IMPORTANT INFORMATION
The type of battery used in a Columbia vehicle has a service requirement which is quite different from that of an
automotive battery.
The electric vehicle battery supplies all of the power to drive the vehicle. During operation the power stored in the
batteries is expended. While the amperage drain rate can vary greatly depending on the type of service, the duration
of use and the number of "starts" and "stops" made during a day, the batteries nevertheless progress through each
duty cycle from "fully charged" to an almost depleted state.
This type of service is known as "deep cycle" service and electric vehicle batteries are specifically designed to handle
this type of service. Proper performance of your Columbia vehicle can only be obtained from specified deep cycle,
electric vehicle batteries.
PLEASE REVIEW IMPORTANT DANGER, AND WARNING STATEMENTS WHEN WORKING AROUND
BATTERIES AND CHARGING SYSTEMS!
Always remove key and disconnect battery pack before servicing or repairing the vehicle. See
SECTION 2
SAFETY,
BATTERY DISCONNECT METHOD.
Always wear full-face shield when working on or near batteries.
All batteries used in electric vehicles can explode! Batteries produce explosive hydrogen gas at all times,
especially, during charging or discharging. Ventilate area when charging batteries.
Do not attempt to charge a battery if it is frozen, or if the case is bulged excessively. Frozen batteries can
explode! Properly dispose of the battery.
Do not smoke around batteries. Keep sparks and flames away from batteries and the charging area. Use
care to prevent an accidental arc which could cause an explosion. Use only approved insulated tools,
remove jewelry such as rings, watches, chains etc. and place an insulating material (wood, plastic, rubber
etc.) over all battery connections.
Never add acid to a battery.
Battery acid is poisonous and can cause severe burns. Avoid contact with skin, eyes, or clothing.
ANTIDOTES:
EXTERNAL: Flush with water. Call a physician immediately.
INTERNAL: Drink large quantities of milk or water. Follow with milk of magnesia or vegetable oil. Call a
physician immediately.
EYES: Flush with water for fifteen minutes. Call physician immediately.
To reduce the risk of electrical shock or injury:
Do not use an ungrounded two to three-prong adapter to connect the charger to a two-prong outlet or
extension cord.
The battery charger must be properly grounded. Use a three prong No. 12 AWG heavy duty power cord no
more than 50 feet long.
Locate all cords so that they will not be stepped on, tripped on, or otherwise damaged. Immediately
replace worn, cut, or damaged power cords or wires.
Do not connect the power cord near fuels, grain dust, solvents, thinners, or other flammables. The spark
can ignite flammable materials and vapors