK TEST BEFORE IGNITING AND CALIBRATING BURNER
AND PILOT ADJUSTMENTS.
TO PROPANE GAS
Regulator
Change regulator to PROPANE gas configuration and adjust as necessary
Open Burner/Grill Burner
Access and change the injectors to PROPANE Gas injectors
(refer Nominal Gas Consumption Table)
Oven Burner
Access and change the injector to a PROPANE Gas Injector
(refer Nominal Gas Consumption Table)
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY ‘PROPANE’ GAS LABEL
TO NATURAL GAS (NG)
Regulator
Change regulator to NG gas configuration and adjust as necessary
Open Burner/Grill Burner
Access and change the injectors to a NG Injectors
(refer Nominal Gas Consumption Table)
Oven Burner
Access and change the injector to a NG Injector
(refer Nominal Gas Consumption Table)
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust
AMEND DATA PLATE AND APPLY ‘NATURAL GAS’ LABEL
SPARE PARTS
A list of major spare part items is shown at the end of this manual.
Содержание 7455.0900
Страница 55: ...55 www combisteel com EXPLODED VIEW 7455 0905...
Страница 56: ...56 www combisteel com BILL OF MATERIAL OF 7455 0905...
Страница 57: ...57 www combisteel com EXPLODED VIEW 7455 0915...
Страница 58: ...58 www combisteel com BILL OF MATERIAL OF 7455 0915...
Страница 59: ...59 www combisteel com EXPLODED VIEW 7455 0900...
Страница 60: ...60 www combisteel com BILL OF MATERIAL OF 7455 0900...
Страница 61: ...61 www combisteel com EXPLODED VIEW 7455 0910...
Страница 62: ...62 www combisteel com BILL OF MATERIAL OF 7455 0910...