2
COLUMBIA SPECIFICATIONS
1622 Browning Irvine, CA 92606-4809 Phone: 949.474.0777 Toll Free: 800.626.2117 Fax: 949.474.1191
www.columbiasinks.com
email: info@
columbiasinks.com
©2019 Columbia Products
FLOOR MOUNTED SCRUB SINKS
Tools Required
Tape Measure
Adjustable Wrench
Drill Motor and Drill Bits
Pipe Wrench
Level
Safety Glasses
Screw Drivers: 1 Phillips & 1 Standard
Pencil
Socket Wrench
Installation Instructions
Step 1
1. 1. Attach upper and lower leg support brackets to legs with hardware (provided).
2. Place wash station sink on the leg assembly. Secure legs to bowl with hardware provided.
3. Place wash station sink at the desired location.
4. Mark the floor where the mounting holes are at the base of the legs. See illustration A.
5. Drill holes as required for mounting hardware. Hardware not included.
Step 2
1. Install Faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position wash station sinks to pre-drilled holes and secure sink to the floor.
2. Connect waste line or drain pipe to the strainer assembly. Not included.
3. Connect water supply lines (Hot and Cold) to the water source. Not included.
4. Remove aerator from the spout and flush the water system.
5. Replace aerator to the spout.
6. Check for leaks and tighten connections if necessary.
Step 4
1. Seal gap between bowl and leg assembly as shown in illustration B.
2. When mounting against wall, it is recommended sealing the top of the backsplash to wall as
shown on illustration C.
Parts List
(1) Floor mount sink
(1) Leg assembly set
(4) Washers and nuts for connection sink to leg assembly set
(1) 8” on center faucet
(1) Faucet mounting kit
(1) Strainer assembly with basket
Trouble Shooting Guide
Problem
Possible Cause
To Diagnose
Remedy
Water drips
from the spout
or from under
the lever.
1. Seat washer is worn
2. Seat is worn
3. O-rings are worn
Shut cold water source
off. See if water still leaks
from the spout. If leaks
continues repair hot side
if not repair cold side.
Recommend
installing hot
or cold faucet
repair kit.
WARNING:
This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
.
NOTE:
Lead content originates from Brass components in valves and faucets and is certified under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers