SU5-S/L
Page 24
CHARGER LED INDICATORS
The charger includes three (3) LEDs to indicate charger status and fault information. The
functionality of the LEDs is outlined below. If the charger is equipped with a remote LED
assembly, this assembly also includes three (3) LEDs with identical functionality.
YELLOW
Indicates charge cycle status. See descriptions of the possible states.
GREEN
Indicates when a charge cycle completes successfully, when an extended Equalize charge
cycle phase is active, or when a post-charge float phase is active. See descriptions of the
possible states.
RED
Indicates when a charger or battery fault has occurred. See descriptions.
Red LED
Yellow LED
Green LED
Description
C
H
A
R
G
E
R
C
O
N
D
ITI
O
N
S
Slow Blink
1
1
DC has been disconnected but charger
still plugged in
Slow Blink
0
1
Over Temp
– Cycle will restart when
temperature decreases.
Slow Blink
1
0
LOW DC
– Battery voltage too low to
begin cycle. Check batteries and
connections.
Slow Blink
0
0
No AC
– Power was lost during cycle.
Cycle will restart when power returns.
Slow Blink
1
Slow Blink
INTERNAL FAULT
– Contact Columbia.
Slow Blink
Slow Blink
0
INTERNAL FAULT
– Contact Columbia.
Slow Blink
Slow Blink
1
INTERNAL FAULT
– Contact Columbia.
Fast Blink
N/A
N/A
INTERNAL FAULT
– Contact Columbia.
Unit is still able to charge.
B
A
TT
E
R
Y
C
O
N
D
ITI
O
N
S
1
0
0
PHASE
– A fault condition occured during
a cycle. (Most commonly maximum time
in one phase).
1
0
Slow Blink
MAX DC
– Maximum voltage has been
reached.
1
0
1
MIN DC
– Minimum voltage was not met
after a specified time from the start of
cycle.
1
Slow Blink
0
MAX AMP
– Maximum amp-hour for
overall cycle met.
1
Slow Blink
Slow Blink
MAX TIME
– Maximum time for overall
cycle was met.
Yellow LED
Green LED
Description
Slow Blink
Off
Bulk/Start charge cycle phase.
Fast Blink
Off
Absorption charge cycle phase. (Great than 80%
charged)
Solid On
Off
Finishing charge cycle phase.
Off
Fast Blink
Equalize charge cycle phase.
Off
Solid On
Charge cycle complete.
Off
Slow Blink
Charge cycle complete. Float charge cycle active.