AC-220 Combilog Antenna
This section explains the following:
a)
Introduction
b)
Setup
Setup Procedure
2
2-1
2.0 Introduction
This section describes antenna setup and mounting for EMI measurement.
2.1 Antenna Setup
2.1.1
Connecting
The model AC-220 Combilog antenna has an 'N' type female I/O connector for
connection to measuring or source instrumentation.
2.1.2
Antenna setup for receiving signals
The model AC-220 antenna can be used to measure EMI from an equipment
under test (EUT). The antenna is mounted on either an antenna mast (model
AM-400) or an antenna tripod. The antenna has a universal mount (included) for
mounting on a tripod (AT-100) or other standard tripod. A cable is used to con-
nect the antenna to the measuring instrument. If a long cable is used, cable loss
must be measured and used in calculating the field strength.
2.1.3
Antenna setup for transmitting signals
The model AC-220 antenna can be used to transmit signals. The antenna is
mounted on either on an antenna mast (such Model AM-400 antenna mast ) or
antenna tripod. To transmit signals, the antenna is connected to a signal generator
and power amplifier. The Model AC-220 Combilog antenna can transmit up to
500 Watts continuous power. The field generated by the antenna can be measured
by using field strength meter.
Distributed by: Reliant EMC LLC, +1 408 916
‐
5750, [email protected], www.reliantemc.com