3
RATINGS
Boiler Model
Number
Oil Burner Input
(1)
Capacity
MBH
(4)
Net AHRI Ratings
(3)
Min. Natural Draft
Chimney Size
A.F.U.E.
Rating
WITHOUT
TANKLESS
WITH
TANKLESS
G.P.H.
MBH
(2)
Steam
MBH
Sq. Ft.
Steam
Round
Square
CSFE -3090 S CSFE
-3090 ST
0.90
126
106
80
333
6
8"x8"x15'
82.0
CSFE -4125 S CSFE
-4125 ST
1.25
175
147
110
458
6
8"x8"x15'
82.0
CSFE -5185 S CSFE -5185 ST
1.85
259
216
162
675
8
8"x8"x15'
82.0
CSFE -6210 S
CSFE-6210 ST
2.10
294
247
185
771
8
8"x8"x15'
82.0
NOTES:
(1)
Burner input is based on an oil heating value of 140,000 Btu/gal.
(2)
MBH = 1000 Btu per hour [Btu = 15 Amps, 60 Hz
RATINGS, DATA
TANKLESS WATER HEATER CAPACITIES
Boiler Model
Number
Input
Rate
G.P.H.
Tankless
Heater
Number
Tankless
Heater Capacity
Intermittent Draw
G.P.M.
Boiler Water
Content
(Gallons)
To Water
Line
To
LWCO
Line
CSFE-3090 ST
0.90
L-24
2
11
8
CSFE -4125 ST
1.25
L-24
4½
13
9
CSFE -5185 ST
1.85
L-24
4½
15
10
CSFE -6210 ST
2.10
L-24
4½
17
11