6
CABINET CLEANING
Always unplug your cabinet before cleaning. Clean the cabinet with a warm wet wipe and some neutral
detergent, then wipe down with a dry cloth. Do wipe off the greasy dirt on the plastic parts avoid the
materials aging.
DO NOT use hot water, harsh chemicals, soap, abrasives, petrol, thinner, alcohol, organic solvents or brushes.
DO NOT wash machine with water directly in case of destroying the insulation.
Check and dry the plug and power cords after cleaning the machine.
Please use dry wipes when cleaning electric parts.
The machine can be used after cleaning and getting the inside dried.
Once power cut off, wait for at least 5 minutes before plugging in again to avoid damaging the compressor
or the system.
PACKING LIST
Model
7292.0005 / 7292.0010 / 7292.0015 / 7292.0020
User manual
1x
Defrosting shovel
1x
This product will be continuously improved. We reserve the rights of changing the component of the cooler,
without further notice, please accept our apologies.
TECHNICAL DATA
Model
Climate
Insulation
Power
Bulk
Rated
Rated
kW / h
Refrigerant
7292.0005
7292.0010
7292.0015
7292.0020
4/N
I
230V
49
180W
1.3A
3.24
R290
These data are tested under standard conditions, if any changes, please refer to the tag, this information may
alter without notice. The climatic class of the appliance is 4, it means that it can work in the ambient:
Dry bulb temperature °C Relative humidity %
Dew point °C
Water vapour mass in
dry air g/kg
30
55
20
14,8
DISPOSAL
Help protect the environment and human health. Put the packaging in applicable containers to
recycle it. Help to recycle waste of electrical and electronic appliances. Do not dispose appliances
marked with this symbol with the household waste. Return the product to your local recycling