Ini琀椀al start-up
Mixing tool and HEXAFIX coupling
Mixing tub
Check that the power supply shown on the ra琀椀ng plate is the same as the mains power supply.
Connect the machine power cable to the mains power outlet via a suitable extension cable (type
H07 RN-F, min. diameter 1.5
2
). This must have a fault current circuit-breaker (e.g. earth-leakage
circuit-breaker/RCD).
Check that the mixing tub is correctly held in the mount and that the 琀椀pping device is locked.
Also check that the cover plate is on the tub and is locked.
If you connect an external dust extractor, connect the extractor hose to the hose fitting on
the cover.
The DLX mixing tool is specially designed for liquid, low-viscosity materials. The high shear forc-
es of the mixing tool break up lumps quickly and produce a homogeneous mix in a short 琀椀me.
The mixing tool is connected to the drive unit by a HEXAFIX quick-ac琀椀on coupling. It can there-
fore be 昀椀琀琀ed and taken out without the need for any other tools.
Prior to opening the machine, pull out the power plug.
•
The drive unit must be li昀琀ed to enable the mixing tool to be removed. To do so, release
the lever at the back. Li昀琀 the drive unit by the bow-type handle un琀椀l it engages in the 昀椀rst
posi琀椀on.
•
Push the red part of the HEXAFIX coupling upwards. This releases the s琀椀rrer to enable it to
be pulled downwards and out.
•
To 昀椀t the s琀椀rrer, push it into the coupling un琀椀l it engages in the coupling.
•
Release the cover again and close it.
The HEXAFIX has a rubber bushing to protect it from dirt. The bushing can be replaced if re-
quired. To ensure that the coupling o昀昀ers las琀椀ng service, apply a li琀琀le grease (not oil!) to it at
regular intervals.
The mixing tub has a changeable pouring spout. This is to help pour the mix cleanly and on
target.
•
To take out the mixing tub you 昀椀rst have to take out the mixing tool (see above).
•
Once that has been done, you have to swing the complete drive unit fully upwards. Release
the drive element by the release lever and li昀琀 it un琀椀l it engages in the maximum posi琀椀on.
•
CAUTION:
The drive unit is heavy; hold it 昀椀rmly by the bow-type handle while opening and
closing. If not, there is a risk of your 昀椀ngers ge琀�ng crushed. Be aware that there is an in-
creased risk of the machine toppling over when it is open.
•
To take out the tub: Turn it a li琀琀le un琀椀l the handle on the tub is no longer blocked by the
handle. Then li昀琀 it out of the tub holder.
If a new replacement tub is to be used, the pouring spout has to be switched over. This is fas-
tened to the tub by 6 screws.