background image

 

Page 14 of 16

 

INSTRUCTION MANUAL

 

LI-150C 

LINE IMPEDANCE STABILIZATION NETWORK 

 

19121 El  T oro R d   ●  S il vera d o, Ca lifo rnia  926 76   ●   (94 9)  459 - 9600    ●  com - p ower.com

 

                

 

 

      REV021317   

7.0  T

YPICAL 

P

ERFORMANCE 

D

ATA

 

 

 

Figure 6: Typical Impedance compared to ANSI C63.5 & CISPR 16-1-2 requirements 

 

 

Figure 7: Typical Phase compared to CISPR 16-1-2 requirements. 

 

 
 

20 

30 

40 

50 

60 

70 

0.1 

10 

100 

Imp

ed

ance 

(ohms)

 

Frequency (MHz) 

LISN Impedance 

CISPR 16-1-2, 
Ed.1.2, Tbl 4 
(50uH) 
Impedance 
Limits (±20%) 

ANSI C63.4-
2009, Tbl B.2 
(50uH) 
Impedance 
Limits (±20%) 

-20 

-10 

10 

20 

30 

40 

50 

60 

70 

0.1 

10 

100 

Ph

ase 

A

ngle 

(d

eg

ree

s)

 

Frequency (MHz) 

LISN Phase 

CISPR 16-1-2, 
Ed.1.2, Tbl 4 
(50uH) Phase 
Limits (±11.5°) 

Содержание LI-150C

Страница 1: ...MANUAL LI 150C LINE IMPEDANCE STABILIZATION NETWORK 19121 El Toro Rd Silverado California 92676 949 459 9600 com power com REV021317 INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK Model L...

Страница 2: ...cription 10 5 1 Overview 10 5 2 Product Setup 10 5 3 Front Rear Panel Marking 11 6 0 LISN Theory 13 7 0 Typical Performance Data 14 8 0 Warranty 16 8 1 Maintenance 16 List of Figures Figure 1 Single P...

Страница 3: ...front and rear panel ports controls and indicators product specifications safety precautions operational instructions and warranty information and guidelines and instructions for its proper usage Info...

Страница 4: ...Networks CDN Comb Generators Current Probes Emissions Test Systems Conducted Immunity Test Systems Impedance Stabilization Networks ISN Line Impedance Stabilization Networks LISN Antenna Masts Near Fi...

Страница 5: ...e product The yellow triangle with a lightning bolt indicates an alert to the user that un insulated dangerous voltages are present within the product enclosure and on output connectors These voltages...

Страница 6: ...items ISO 17025 calibration data and certificate External transient limiter model LIT 153 3 4 General Safety Instructions The following safety instructions have been included in compliance with safet...

Страница 7: ...under EN 61010 1 standard safety requirements for electrical equipment for measurement control and laboratory use In addition the basic insulation required for a category I protection device cannot be...

Страница 8: ...b upon the instrument or use it as a step or ladder ENVIRONMENTAL CONDITIONS This equipment is designed for indoor use Ambient temperature range during operation should be between 5 C to 40 C STORAGE...

Страница 9: ...6 1 2 Edition 2 0 2014 03 ANSI C63 4 2014 Number of lines Two lines Max current rating 50 Amp AC 35 Amp DC Max Voltage rating 270 VAC 50 60 Hz Line to Ground 380 VDC Inductor type 50 H EUT Power conne...

Страница 10: ...eby minimizing its influence on the measurements and couples the disturbance voltages to the coaxial measurement port for connection to the measuring instrument like EMI Receiver or Spectrum Analyzer...

Страница 11: ...arth leakage current the device cannot be connected to any power source protected by either a ground fault circuit interrupter GFCI circuit breaker or residual current devices RCDs The power source mu...

Страница 12: ...3 4 EMI measurement Port The LI 150C provides a 50 N Type female connector to connecting the Spectrum analyzer or EMI receiver for making conducted noise measurements The shielding connection of the...

Страница 13: ...wever the power to the equipment passes through the LISN with minimal attenuation This filter is comprised of a single stage low pass LC filter The inductors L used in the LI 150C are air core type to...

Страница 14: ...pared to ANSI C63 5 CISPR 16 1 2 requirements Figure 7 Typical Phase compared to CISPR 16 1 2 requirements 20 30 40 50 60 70 0 1 1 10 100 Impedance ohms Frequency MHz LISN Impedance CISPR 16 1 2 Ed 1...

Страница 15: ...om power com REV021317 Figure 8 Typical Isolation compared to CISPR 16 1 2 requirements Figure 9 Typical Insertion Loss 20 30 40 50 60 70 80 90 100 0 1 1 10 100 Isolation dB Frequency MHz LISN Isolati...

Страница 16: ...directly or indirectly from the use or handling of this product or any inability to use this product separately or in combination with any other equipment When requesting warranty services it is recom...

Отзывы: