background image

   


 

CARBON DIOXIDE DETECTOR 

This device monitors and tracks levels of indoor carbon dioxide, temperature, and humidity. 
Carbon dioxide is a greenhouse gas breathed out by people and absorbed by plants. Too much 
carbon dioxide in the air can make people sick. This device has a buzzer that indicates when 
the carbon dioxide levels have reached undesirable levels. Carbon dioxide, temperature, and 
humidity are logged and downloaded using the free computer software program (optional). To 
install the free software to the computer (Windows PC): 

1.

 

Go to CO2Meter.com/pages/downloads and download the XT-10 Setup file.  

2.

 

Double click the setup file when do

wnloaded and click “Next” to begin

.  

3.

 

Accept the default installation folder to your hard drive or click “Browse” to create a 

new folder.  

4.

 

Click “Next” to confirm the 

installation and 

click “Next” again to start the 

installation.  

5.

 

Once the installation is c

omplete, click “Close

.

 

Note: 

 

Before the first time the device is used or when the screen displays a low battery, it 
will need to be charged using either a wall adapter or a USB cable port on a 
computer. The device can still be used while it is charging. An explanation of the 
various buttons on the device from the instruction manual are shown in 

Figure 3

. 

Here is how to use your detector: 

1.

 

Try not to breath directly on the device. 

2.

 

To turn on the device, press the Power button on the back. A 30-second countdown 
will be displayed as the device powers up. 

3.

 

To set the CO2 alarm level, date, and time, press and hold the MODE button for 2 
seconds.  

a.

 

The first option will be to set the CO2 alarm level. Using the left and right 
arrow buttons, select the digit you wish to change and use the up and down 
arrows to change the selected digit (selected digits will flash). The default 
setting is 2,000 PPM (parts per million), which is the suggested maximum for a 
healthy environment

Figure 4

 shows ranges of carbon dioxide concentrations 

and their associated impacts on health. 

b.

 

Press and hold the MODE button for 2 seconds to move to the date settings. Set 
the date to today if it is not already correctly set. Using the left and right 
arrow buttons, select the digit you wish to change and use the up and down 
arrows to change the selected digit (selected digits will flash).  

c.

 

Press and hold the MODE button for 2 seconds to move to the time settings. 
Change the time to the current time if it is not already correctly set. Using the 
left and right arrow buttons, select the digit you wish to change and use the up 
and down arrows to change the selected digit (selected digits will flash).  

Содержание KILL A WATT EZ

Страница 1: ...ENERGY SAVINGS FOR SCHOOLS How to use the tools in your kit ...

Страница 2: ...ioxide Detector 5 URCERI Light Meter 9 Images Right Energy Savings for Schools Colorado Energy Office 2018 ColoradoESS org Below High Performing School Program Colorado Energy Office 2018 https www colorado gov pacific energyoffi ce high performing school program ...

Страница 3: ...rate your watt meter 1 Plug the watt meter into an electric outlet Ensure that the appliance you want to check is turned off and then plug the appliance into the watt meter 2 To reset the meter press and hold the RESET button until rEST appears on the screen Release the RESET key This indicates that all previously recorded measurements have been erased and reset to zero 3 Program the price you pay...

Страница 4: ... the meter the more accurate the estimate will become especially for appliances that are used periodically such as televisions and refrigerators Appliances like computer servers that are never turned off will have accurate cost estimates within minutes as they do not cycle through periods of ON and OFF 5 To change the type of power being measured press the MENU key until Volt is displayed on the s...

Страница 5: ...les in the air For maximum accuracy place the monitor in a clean dry area out of direct sunlight and away from any heat sources vents or humidity sources An explanation of the various buttons on the device from the instruction manual are shown in Figure 2 Figure 2 Features of the Humidity Monitor from the Instruction Manual Here is how to use this monitor 1 Install 2 AAA batteries into the battery...

Страница 6: ...monitor until dashes appear in place of the numbers 4 To calibrate the real time temperature and humidity being displayed press and hold all three buttons UP wrench DOWN on the back of the device at the same time until the screen clears leaving the humidity value flashing Use the UP and DOWN arrows to adjust the humidity as needed Press the wrench button to move to calibrating the temperature Use ...

Страница 7: ...n the device from the instruction manual are shown in Figure 3 Here is how to use your detector 1 Try not to breath directly on the device 2 To turn on the device press the Power button on the back A 30 second countdown will be displayed as the device powers up 3 To set the CO2 alarm level date and time press and hold the MODE button for 2 seconds a The first option will be to set the CO2 alarm le...

Страница 8: ...and time can be synced to the computer s built in clock by connecting the device to the computer using the USB cable and clicking Set Time in the software program Figure 3 Features of the CO2 Detector from the Instruction Manual ...

Страница 9: ...graphically Here is how to calibrate the device if necessary Automatic Baseline Calibration This option is used in areas that are regularly unoccupied meaning that the CO2 levels have the opportunity to return to 400 PPM every few days 1 Turn off the device 2 Press and hold the up arrow and down arrow buttons then press the Power button Release the Power button first then release the arrow buttons...

Страница 10: ...nical support at support co2meter com 386 256 4910 Notes If the CO2 levels are higher than the selected alarm level a buzzer will sound Press the left arrow button to turn on off the buzzer on the main display screen Carbon dioxide guidelines are shown in Figure 4 Figure 4 Carbon Dioxide Level Guidelines Provided in the Instruction Manual The device s data logging memory is reset whenever the devi...

Страница 11: ...oto detector 3 Use the Power button to turn on the device a When the meter is off holding down the FC LUX button then pressing the Power button changes the power settings If the Auto Power Off icon shows on the screen the device will automatically turn off after 15 minutes If the Auto Power Off icon is not on the screen the screen will need to be turned off manually by pressing the Power button 4 ...

Страница 12: ...Hold on 8 To change the temperature units turn off the device While holding down the Hold button press the Power button 9 When done with the device replace the photo detector cap and remove the batteries Table 1 presents recommended light levels for spaces within schools as a reference Table 1 Recommended Light Levels in Schools Space Recommended illumination foot candles Hallway 5 10 Classrooms 2...