Operation 

Prior to working with the machine, check all parts for their proper condition and function. Do not 

start the machine with defective or missing parts.  
Check all safety-relevant structural components of the machine for proper function before starting 

it. Any defective or damaged parts must be replaced by qualified personnel prior to starting to work 

with it. 

 

6.1

 

Switching on the machine 

The machine is turned on using the main switch (3).  

After an automatic initialisation, 

READY

 is shown on the display.  

Any errors detected during initialisation are shown in text form on the display. 

 

6.2

 

Open the door (starting position) 

By pressing button 

DOOR

, the door is opening. The display indicates 

READY

, the machine is ready 

for mixing. 

6.3

 

Load a container 

Only use sufficiently stable and tight-closing vessels for mixing. In case of doubt, consult the 

manufacturer of the mixing vessels.

 

To place the container, proceed as follows: 

 

The machine must be in starting position, see 6.2 

 

Observe the weight and size limits of the mixing vessel. Never overload the machine! 

 

Place the container centrically on the mixing table. Place the handle to the rear side against the 

rubber band for handle fixation.  

 

If  diameter is smaller than 270mm, secure the container handle with a rubber band or an 

adhesive.  

 

Use only undamaged containers, never stack containers! 

 

 

 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

Securing the handle with 

a rubber band

 

          

 

 

 

Do not stack containers!

 

Содержание BIAX 45P

Страница 1: ...Version 1 7 18 Instructions Biaxial Mixer BIAX 45P Keep this manual within immediate reach of the machine Translation of the original instructions en Englisch ...

Страница 2: ...BIAX 45P Collomix GmbH 2 Version 1 7 18 ...

Страница 3: ...5 6 Trial run 11 6 Operation 12 6 1 Switching on the machine 12 6 2 Open the door starting position 12 6 3 Load a container 12 6 4 Starting the mixing cycle 13 6 5 Ending the mixing cycle 13 6 6 Close the door parking position 13 6 7 EMERGENCY STOP switch 13 7 Errors and Troubleshooting 14 7 1 Possible errors 14 7 2 E080 MU unlocked 15 7 3 Unlock door manually 16 7 4 Fuses on the device 16 7 4 1 D...

Страница 4: ...ersion 1 7 18 1 Layout Drawings 1 1 Machine components Machine components 1 Machine legs 5 Manual door release 2 Sliding door 8 Control panel CSE 3 Main switch and main fuse 7 Lower clamping plate 4 Emergency Stop 2 3 4 5 7 6 1 ...

Страница 5: ...N the mixing unit STOP stop mixing cycle prematurely ACKNOWLEDGE messages Button I Mixing cycle I Factory settings 1 00 Minute Button II Mixing cycle II Factory settings 1 00 Minute Button III Mixing cycle III Factory settings 1 00 Minute For changing the Mixing times please contact an authorized service technician ...

Страница 6: ...he corresponding precautionary measures WARNING This signal word is used if death or severe physical injuries may result from not paying attention to the corresponding precautionary measures ATTENTION This signal word is used if slight physical injuries occur from not paying attention to the corresponding precautionary measures CAUTION This signal word is used if malfunction of functions or proper...

Страница 7: ... before working with the machine Keep the Operating Instructions within immediate reach of the machine Please hand the Operating Instructions to any subsequent owners 3 1 General Safety Information The basic safety information of this Chapter is supplemented by precise warnings in further chapters of the Operating Instructions 3 2 Intended Use The biaxial mixer is intended to mix Colours Colour gr...

Страница 8: ...bvious malfunctions Repair cleaning and maintenance work without disconnecting the system from power WARNING Danger of injury through improper modifications Hazards exist through unauthorized modifications to the system and the use of third party spare parts Use only original spare parts and accessories of the manufacturer Do not change add to or retrofit the system without the consent of the manu...

Страница 9: ...e mixing vessel is released Never operate the machine if the machine door is damaged EMERGENCY STOP Switch In emergencies the EMERGENCY STOP switch to halt the machine if needed 3 6 Residual Risks If all precautions are taken there may be obvious residual risks Adhering to the safety instructions the designated use and the operating instructions as a whole can reduce residual risks 4 Equipment Des...

Страница 10: ... or on any other suitable sub surfaces Before installation ensure that there is a sufficiently large working area available in front of the machine The doors of the machine may not protrude into aisles or travel paths when opened Check the level of alignment and the stability of the machine with a spirit level Adjust any unevenness in the floor with the height adjustable legs 1 The optionally avai...

