HYDROSTATIC PUMP

FINE ADJUSTMENT

The only time fine adjustment would be made is if electrical pin

has been disconnected and vibrator is still slightly rolling over.

Look at the acceleration and deceleration gauges.  These will be the two outside gauges.

You will notice that at this time one of the gauges will have a higher reading then the

other.

With electrical pin connector disconnect from EP controller insert flat tip screwdriver into

adjustment screw slot and hold adjustment screw from turning while breaking jam nut

loose.  While making your adjustment watch the gauges and with very slight adjustment

right or left of the adjustment screw you will notice one of the gauges increase in

pressure.  Turn the adjustment screw the opposite direction and the other gauge will

start to increase in pressure.  Turn the adjustment screw back until both gauges read

the same pressure.  At this time hold the adjustment screw and lock the lock nut down.

Again check the gauges to make sure pressure are the same.  Some times it may be

necessary when locking down the lock nut you may need to slightly turn the adjustment

screw back so when locking the lock nut down your pressures will be equal.

At this time your vibrator should not be rolling over.

If the vibrator is still rolling over and you cannot equal the pressures on both gauges you

will need to make adjustment to the course adjustment to center the pump and then

return to the fine adjustment procedures again once you have completed the course

adjustments.

NOTE

For fine adjustment

jam nut and slotted

screw is located here.

Содержание AA4VG71

Страница 1: ...off locked out tagged out and all moving parts have come to a complete stop and or blocked to prevent movement Machinery is dangerous avoid personal injury and or death by following manufacture Local...

Страница 2: ...ON This manual provides information applicable to the Columbia Block Machine 16HF 1600 manufacturing systems equipped with the Hydrostatic drive CONTENTS Adjusting Relief Valves 2 FineAdjustment 4 Cou...

Страница 3: ...wrench On 125 and 180 to be done with a 5 mm allen wrench and a 17 mm box wrench For new pump replacement check to ensure that the orifice plugs in Port X1 and Port X2 have been removed If orifice plu...

Страница 4: ...set at 2500 psi For the AA4VG71 and AA4VG90 one turn equals 2200 psi 150 bar 6 Remember one complete turn clockwise on AA4VG71 and 90 equals 2200 psi 150 bar 7 Make sure that the POR valve is not in...

Страница 5: ...f the gauges increase in pressure Turn the adjustment screw the opposite direction and the other gauge will start to increase in pressure Turn the adjustment screw back until both gauges read the same...

Страница 6: ...ill notice gauges installed in Ma and Mb ports these are the two outside gauges which we refer to as acceleration and deceleration which you will be reading for the following procedures You do not hav...

Страница 7: ...ID The port sizes are as follows Size 28 90 7 16 20 UNF Size 125 250 9 16 18 UNF Pump Size Allen Wrench Wrench 28 56 6 mm 19 mm 71 90 6 mm 24 mm 125 250 8 mm 24 mm With pressure gages installed at Ma...

Страница 8: ...ge Pressure Relief Valve Adjustment ForAA4VG28 AA4VG56 With pressure gauge installed at G port run pump at normal operating speed and temperature If pressure is low remove relief valve and add shim s...

Страница 9: ...TIC PUMP REMOVAL INSTALLATION OF SHAFT SEAL Remove the retaining ring with snap pliers Screw in sheet metal screw into the holes fitted with rubber Pull out shaft seal with pliers Press in shaft seal...

Страница 10: ...If the thermostat is good check the oil cooler three phase lockout and the start overloads and fuses If all are good then check the oil cooler motor Is the heater set too high or not shutting off Rem...

Страница 11: ...motor 5 Case drain return from hydraulic motor 6 Gate valve shut off 1 2 3 4 5 6 1 Deceleration pressure MA 2 Charge pump pressure G 3 Acceleration pressure MB 4 Return filter high pressure 5 Heat ex...

Страница 12: ...mp Unit 1 Pump case drain 2 Filter out to FA port 3 Filter in from FE port 4 X2 Port 5 X1 Port 6 POR Valve 7 Null fine adjustment 1 2 3 4 5 6 7 1 2 3 4 5 7 8 1 Fan motor 2 Fan switch 3 Low oil 4 Over...

Страница 13: ...HP Hydrostatic Pump Unit 1 G port charge pump pressure 2 MB gauge port acceleration 3 MA gauge port deceleration 4 Null course adjustment 5 Detent pin override on EP controller valve 6 Acceleration r...

Страница 14: ...egrees Part 2327616 2 Low oil switch shut down Part 237089 3 Over temperature 150 degrees shut down Part 232618 2 Low Oil 3 Over Temperature 1 Fan Switch High pressure pump filter Heat exchanger motor...

Страница 15: ...Columbia Concrete Products Page 14 1 04 HYDROSTATIC PUMP Return Filter and filter indicator gauge Oil level sight gauge and oil Temperature Oil tank reservoir 40 50 HP Hydrostatic Pump Unit...