![Colombo Construction 54LL Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/colombo-construction/54ll/54ll_owners-manual_2637585010.webp)
HOT SURFACE IGNITION PILOT LIGHT
54 - 68 LL and NL ELECTRONIC IGNITION FIREBOWL
COMPONENTS
PARTS AND INSTALLATION
OVERVIEW
10
All replacement parts may be ordered
by calling Colombo Construction Corp.
718.399.2233 or 212.334.5069 or by
emailing [email protected]
68L FIREBOWL
REGULATOR
MUST BE PROPERLY VENTED IN CLOSED SPACES
1/2" GAS LINE TO PILOT
3/4" GAS LINE TO BURNER
8” x 3/8” EXPANSION ANCHOR BOLT (3X)
3/4" ELECTRICAL CONDUIT 24V
LINES TO PILOT ASSEMBLY
36" OR TO LOCAL
FROST CODES
24" SONOTUBE FOUNDATION
12 GUAGE WIRE FOR RUNS SPECIFY IN FEET
FIREFEATURE ON/OFF SWITCH
LOCATED ON FRONT PANEL OF BOX
24 VOLT - AC TRANSFORMER
110V ELECTRICAL FROM SERVICE PANEL
10"
PILOT BURNER
GAS SYSTEM ACCESS
A
SECTION
GAS IN FROM SERVICE
ALL WEATHER ELECTRONIC
IGNITION SYSTEM
HOUSING INCLUDES
SOLENOID VALVES AND
CONTROL MODULE
3/4" NPT 512,000 BTU
TOP VIEW
SECTION A - FIRE SYSTEM UTILITIES
PLAIN VIEW SHUT OFF VALVE
MOST BE WITHIN 10' OF FIREFEATURE
OR TO LOCAL CODE
54LL FIREBOWL
ELECTRICAL
MAIN GAS
PILOT GAS
SLEEVING GAS LINE
12 11/16"
10 3/4"
54NL FIREBOWL
68NL FIREBOWL
18"
FINISH GRADE
54FIREBOWL
WITH ELECTRONIC IGNITION
54" DIA
68FIREBOWL
WITH ELECTRONIC IGNITION
68" DIA
A
SECTION
FIBERGLASS ENCLOSURE (NEMA 4X),
HINGED COVER WITH 1/4-TURN LATCH,
13.2" X11.2" X 6.6"
ALL FITTINGS ARE STAINLESS STEEL
MUST BE INSTALLED ABOVE GRADE