Страница 11: ...e of installation on the cartridge The lubrication is guaranteed for approx 12 month In multi shift operation in continuous operation with full load or with cycle times of more than 10 minutes it may be necessary to increase the lubricant quantity In this case the PERMA cartridge must be replaced at the latest after 9 months Please read the accompanying original PERMA documentation 5 6 Trial run A...

Страница 12: ...the display 6 2 Open the door starting position By pressing button DOOR the door is opening The display indicates READY the machine is ready for mixing 6 3 Load a container Only use sufficiently stable and tight closing vessels for mixing In case of doubt consult the manufacturer of the mixing vessels To place the container proceed as follows The machine must be in starting position see 6 2 Observ...

Страница 13: ...ng the DOOR button When done working switch the machine off at the mains 3 6 7 EMERGENCY STOP switch In dangerous situations the machine can be turned off with the EMERGENCY STOP switch After the EMERGENCY STOP button is pressed the mixing unit will coast to a standstill and remain in this position The mixing unit is not moved automatically to the 12 o clock position Reset the EMERGENCY STOP switc...

Страница 14: ...ner is defect Container is unstable Check clamping pressure if necessary adjust E070 Mixing Unit locked Latching pin blocked The latching pin is blocked clean and lubricate replace if necessary Latching pin released Check the lead connector to the switch of the mixing unit lock The switch of the mixing unit lock is defective E080 Mixing Unit unlocked Latching pin blocked The mixing unit is not 12 ...

Страница 15: ...s upon actuation of the EMERGENCY STOP button or upon interruption of the power supply during the mixing process AUTO With the container clamped or the mixing unit not loaded the mixing unit can be automatically positioned and fixed with the help of Button I Auto MANU With the mixing container unclamped the mixing unit must be positioned manually Upon actuation of Button III MANU the door can be o...

Страница 16: ...s by pulling out the mains plug Never use the manually door unlocking device whilst the mixing unit is turning 7 4 Fuses on the device 7 4 1 Device fuse If line voltage is available but the power button does not light up the cause may be a faulty device fuse The device fuse is located in the mains connection on the back of the machine Only use 5x20mm 230V 10AT fuses to replace a blown fuse If the ...

Страница 17: ...rt from the machine Apply a thin coat of lubricating oil at the two guide columns 1 Check the rubber cord for handle safeguard 4 replace if it s worn or damaged Every 6 months Check the PERMA lubricating cartridge 2 and replace it if necessary Lubricate the threaded spindle 4 and the spindle shaft with MOLYKOTE BR 2 plus Check that the lock pin of the mixing unit moves smoothly Check that all ball...

Страница 18: ...lus grease 100 g 61298 PERMA long time lubricator cartridge grey screw 12 month 72047 PERMA long time lubricator cartridge red screw 6 month 72063 Spare parts are available under www collomix de 10 Storage disposal 10 1 Storage The storage area should be cool and dry in order to prevent corrosion on the individual parts of the machine The room temperature of the storage area must be constantly abo...

Страница 19: ...ice fuse 10AT Line fuse 16A C RCD Typ B Speed of mixing unit 140UpM Mixing weight max 40kg Container height 120 450mm Container diameter max Ø 365mm Ambient temperature 5 30 C Machine weight 227kg Noise emission in accordance with 2006 42 EG Sound pressure level LpA 64dB re 20µPa Sound power level LWA 75dB re 1pW Uncertainty KpA WA 3dB ...

Страница 20: ...BIAX 45P Collomix GmbH 20 Version 1 7 18 11 2 Dimensions ...

Страница 21: ...Collomix GmbH BIAX 45P Version 1 7 18 21 11 3 Roller conveyor module optional ...

Страница 22: ...rmation from Collomix GmbH Abt Technische Entwicklung Daimlerstr 9 85080 Gaimersheim Deutschland Gaimersheim 2016 04 20 Alexander Essing Managing Director Manufacturer Collomix GmbH Daimlerstr 9 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 IMPORTANT This declaration of conformity will lose its validity if any changes or modifications are made to the machine without the ma...

Страница 23: ...Collomix GmbH BIAX 45P Version 1 7 18 23 ...

Страница 24: ...BIAX 45P Collomix GmbH 24 Version 1 7 18 Collomix GmbH Daimlerstr 9 D 85080 Gaimersheim Germany Tel 49 0 8458 32 98 0 Fax 49 0 8458 32 98 30 www collomix de ...

Отзывы: