7 INSTALLATION 

7.1 Before you Start 

You will need the following items and tools to complete the installation: 

i320W Bidirectional NMEA WiFi Interface 

Access to 12 V dc or 24 V dc power supply where the unit is to be installed, via a 1 A rated fuse 

or circuit breaker / or alternatively a USB cable connected to a USB power source. 

Four screws or other fixings appropriate to the mounting location 

7.2 Installing the Unit 

The i320W unit is not waterproof and should be installed in a dry location. The unit can be secured 
by the 4 mounting holes in the end flanges. It should ideally be installed in a location suitable for 
connection to power and NMEA cables. When installing the unit you should consider: 

  The  best  location  for  WiFi  transmission,  ideally  within  sight  of  the  device  you  wish  to 

connect to (Mount the device away from obstructions, that can have a negative impact on 
wireless performance. Also avoid mounting the unit behind any metal structures.) 

  Nearby interference that can impact your i320W Interface installation 

  Routing of the power cables to the unit 

  Provision of sufficient space behind the unit for cable connections 

  Maintaining the compass safe distance of 0.5m 

  Visibility of the front panel indicators 

7.3 Installation Step 1 

Secure the i320W to a flat surface in the selected location. Use four 5mm wood screws, or other 
fixings suited to the material the unit is being fixed to 

The unit may be installed in any orientation 

7.4 Installation Step 2 

Refer to section 7.5.1 Connection Diagram. Make the electrical connections to the i320W: 

Connect 12  V  dc  or  24  V  dc  power  supply  cables to  the  power  terminals.  The positive  power 

supply wire should be connected to the positive  terminal via a 1A rated fuse or circuit breaker. 
The  negative  power  supply  connection  should  be  connected  to  the  negative  terminal.  / 
Alternatively  you  can  power  the  device  through  the  USB  socket  connected  to  a  USB  power 
source. 

The i320W Bidirectional NMEA WiFi has two NMEA 0183 Inputs, NMEA IN 1 and NMEA IN 2. 

Per default, the NMEA IN 1 port is set up to a baud rate of 38400 and the NMEA IN 2 port to 4800 
baud. Both ports can be configured to different baud rates via the i320W Configuration Tool. 

Содержание AIS i320W

Страница 1: ...USER MANUAL i320W BIDIRECTIONAL NMEA WIFI INTERFACE SKU 001 1061 i320W MA v06r01 2019 11 17 ENGLISH...

Страница 2: ......

Страница 3: ...3 Setup Tool 14 8 3 1 Installing the i320W Setup Tool 14 8 3 2 Connecting to your i320W Read Data 14 8 3 3 Changing the configuration Write Data 14 8 4 Factory Reset 15 8 5 WiFi Modes 16 8 5 1 Access...

Страница 4: ...i320W 4 1 i320W BIDIRECTIONAL NMEA WIFI INTERFACE...

Страница 5: ...t Format PDF In PDF format the following categories are all enabled as active hyperlink references 1 The titles of each section 2 document cross references 3 the table of contents This document may th...

Страница 6: ...icated to any other person without the written permission of COMAR The recipient of this document as its registered holder must exercise due diligence in ensuring that the above conditions are observe...

Страница 7: ...development and product improvement hardware and software may be upgraded from time to time and future versions of equipment may therefore not correspond exactly with this manual When necessary upgrad...

Страница 8: ...ding position AIS data depth wind compass heading and more This manual describes the installation and operation of the i320W Before operating the unit you should familiarise yourself with this user ma...

Страница 9: ...i320W 9 6 MAJOR DIMENSIONS All dimensions in mm...

Страница 10: ...your i320W Interface installation Routing of the power cables to the unit Provision of sufficient space behind the unit for cable connections Maintaining the compass safe distance of 0 5m Visibility...

Страница 11: ...is operating Apply power to the i320W and all connected devices Verify that the green power LED on the i320W is illuminated Use a WiFi enabled device like a smartphone tablet or PC and search for WiFi...

Страница 12: ...i320W 12 7 5 1 Connection Diagram Note Input can be from any receiver or transponder with a serial NMEA output The R200U shown above is used as an example...

Страница 13: ...when powered NMEA IN 1 Flashing once with every NMEA message received at NMEA input 1 NMEA IN 2 Flashing once with every NMEA message received at NMEA input 2 NMEA OUT Flashing once with every NMEA m...

Страница 14: ...t your i320W to your computer using the USB cable Allow some time for the drivers to be automatically installed in the background This can take a few minutes After the device drivers have been success...

Страница 15: ...sources from the unit power cables as well as USB cable Using a paper clip push the reset button a click will be felt power on the device either through the power connection or the USB cable and hold...

Страница 16: ...one of the main modes 8 5 1 Access Point Mode Access Point Mode is set up as default Use this mode if the i320W is the only WiFi Access Point on your vessel Mobile devices can connect directly to the...

Страница 17: ...use the Client Mode To set the device into Client Mode select WiFi Mode Client in the i320W Configuration Tool In the SSID and WiFi Key fields fill in the settings of the Access Point you want to conn...

Страница 18: ...WiFi Mode Client in the i320W Configuration Tool In the SSID and WiFi Key fields fill in the settings of the Access Point you want to connect your i320W to Set up your phone as a WiFi Access Point als...

Страница 19: ...nd the other i320W to WiFi Mode Client The SSID and WiFi Key fields have to be the same info for both units Set one unit up as a TCP client and the other unit as a TCP Server In the Server IP field of...

Страница 20: ...ent is switched on Check polarity of the NMEA cables A A or B B or 9 3 Unable to see the i320W Network Move closer to the unit to improve radio reception 9 4 Unable to connect to the unit Retry connec...

Страница 21: ...s Finish Black Fine Texture Paint Grey ABS 10 2 Electrical Input Voltage 9 30 V DC Current 100mA 12V DC 10 3 Operational Input NMEA 0183 default 4800 Baud and 38 400 Baud Output NMEA 0183 default 38 4...

Страница 22: ...duct to be free from defects in materials and manufacture for one year from the date of purchase Comar Systems Ltd will at its sole option repair or replace any components that fail in normal use Such...

Страница 23: ...i320W 23 NOTES...

Страница 24: ...COMAR SYSTEMS Vittlefields Technology Centre Forest Road NEWPORT Isle of Wight PO30 4LY UNITED KINGDOM tel 44 0 1983 828900 email sales comarsystems com web www comarsystems com...

Отзывы: