ID-Mobile Global Guide
182
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
116
Description
The output closes at the beginning of prestart and opens if the engine shall be stopped.
This output can be used to indicate when the ECU should be powered up i.e. only while the engine is
running.
This output also influences evaluation of communication failure with ECU and related FLS alarms from
analog inputs read from the ECU. If the output is configured (which means configured on physical binary
output or VPIO output), the issuing of communication error is blocked during Prestart and Stopping
procedure as shown in the picture.
Note:
The output must be configured on physical binary output. It is not enough to configure it as a PLC
input for example.
ECU PowerRelay
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
263
Description
It activates, when RPM rises above starting RPM and opens when RPM=0.
Engine Running
Related FW
2.6.0
Related applications
AMF, MRS
Comm object
283
Description
Output is closed for 1 sec when Fault reset button (e.g. from DriveMonitor is activated).
FltResButtEcho