Columbus P-10 Pro Скачать руководство пользователя страница 2

3

P-10 Pro has three operating modes: Normal Mode, Motion
Detection Mode and Spy Tracking Mode.

Motion Detection Mode

How to enter this mode: Power on, short press the "Power
Button", the motion detection lamp (white) lights up.

When P-10 Pro is stationary, the lamp is on. When P-10 Pro is in
motion, the lamp is flashing. When P-10 Pro stops moving or
loses the satellite signal more than 5 minutes, it enters the
standby mode automatically. Once P-10 Pro detects motion, it
automatically wakes up and continues to log. This mode is
suitable for long time records of vehicles and other large
objects.

Spy Tracking Mode

How to enter this mode: In the power-off state, press the
"Power button" and the "Function button" simultaneously for
about 3 seconds.

In this mode, P-10 Pro gets positioned and logs 8 way points at
a certain time interval*. When P-10 Pro is standby, the main
status lamp intermittently flashes in blue. All other lamps on
the device are off and the speaker is mute. This mode is suitable
for tracking your car for an extended period, or for places where
charging is unavailable, e.g. in a long hiking.

* See page 5 for the value of the interval can be customized. See page 9 for the battery

life under different intervals. Spy tracking mode is only recorded at 1Hz, CSV format.

+

Log Mode

Power-off

Long press

Long press

Motion Detection
Mode

SPY Tracking
Mode

Normal Mode

Short press

Obtain the configuration file

For the first use, visit the link to obtain the default
configuration file which is named as CONFIG.TXT:

http: cbgps com/p10/config en.htm

//

.

Details about configuration

[SETTINGS]

TimeZone

SpeedAlert

AutoPowerOn

Beeper

-

12:00, -11:00, -10:00, -09:30, -09:00, -08:00, -07:00,-06:00,

-05:00, -04:30, -04:00, -03:30, -03:00, -02:30, -02:00, -01:00,

, +01:00, +02:00, +03:00, +03:30, +04:00, +04:30,

+00:00

+05:00, +05:30, +05:45, +06:00, +06:30, +07:00, +08:00,
+08:45, +09:00, +09:30, +10:00, +10:30, +11:00, +11:30,
+12:00, +12:45, +13:00, +13:45, +14:00

OFF

or value 1 200

: -

OFF

, ON

OFF,

ON

Values for conguration (the blue value is default)

Time zone. The default is UTC time (+00:00), please check your local time
zone in advance (for CSV les only).

Speed alarm. When the speed exceeds the value, the P-10 Pro will alert.
Short press the "POI Button" to temporarily stop.

Auto power on. When connecting to the MicroUSB cable, P-10 Pro
automatically turns On/Off with the power status.

Beeper. Turn On/Off the beeper.

Configuration steps

Turn off P-10 Pro. Connect P-10 Pro to the computer, copy the configuration file
under the root directory of the MicroSD card, and eject the device.

In the power-off state, press the "Power Button" and the "POI Button"
simultaneously until you hear 3 short beeps, then the 3 lamps will flash three
times at the same time, and finally you hear one long beep, indicating the
configuration is successfully completed.

+

x3

x3

Configuring the Device

Press simultaneously

Long beep

4

4

FunctionButton

Pause

, POI

Function Button. It can be congured for two purposes: POI or Pause.
Pause: Press this button to pause logging, press again to continue.
POI: Press this button to m ark the current position as the second type of
POI (for CSV les only).

[RECORD]

Format

LogMode

SpeedMask

SpyModeTimer

OneTrackPerDay

1Hz

,

5m, 10m, 20m, 50m, 100m
20ft, 50ft, 100ft, 200ft, 500ft

OFF or value

200

: -

1

1 - 60, default:

5

Values for conguration (the blue value is default)

Track format. P-10 Pro offers three original le formats: CSV (plain code
format), GPX (common exchange format), NMEA (NMEA 0183 format).

Log mode. By frequency, e.g.: 1Hz (1 trackpoint per second); By distance,
e.g.: 5m, 10m(Metric) / 20ft, 50ft(Imperial), (for CSV, GPX les only).

Speed mask: Only record the track points whose speed exceeding the
value

.

(for CSV, GPX les only)

Interval of Spy Tracking Mode: Set up the wake up interval (minute).

OFF

, ON

One track per day. OFF: A new le is generated each time it is turned on.
ON: Only one le is generated per day, and all the tracks are automatically
merged into one track.

CSV

, GPX, NMEA

[UNIT]

Speed

Values for conguration (the blue value is default)

km/h

, mi/h

Tips about configuration error

Users can customize the configuration, only limited to the contents and formats
listed in the above table (case sensitive).

Attention! The configuration cannot take effect if the configuration value does not
conform to the format and content requirements. In case of abnormality, the main
status lamp will flash in red, and the buzzer will give 5 short beeps as an error
prompt. Please check the configuration values and fix it.

x5

+

Red
flashing

Configuration
failure

Check the
configuration

5

5

Speed Unit: km/h (Metric), mi/h (Imperial).
This conguration is only valid for SpeedAlert and SpeedMask.