2, Set the function switch to the position of CAP, the LED above the jack (V/
Ω
/F/
CAP)
will shine.
3, Insert the black test lead banana plug into the negative (-) jack (COM) and the red test lead
banana plug into the positive (+) jack (V/
Ω
/F/
CAP).
NOTE
: The meter will be in Auto ranging. If you wish to manually set the range, do so
following instructions in the Description (4.1Diagram item7) section of this manual. For
manual ranging, start at the highest range and work down.
4, Touch the test probe tips across the devise under test.
(The red probe to Positive and the black to Negative).
5, Read the value and unit shown on the display. If OL displayed, the value of the capacitor
is over the maximum range of the meter.
4.2.10 Frequency Measurement
1, Set the function switch to the position of FREQ, the LED above the jack (V/
Ω
/F/
CAP)will shine.
2, Insert the black test lead banana plug into the negative (-) jack (COM) and the red test
lead banana plug into the positive (+) jack (V/
Ω
/F/
CAP).
NOTE
: The meter will be in Auto ranging. If you wish to manually set the range, do so
following instructions in the Description (4.1Diagram item7) section of this manual. For
manual ranging, start at the highest range and work down.
3. Press the FREQ %duty button once, the “H
z
” will appear on the display.
4, Touch the test probe tips across the devise under test.
5, Read the value and unit shown on the display.
CAUTION:
Never inputting the voltage over 250V AC/DC!
4.2.11 Duty Cycle Measurement
1, Set the function switch to the position of FREQ, the LED above the jack (V/
Ω
/F/
CAP) will shine.
2. Insert the black test lead banana plug into the negative (-) jack (COM) and the red test
lead banana plug into the positive (+) jack (V/
Ω
/F/
CAP).
3, Press the H
Z/
% button twice, the “%” will appear on the display.
4, Touch the test probe tips across the circuit under test.
5, The duty cycle and % will be shown on the display.
CAUTION:
Never inputting the voltage over 250V AC/DC!
4.2.12 Temperature Measurement (with special K-Type temperature probe Colluck Model KTP-2)
1, Set the function switch to the position of TEMP.
If you wish to measure temperatures in , set the function switch to the range. If you
wish to measure temperatures in , set the function switch to the range.
2. Insert the banana plug of temperature probe marked “-“ into the negative (-) jack (COM)
and the banana plug of temperature probe marked “+” into the positive (+) jack (mA/µA
TEMP).
3, Touch the Temperature Probe Head to the part whose temperature you wish to measure.
Keep the probe touching the part under test until the reading stabilizes (About 30
seconds).
4, Read the temperature on the display. The digital reading will indicate the proper decimal
point and value.
CAUTION:
(1) Do not measure temperatures of metal parts when any voltage is present on
them.
(2) Use only special K-type temperature probe Colluck Model KTP-2.
4.2.13 Relative Value Measurement
During the measurement of the reference or base value, press the Relative button.
The “
∆
” will show on the display and the Value will be stored in memory as a reference for
future use. At the following measurement, the display will only show the different value
between the measured device and base unit. To cancel this function, press the “REL” button
until “
∆
” disappeared on display.